Table of Contents

Advertisement

Quick Links

September 18, 2012
Revision 0
Super G3 3rd/4th Line FAX Board-AE1
Service Manual
Product Outline
Technology
Parts Replacing and Cleaning
Error Code
Service Mode
Installation
1
2
3
4
5
6

Advertisement

Table of Contents
loading

Summary of Contents for Canon Super G3 3rd Line FAX Board-AE1

  • Page 1 September 18, 2012 Revision 0 Super G3 3rd/4th Line FAX Board-AE1 Service Manual Product Outline Technology Parts Replacing and Cleaning Error Code Service Mode Installation...
  • Page 2 This manual is copyrighted with all rights reserved. Under the copyright laws, this manual may changes in the contents of this manual over a long or short period, Canon will issue a new not be copied, reproduced or translated into another language, in whole or in part, without the edition of this manual.
  • Page 3 Explanation of Symbols The following rules apply throughout this Service Manual: The following symbols are used throughout this Service Manual. Each chapter contains sections explaining the purpose of specific functions and the Symbols Explanation Symbols Explanation relationship between electrical and mechanical systems with reference to the timing of operation.
  • Page 4: Table Of Contents

    Contents Product Outline Bit Switch Composition ----------------------------------------------------------- 5-5 SSSW-SW01 -------------------------------------------------------------------------------- 5-5 Specifications ------------------------------------------------------------------1-2 SSSW-SW03 -------------------------------------------------------------------------------- 5-6 SSSW-SW04 -------------------------------------------------------------------------------- 5-7 Technology SSSW-SW05 -------------------------------------------------------------------------------- 5-7 Basic Construction ------------------------------------------------------------2-2 SSSW-SW12 -------------------------------------------------------------------------------- 5-8 Overview ----------------------------------------------------------------------------- 2-2 SSSW-SW14 -------------------------------------------------------------------------------- 5-9 Controls --------------------------------------------------------------------------2-3 SSSW-SW24 -------------------------------------------------------------------------------- 5-9 SSSW-SW25 -------------------------------------------------------------------------------5-10 FAX communication control ----------------------------------------------------- 2-3 SSSW-SW26 -------------------------------------------------------------------------------5-10...
  • Page 5 DTMF Transmission Test ----------------------------------------------------------------5-20 V.34 G3 Signal Transmission Test (V34G3Tx) -------------------------------------5-21 Function Test -----------------------------------------------------------------------5-21 4800-bps Signal Transmission Test ---------------------------------------------------5-21 Service Report (REPORT) ------------------------------------------------ 5-22 System Data List ------------------------------------------------------------------5-22 System Dump List ----------------------------------------------------------------5-22 Error Transmission Report ------------------------------------------------------5-23 Installation How to Check this Installation Procedure -------------------------------6-2 When using the parts included in the package ----------------------------- 6-2 Symbols in the illustration -------------------------------------------------------- 6-2 Check Item when Turning OFF the Main Power ----------------------6-2...
  • Page 6 Product Outline ■ Specifications Product Outline Product Outline...
  • Page 7: Product Outline Specifications

    Recording unit maximum reception size: A3 (297 mm x 420 mm) scanning line density: 600 dpi x 600 dpi Memory image memory: 3700 prints (Canon Fax Standard Chart No.1): memory type: hard disk (image area of 6.4 GB) storage: JBIG...
  • Page 8: Technology

    Technology ■ Basic Construction ■ Controls Technology Technology...
  • Page 9: Overview

    Technology Technology > Basic Construction > Overview Basic Construction Overview This product is a FAX unit for adding FAX lines to the machine. This machine is equipped with a telephone-based communication function and an image processing function to enable a digital copier to serve as a highly functional multi-function fax machine.
  • Page 10: Controls

    Technology Technology > Controls > FAX communication control Controls Connection of the PCB for the FAX unit with 2 line and Connection of the PCB for the FAX unit with 3/4 line Copier FAX unit for one line FAX communication control In the FAX unit for 1 line, the main controller in the machine controls the G3 FAX PCB in the Main controller 1 Modular PCB...
  • Page 11: Parts Replacing And Cleaning

