5 USER GUIDE

5.1 Ethernet

5.1.1 10BASE5 system

In the basic configuration, nodes are connected to a coaxial cable having a maximum length of 500
m as shown in Figure 5-1. Nodes are connected to the coaxial cable via transceiver cables (AUI
cables) and transceivers. Two types of transceivers are available: single-port and multiport
transceivers. Single-port transceivers permit the connection of only one transceiver cable (AUI
cable). Multiport transceivers permit the connection of two or more transceiver cables.
This basic configuration is referred to as a segment, which consists of up to 100 nodes.
MPT
N

Figure 5-1 10BASE5 System Basic Connection Method

500 m maximum
Segment
N
MPT
N
Coaxial cable
:Transceiver cable (AUI cable, 50 m maximum)
:Single-port transceiver
:Multiport transceiver
:Node
:Terminator
(No Repeater Used; Maximum Distance: 500 m)
N
N
5-2