Page 1
Safety Warnings handout topic. Note The Cisco ASR-920-20SZ-M Router power supplies are hot-swappable. If you have installed redundant power supplies, you can replace a single power supply without interrupting power to the router. Caution To avoid erroneous failure messages, allow at least 2 minutes for the system to reinitialize after a power supply has been removed or replaced.
Replace the Power Supply Install the DC Power Supply Procedure Step 1 Before servicing the power supply, switch off the circuit breaker in your equipment area. As an additional precaution, tape the circuit-breaker switch in the Off position. Step 2 Slip on the ESD-preventive wrist strap that was included in the accessory kit.
Replace the Power Supply Remove the AC Power Supply Step 3 Verify that power to the DC circuit connected to the power supply you are installing is off. To ensure that power has been removed from the DC circuits, locate the circuit breakers for the DC circuits, switch the circuit breakers to the OFF position, and tape the circuit-breaker switches in the OFF position.
Replace the Power Supply Install the AC Power Supply Figure 3: Remove the AC Power Supply Caution Do not use the captive installation screw or the power retainer to pull out the power supply. Step 4 Grasp the AC power supply metal tab with one hand, and slide it part of the way out of the chassis. Place your other hand underneath the power supply, and slide it completely out of the chassis.
Page 5
Replace the Power Supply Install the AC Power Supply Figure 4: Install the AC Power Supply Step 4 Tighten the captive installation screw of the power supply. The recommended maximum torque is 5.5 inch-pounds (.62 newton meters). Replace the Power Supply...
Page 6
Replace the Power Supply Install the AC Power Supply Replace the Power Supply...