    Parts Replacing and Cleaning ■ Parts Replacing and Cleaning Parts Replacing and Cleaning Parts Replacing and Cleaning...
  • Page 12: Removing From The Host Machine

    Parts Replacing and Cleaning Parts Replacing and Cleaning > Parts Replacing and Cleaning > Removing from the Host Machine > G3 FAX Unit Parts Replacing and Cleaning 4) Remove the Telephone Cord [1]. Removing from the Host Machine ■ G3 FAX Unit 1) Open the Right Lower Cover [1].
  • Page 13 Parts Replacing and Cleaning Parts Replacing and Cleaning > Parts Replacing and Cleaning > Removing from the Host Machine > G3 FAX Unit 6) Remove the Reader Communication Cable [1] if the Reader is installed. 8) Remove the Rear Cover [1]. •...
  • Page 14 Parts Replacing and Cleaning Parts Replacing and Cleaning > Parts Replacing and Cleaning > Removing from the Host Machine > G3 FAX Unit 10) Remove the G3 FAX Unit Connector [1]. 12) Remove the G3 FAX Unit [1]. • 4 Screws [2] •...
  • Page 15: External Cover

    Parts Replacing and Cleaning Parts Replacing and Cleaning > Parts Replacing and Cleaning > Electrical System > Removing the Modular PCB External Cover Electrical System ■ Removing the FAX Unit Cover ■ Removing the Modular PCB <Preparation> <Preparation> 1) Remove the G3 FAX Unit. 1) Remove the G3 FAX Unit.
  • Page 16: Removing The G3 Fax Expansion Pcb

    Parts Replacing and Cleaning Parts Replacing and Cleaning > Parts Replacing and Cleaning > Electrical System > Removing the G3 FAX Expansion PCB 2) Remove the Modular PCB [1]. ■ Removing the G3 FAX Expansion PCB • 1 Wire Saddle [2] <Preparation>...
  • Page 17: Error Code

    Error Code ■ Overview ■ User Error Code ■ Service Error Code Error Code...
  • Page 18 Error Code > Overview > Guide to Error Code Overview • Provide a remedy against echoes. Change the following bit setting for service data #1 SSSW SW03: Bit4 -> 1: to cause the machine to ignore the first DIS signal from the other party. Guide to Error Code ->...
  • Page 19 Error Code > Service Error Code User Error Code Service Error Code Description Description #001 an original has jammed. ##100 at time of transmission, the procedural signal has been transmitted more than specified. #003 T/R time-out for copying or sending/receiving a single page has occurred. #005 T/R time-out for initial identification (T0/T1) has occurred.
  • Page 20 Error Code > Service Error Code Description Description ##670 at time of V.8 late start, the V.8 ability of DIS front the receiving party is expected to be ##773 at time of ECM transmission, the procedural signal has been transmitted more than detected, and the CI signal is expected to be transmitted in response;...
  • Page 21: Service Mode

    Service Mode ■ Outline ■ Setting of Bit Switch (SSSW) ■ Setting of Menu Switch (MENU) ■ Setting of Numeric Parameter (NUMERIC Param.) ■ Setting of Destination (TYPE) ■ Setting of Printer Functions (PRINTER) ■ Initialization of Set Value (CLEAR) ■...
  • Page 22: Service Mode Composition

    Service Mode Service Mode > Outline > Using Service Mode Outline Using Service Mode 1) Press the User Mode key " " on the control panel. Service Mode Composition 2) Press the keys 2 and 8 on the keypad at the same time. 3) Press the User Mode key "...
  • Page 23: Menu Items

    Service Mode Service Mode > Outline > Menu Items Menu Items For instance, in the case of #1 SSSW, the following holds true; key functions and operations are the same for all screens: #1 SSSW SW01 error management Menu Num Ncu Type ISDN Sssw Print Clear Test...
  • Page 24 Service Mode Service Mode > Outline > Menu Items #3 NUM not used #8 CLEAR RTN transmission condition (1) USSW SW RTN transmission condition (2) SRV SW RTN transmission condition (3) NCC pause time (before ID code) SRV DATA REPORT NCC pause time (after ID code) pre-pulse time at time of call COUNTER...
  • Page 25: Setting Of Bit Switch (Sssw)

