5-6 Calibration of Key Sensor (MPX70, MARKIII)

The 1-beam continuous sensor on the MPX70 and the MARKIII includes a calibration function. In
most cases it is not necessary to perform calibration after the instrument has left the factory. But cali-
bration does need to be performed whenever the sensor unit is replaced.
To access this feature, select "SENSOR MEASURE" on the SENSOR SHEET menu. You can then
proceed as shown below.
SENSOR MEASURE

5-7 Error History

This feature displays a history of the errors that have occurred, and the number of occurrences.
All models except PRO
*ERROR HISTORY ***
*** DISPLAY ****
PRO
*ERROR HISTORY ***
(–, +,
SENSOR ALL KEY MEASURE
( )
SENSOR ALL KEY MEASURE
WAIT A MOMENT•••
Wait 1~2 minute
SENSOR ALL KEY MEASURE
READING OPEN
SENSOR ALL KEY MEASURE
READING REST
SENSOR ALL KEY MEASURE
READING END
(write
SENSOR ALL KEY MEASURE
NOW WRITING TO FLASH•
Wait 1~2 sec
SENSOR ALL KEY MEASURE
READING COMPLETED OK
OFF
READING
Open: Remove the key stop rail, and lift up
each of the 88 keys once so that the
shutter does not obstruct the sensor
slit beam. (It is not necessary that
this be done simultaneously for all
keys.)
Rest: Put the 88 keys in the rest position.
End: Play each of the 88 keys once, low-
ering them (not too strongly, not too
softly) to the end of the stroke. (A
chromatic scale is sufficient.)
)
SENSOR ONE KEY MEASURE
(>. )
SENSOR ONE KEY MEASURE
SLECT KEY
Press the key that you wish to measure.
SENSOR ONE KEY=XX
(>)
READING OPEN
OPEN
SENSOR ONE KEY=XX
(>)
READING REST
REST
SENSOR ONE KEY=XX
.>)
READING END (write
END
SENSOR ONE KEY=XX
NOW WRITING TO FLASH
SENSOR ONE KEY=XX
COMPLETED OK
Press [PLAY] to open error-message display.
Press [STOP] to display number of occurrences.
Press to clear the error-history memory.
Press
to display the total accumulated running time
(cumulative controller-power ON time).
Press
to display errors and the times at which they
occurred.
Press [+/YES] twice to clear the error-history memory.
II-37
SENSOR MANUAL ADJ
(>. )
SENSOR MANUAL ADJ
SELECT KEY
Press a KEY(ex.41C#)
SENSOR ONE ADJ:K=41C#
(>)
+00 VEL=102 («,»,>,0)
(soft)
SENSOR ONE ADJ:K=41C#
(>)
+03 VEL=102 («,»,>,0)
SENSOR ONE ADJ:K=41C#
.>)
NOW WRITING TO FLASH-
Wait 1~2 minute
SENSOR ONE ADJ:K=41C#
COMPLETED OK
(another KEY)
(>. )
(loud)
(A>)
OFF