Fse-31 Module And Safety Pulse Encoder Related Parameters - ABB ACS880-07 User Manual

Safely-limited speed with the encoder interface (option +q965)
Hide thumbs Also See for ACS880-07:
Table of Contents

Advertisement

44 Option description
Index
Name
SSMx.14
SSM1 output
SAFEIO.55
DO X113:8 diag
pulse on/ off
SAFEIO.72
DO X113:8 logic
state

FSE-31 module and safety pulse encoder related parameters

Set these parameters when you use a safety pulse encoder in the safety application.
Index
Name
200.231
FSE 3X act and par
version
200.232
Number of encoders
S_ENCGEN.01
Safe pulse encoder
version
S_ENCGEN.11
FSE diagnostic fail-
ure reaction
Example value
Description
DO X113:8
Sets the digital output connected to the
SSM1 function.
Active when the motor speed is within the
SSM1 speed limits.
For the option +Q965, ABB has configured
the SSM1 indication signal to this digital
output at the factory.
On
Sets the diagnostic pulse of digital output
X113:8 on or off.
On: The output monitors that it receives test
pulses.
Active high
Sets the logic state of digital output X113:8.
Active high: The digital output is on when
the indicated signal is active.
For the option +Q965, ABB has configured
the SSM1 indication signal to this digital
output at the factory.
Make sure that this value corresponds to
the actual wiring. See the circuit diagrams
of the delivery.
Example value
Description
Version 1
Activates the FSE-31 encoder interface and
shows the version of the encoder parameter
groups (91 and 92).
Single encoder CH1
Shows the number of safety pulse encoders
connected to the FSE-31 module.
Version 1
Activates the safety pulse encoder and
shows the version parameter group S_EN-
CGEN.
STO
Sets the action taken when there is a prob-
lem with the FSE-31 module.
STO: The FSO module goes into Fail-safe
mode and activates the drive STO function.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acs880-17Acs880-17lcAcs880-37Acs880-37lcAcs880

Table of Contents