    Service Mode Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW01 Setting of Bit Switch (SSSW) ■ SSSW-SW01 ● Functional Construction Bit Switch Composition Function 0 service error code output not output The registration/setup items of the switch are set according to the positions of its 8 bits. 1 error dump list output not output...
  • Page 26: Sssw-Sw03

    Service Mode Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW03 ■ SSSW-SW03 Detailed Discussions of Bits 4, 5, and 6 Use it to select an appropriate transmission mode: international transmission (1), international ● Functional Construction transmission (2), or international transmission (3).
  • Page 27: Sssw-Sw04

    If errors occur frequently at time of reception because of the condition of the line, select 'high be used for communications from non-Canon machines. speed' for reception mode and, at the same time, selects 'do not receive' for 'ECM reception.'...
  • Page 28: Sssw-Sw12

    Service Mode Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW12 ■ SSSW-SW12 The machine will stop the ongoing communication if the transmission/reception of a single original page takes 32 min or more. To use the timer for a purpose other than this function, ●...
  • Page 29: Sssw-Sw14

    Service Mode Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW24 ■ SSSW-SW14 ■ SSSW-SW24 ● Functional Construction ● Functional Construction Function Function 0 not used 0 PIN CODE function 1 not used 1 Forced PIN CODE function 2 direction of scanning for inch/mm both main and sub sub scanning direction...
  • Page 30: Sssw-Sw25

    Service Mode Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW26 5-10 ■ SSSW-SW25 ■ SSSW-SW26 ● Functional Construction ● Functional Construction Function Function 0 transmission telephone number indicated report other party's caller's 0 not used 1 not used 1 not used 2 not used...
  • Page 31: Sssw-Sw28

    Service Mode Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW28 5-11 ■ SSSW-SW28 Detailed Discussions of Bit 3 Select whether to inform the existence of the V.8 procedure with the DIS signal that is ●...
  • Page 32: Sssw-Sw30

    Service Mode Service Mode > Setting of Bit Switch (SSSW) > Bit Switch Composition > SSSW-SW30 5-12 ■ SSSW-SW30 Caution: ● Functional Construction Be sure to switch the following switches when switching the switch. • In case setting the switch as 1 (new detection method): Function 0 not used /* DIAL TONE01 */ B11000001...
  • Page 33: Setting Of Menu Switch (Menu)

    Service Mode Service Mode > Setting of Menu Switch (MENU) > Menu Switch Composition 5-13 Setting of Menu Switch (MENU) 006: Telephone Line Monitor Use it to the telephone line monitor function: 0 (DIAL): generate the monitor sound of the telephone line using the speaker from the start of Menu Switch Composition transmission to DIS.
  • Page 34: Setting Of Numeric Parameter (Numeric Param.)

    Service Mode Service Mode > Setting of Numeric Parameter (NUMERIC Param.) > Numerical Parameter Composition 5-14 Setting of Numeric Parameter (NUMERIC Param.) 002: RTN transmission condition (1) 003: RTN transmission condition (2) 004: RTN transmission condition (3) Numerical Parameter Composition Use it to set RTN signal transmission conditions.
  • Page 35: Setting Of Destination (Type)

    Service Mode Service Mode > Setting of Destination (TYPE) > Overview 5-15 Setting of Destination (TYPE) 010: line connection identification length Use it to set the time for identifying the line connection. Raise this parameter if errors occur frequently at time of communication because of the Overview condition of the line.
  • Page 36: Setting Of Printer Functions (Printer)

    Service Mode Service Mode > Setting of Printer Functions (PRINTER) > Setting of Bit Switch (SSSW) > SSSW-SW06 5-16 Setting of Printer Functions (PRINTER) ■ SSSW-SW06 ● Functional Construction Setting of Bit Switch (SSSW) Function not used ■ SSSW-SW05 not used not used ●...
  • Page 37: Setting Of Numeric Parameter (Numeric Param.)

