ViewSonic PJ658 User Manual page 61

Viewsonic lcd projector user guide
Hide thumbs Also See for PJ658:
Table of Contents

Advertisement

Regarding the indicator lamps (continued)
LAMP
POWER
indica-
indicator
tor
Blinking
In
Red
Turned
or
off
Lighting
In
Red
Blinking
In
Red
Turned
or
off
Lighting
In
Red
Lighting
Simultaneous
In
Green
blinking in
Lighting
In
Green
blinking in
NOTE • When the interior portion has become overheated, for safety
purposes, the power source is automatically turned off, and the indicator lamps
may also be turned off. In such a case, press the "" (OFF) side of the power
switch, and wait at least 45 minutes. After the projector has sufficiently cooled
down, please make confirmation of the attachment state of the lamp and lamp
cover, and then turn the power on again.
ViewSonic
TEMP
indica-
tor
The cooling fan is not operating.
Please turn the power off, and allow the projector to
cool down at least 20 minutes. After the projector has
Blinking
sufficiently cooled down, please make confirmation
In
Red
that no foreign matter has become caught in the fan,
etc., and then turn the power on again.
If the same indication is displayed after the remedy,
please contact your dealer or service company.
There is a possibility that the interior portion
has become heated.
Please turn the power off, and allow the projector to
cool down at least 20 minutes. After the projector has
sufficiently cooled down, please make confirmation of
Lighting
the following items, and then turn the power on again.
In
Red
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the remedy,
please set FAN SPEED of the SERVICE item in the
OPTION menu to HIGH.
It is time to clean the air filter.
Please immediately turn the power off, and clean or
change the air filter referring to the section "Air Filter".
Red
After cleaning or changing the air filter, please be sure
to reset the filter timer. After the remedy, reset the
power to ON.
There is a possibility that the interior portion
has become overcooled.
Alternative
Please use the unit within the usage temperature pa-
Red
rameters (5°C to 35°C). After the treatment, reset the
power to ON.
PJ658
Troubleshooting
Description
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pj658 vs11361Vs11361

Table of Contents