    Service Mode Service Mode > Initialization of Set Value (CLEAR) > Overview 5-17 Setting of Numeric Parameter (NUMERIC Param.) Initialization of Set Value (CLEAR) Overview Sssw Menu Num Ncu Type ISDN Print Clear Test Report <NUM> <READY> <1/4> You can select and initialize data by making the following selections; as a result, settings and ←(yyyyy){aaaaa~bbbbb} xxxxx various parameter values will be reset to the factory settings.
  • Page 38: Test Mode (Test)

    Service Mode Service Mode > Test Mode (TEST) > Outline > Test Mode Construction 5-18 Test Mode (TEST) The following table shows text mode items that are valid and invalid when a fax board is installed: Yes: may be used Outline -: not used Level 1...
  • Page 39: Modem Test

    Service Mode Service Mode > Test Mode (TEST) > MODEM Test > Frequency Test (FREQ) 5-19 MODEM Test ■ Frequency Test (FREQ) Of the items indicated below, press one; in response, the DC circuit will be closed and the ■ Relay Test (RELAY-1) selected frequency will be transmitted using the tone transmission function of the modem.
  • Page 40: G3 Signal Transmission Test (G3

    Service Mode Service Mode > Test Mode (TEST) > MODEM Test > DTMF Transmission Test 5-20 ■ G3 Signal Transmission Test (G3 Tx) Caution: Of the items indicated below, press one. In response, the DC circuit will be closed and the '300-ALL0' through '300-4:1' are not currently supported.
  • Page 41: G3 Signal Transmission Test (V34G3Tx)

    Service Mode Service Mode > Test Mode (TEST) > Function Test > 4800-bps Signal Transmission Test 5-21 Function Test ■ V.34 G3 Signal Transmission Test (V34G3Tx) Select the transmission speed you want to test, and then select a modulation speed (baud ■...
  • Page 42: Service Report (Report)

    Service Mode Service Mode > Service Report (REPORT) > System Dump List 5-22 Service Report (REPORT) System Dump List System Data List NOTE: A system dump list is generated when you execute the following in service mode: FAX> Report> DUMP. Use it to check the settings associated with the service soft switch and service parameters.
  • Page 43: Error Transmission Report

    Service Mode Service Mode > Service Report (REPORT) > Error Transmission Report 5-23 Error Transmission Report It provides error information on the 3 most recent communications. 2003 09/02 TUE 12:00 An error transmission report is an error transmission report together to which a service error #1 LATEST #000 START TIME...
  • Page 44: Installation

    Installation ■ How to Check this Installation Procedure ■ Check Item when Turning OFF the Main Power ■ Installation Outline Drawing ■ Checking the Contents ■ Installation Procedure Installation Installation...
  • Page 45: When Using The Parts Included In The Package

    Installation Installation > Installation Outline Drawing How to Check this Installation Procedure Check Item when Turning OFF the Main Power Check that the main power switch is OFF. When using the parts included in the package 1) Turn OFF the main power switch of the host machine. 2) Be sure that Control Panel Display and Main Power Lamp are both turned OFF, and then A symbol is described on the illustration in the case of using the parts included in the package disconnect the power plug.
  • Page 46: Checking The Contents

    Installation Installation > Checking the Contents Checking the Contents NOTE: Install this equipment after installing the Super G3 FAX Board and Super G3 2nd Line Fax Board. [10] F-6-4 Installation Installation > Checking the Contents...
  • Page 47 Installation Installation > Checking the Contents Parts to be used differs depending on models; thus, refer to the following table. Part Name Number iR-ADV C5051/C5045/ iR-ADV C9075 PRO/C9070 iR-ADV 6075/6065/6055 Series, iR-ADV 4051/4045/4035/4025 C5035/C5030 Series PRO/C9065 PRO/C9060 PRO iR-ADV 8105/8095/8085 Series Series Series, iR-ADV C7065/C7055 Series...
  • Page 48: Installation Procedure

    Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C5051/C5045/C5035/C5030 Series) Installation Procedure 4) Remove the Ttelephone Cord [1]. Installation Procedure (iR-ADV C5051/C5045/C5035/ C5030 Series) 1) Open the Right Lower Cover [1]. (Open also the Right Upper Cover in the same time). F-6-7 5) Remove the Left Rear Cover [1].
  • Page 49 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C5051/C5045/C5035/C5030 Series) 6) Remove the Reader Communication Cable [1] if the Reader is installed. 8) Remove the Rear Cover [1]. • 2 Rubbers Caps [2] • 2 Screws [3] • Hook in 1 place [4] F-6-9 7) Remove the Left Rear Sub Cover [1].
  • Page 50 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C5051/C5045/C5035/C5030 Series) 10) Disconnect the Connector [1] of the G3FAX Unit. 12) Remove the G3FAX Unit [1]. • 4 Screws [2] • Hook in 2 place [3] F-6-13 11) Remove the Connector of USB [1]. F-6-15 F-6-14 Installation...
  • Page 51 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C5051/C5045/C5035/C5030 Series) 13) Remove the Cover [1] of G3FAX Unit. 15) Align the Connector [2] on the G3FAX Expansion PCB [1] with the Connector [3] on the • 6 Screws [2] G3FAX Control PCB, and install.
  • Page 52 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C5051/C5045/C5035/C5030 Series) 17) Install the Cover for G3FAX Unit. 20) Install the Connector [1] of G3FAX Unit. 18) Install the G3FAX Unit. 21) Install the Connector [1] of Speaker Cables (Yellow). 19) Install the Connector of USB.
  • Page 53: Installation Procedure (Ir-Adv C9075 Pro/C9070 Pro/C9065 Pro/ C9060 Pro Series, Ir-Adv C7065/C7055 Series)

    Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C9075 PRO/C9070 PRO/C9065 PRO/C9060 PRO Series, iR-ADV C7065/C7055 Series) > Removing 6-10 Installation Procedure (iR-ADV C9075 PRO/C9070 23) Put applicable Modular Label [1] on the position shown in the figure. PRO/C9065 PRO/C9060 PRO Series, iR-ADV C7065/ C7055 Series) NOTE: In the model without the reader unit, the step of disconnecting/connecting the leader...
  • Page 54 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C9075 PRO/C9070 PRO/C9065 PRO/C9060 PRO Series, iR-ADV C7065/C7055 Series) > Removing 6-11 2) Put the Reader Power Supply Cable [1] through the hole [2] of the Box Cover (Left), and 3) Free the Speaker Cable [1] from the 2 Wire Saddles [2], and disconnect the 2 connectors [3]. remove the Box Cover (Left) [3].
  • Page 55 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C9075 PRO/C9070 PRO/C9065 PRO/C9060 PRO Series, iR-ADV C7065/C7055 Series) > Removing 6-12 5) Remove the Cover Support Plate [1]. 7) Remove the FAX Unit [1]. • 2 Screws [2] • 2 Screws [2] (The removed screws will be used in step 14.) F-6-28 F-6-30 6) Remove the Speaker Cable [1], the FAX Unit Cable [2] and the USB Cable [3] from the 2...
  • Page 56: Installing The Super G3 3Rd/4Th Line Fax Board

    Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C9075 PRO/C9070 PRO/C9065 PRO/C9060 PRO Series, iR-ADV C7065/C7055 Series) > Installing th 6-13 9) Intall the 2 Spacers [1] and the 2 screws (TP; M3x6) [2] to the FAX Board (2-Line). 12) Fit the connector [2] of the G3FAX Expansion PCB [1] to the connector [3] on the FAX Board (2-Line), and install the PCB.
  • Page 57 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C9075 PRO/C9070 PRO/C9065 PRO/C9060 PRO Series, iR-ADV C7065/C7055 Series) > Installing th 6-14 14) Install the FAX Unit [1] by aligning the protrusion [B] on the FAX Unit to the rail [A] on the 15) Secure the Speaker Cable [1], the FAX Unit Cable [2] and the USB Cable [3] with the 2 host machine.
  • Page 58 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV C9075 PRO/C9070 PRO/C9065 PRO/C9060 PRO Series, iR-ADV C7065/C7055 Series) > Installing th 6-15 19) Install the Box Cover (Left). 23) Insert one end of the Telephone Cord [1] included in the package to the Modular Jack [2] 20) Affix the FAX MJ Label [1].
  • Page 59: Installation Procedure (Ir-Adv 6075/6065/6055 Series, Ir-Adv 8105/8095/8085 Series)

    Installation Installation > Installation Procedure > Installation Procedure (iR-ADV 6075/6065/6055 Series, iR-ADV 8105/8095/8085 Series) 6-16 Installation Procedure (iR-ADV 6075/6065/6055 Series, 24) Affix the FAX Approval Label [1] on the position shown in the figure. iR-ADV 8105/8095/8085 Series) NOTE: This step is only for Taiwan. 1) Free the Reader Communication Cable [1] and Reader Power Supply Cable [2] from the 2 Wire Saddles [1].
  • Page 60 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV 6075/6065/6055 Series, iR-ADV 8105/8095/8085 Series) 6-17 3) Remove the Rear Upper Cover [1]. 5) Install the G3 FAX Expansion PCB [1]. • 4 Screws (RS Tightening) [2] • 1 Connector [2] •...
  • Page 61 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV 6075/6065/6055 Series, iR-ADV 8105/8095/8085 Series) 6-18 7) Install the Rear Upper Cover. 9) Remove the 2 Dust Covers [1]. NOTE: Be sure to install the 3 TP screws show in the figure below. F-6-51 F-6-49 10) Connect the PTT Plug [1] matched the field or area to the PTT Cable (6 contact type).
  • Page 62: Installation Procedure (Ir-Adv 4051/4045/4035/4025 Series)

    Installation Installation > Installation Procedure > Installation Procedure (iR-ADV 4051/4045/4035/4025 Series) 6-19 Installation Procedure (iR-ADV 4051/4045/4035/4025 11) Affix the following FAX Approval Label [1]. Series) NOTE: This step is only for Taiwan. 1) Remove the Ttelephone Cord. 2) Remove the Rear Cover. •...
  • Page 63 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV 4051/4045/4035/4025 Series) 6-20 7) Free the cable from the Wire Saddle. 4) Free the cable from the 2 Wire Saddles, and disconnect the connector. 5) Free the cable from the Edge Saddle. Connector Wire Saddle Edge Saddle...
  • Page 64 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV 4051/4045/4035/4025 Series) 6-21 9) Install the 3 PCB Spacers. 11) Install the G3 FAX Expansion PCB. • 1 Connector • 2 Resin Spacers • 3 Screws (TP; M3x6) CAUTION: When installing the G3 FAX Expansion PCB, check that the connector is connected properly.
  • Page 65 Installation Installation > Installation Procedure > Installation Procedure (iR-ADV 4051/4045/4035/4025 Series) 6-22 13) Connect the 3 connectors disconnected in step 8, and return the Wire Saddle to its 16) Return the removed covers to their original positions. original position. • Left Rear Cover (4 Screws) 14) Free the cable from the Edge Saddle, and install the cover of the Line Expansion Kit (2- •...
  • Page 66: Checking The Operation

    Installation Installation > Installation Procedure > Checking the Operation > Basic Settings 6-23 Checking the Operation 20) Affix the following FAX Approval Label . ■ Type Settings NOTE: This step is only for Taiwan. Select the country/region of the FAX Board in Service Mode: FAX> TYPE> TYPE This setting performs the parameter settings to match the communication specification of the country/ region.
  • Page 67: Fax Communication Test

    Installation Installation > Installation Procedure > Checking the Operation > FAX communication test 6-24 ■ FAX communication test Perform communication test to check if FAX function works correctly. 1) Switch the control panel display to Fax display. 2) Select the sending line. Press [Fax]>...

This manual is also suitable for:

Super g3 4th line fax board-ae1

Table of Contents