HIKVISION DS-K2600 Series Quick Start Manual
Hide thumbs Also See for DS-K2600 Series:

Advertisement

DS-K2600 Series
Access Controller
Quick Start Guide
UD.6L0206D1052A01

Advertisement

Table of Contents
loading

Summary of Contents for HIKVISION DS-K2600 Series

  • Page 1 DS-K2600 Series Access Controller Quick Start Guide UD.6L0206D1052A01...
  • Page 2 (hereinafter referred to be “Hikvision”). This user manual (hereinafter referred to be “the Manual”) cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision. Unless otherwise stipulated, Hikvision does not make any warranties, guarantees or representations, express or implied, regarding to the Manual.
  • Page 3 AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS.
  • Page 4 DS-K2600 Serial Access Controller Regulatory Information FCC Information FCC compliance: This equipment has been tested and found to comply with the limits for a digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 5 DS-K2600 Serial Access Controller 2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).
  • Page 6 DS-K2600 Serial Access Controller Preventive and Cautionary Tips Before connecting and operating your device, please be advised of the following tips: • Ensure unit is installed in a well-ventilated, dust-free environment. • Keep all liquids away from the device. • Ensure environmental conditions meet factory specifications.
  • Page 7 DS-K2600 Serial Access Controller Do not install, wiring, or uninstall when the power is still on. To reduce the risk of fire or electrical shock, do not expose this product to rain or moisture. This installation should be made by a qualified service person and should conform to all the local codes.
  • Page 8: Table Of Contents

    DS-K2600 Serial Access Controller Table of Contents CHAPTER 1 PRODUCT DESCRIPTION..............3 ...................... 3 VERVIEW ..................3 RODUCT UNCTION CHAPTER 2 APPEARANCE..................5 ................5 OMPONENT ESCRIPTION 2.1.1 Access Controller Component Schematic Diagram.........5 CHAPTER 3 TERMINAL CONNECTION..............7 ...................7 ERMINALS ESCRIPTION 3.1.1 DS-K2601Terminal Description............... 7 3.1.2 DS-K2602Terminal Description.............
  • Page 9 DS-K2600 Serial Access Controller ................24 ONNECTING OWER UPPLY ..............25 RMING EGION NPUT ERMINAL 4.9.8 Connecting Normally Open Detector............ 25 4.9.9 Connecting Normally Closed Detector..........25 CHAPTER 5 SETTINGS..................26 ................26 NITIALIZING THE ARDWARE NO/NC..................26 ELAY NPUT 5.2.1 Lock Relay Output................. 26 5.2.2 Alarm Relay Output Status..............
  • Page 10: Chapter 1 Product Description

    DS-K2600 Serial Access Controller Chapter 1 Product Description 1.1 Overview DS-K2600 is a powerful and stable access controller, using the logical architecture design. DS-K2600 is designed with TCP/IP network interface and its signal processed with special encryption and can be run offline. Anti-tampering function is also supported. 1.2 Product Function ...
  • Page 11 DS-K2600 Serial Access Controller  Supports various card types as normal/ disabled/ blacklist/ patrol/ guest/ duress/ super card, etc.;  Various indicators to show different status;  Supports time synchronization via NTP, manual or automatic method;  Supports record storage function when it is offline and insufficient storage space storage alarm function;...
  • Page 12: Chapter 2 Appearance

    DS-K2600 Serial Access Controller Chapter 2 Appearance 2.1 Component Description Access Controller Component Schematic Diagram Take DS-K2604 as an example, the component schematic diagram is shown below. Figure 2-1 DS-K2604 Component Schematic Diagram...
  • Page 13 DS-K2600 Serial Access Controller Table 2-1 DS-K2600 Component Description Component Description DS-K2601 DS-K2602 DS-K2604 Alarm Relay Output Status (NC/NO) Network Data Indicator RS-485 Communication Indicator Network Status Indicator Door Relay Output Status (NC/NO) Choice Battery Charging Indicator Power Indicator Charging Completing Indicator Running Indicator Hardware Initialization and Normal Working Choice...
  • Page 14: Chapter 3 Terminal Connection

    DS-K2600 Serial Access Controller Chapter 3 Terminal Connection 3.1 Terminals Description DS-K2601Terminal Description Figure 3-1DS-K2601 Terminals...
  • Page 15 DS-K2600 Serial Access Controller Table 3-1 DS-K2601 Terminal Description DS-K2601 Grounding Lock Power +12V Power Output of the Lock Grounding Card Reader Power +12V Power Output of the Head Read Grounding Weigand Head Read Data Input Data0 Weigand Head Read Data Input Data1 Weigand Card Reader Buzzer Control Output Card Reader...
  • Page 16 DS-K2600 Serial Access Controller DS-K2601 Arming Region Access Terminal 4 (Only for Linkage of Alarm Relay Output) E-Lock Door 1 Door Relay Input (Dry Contact) Door Door 1 Door Contact Detector Input Contact Grounding Input Door Open Door 1 Door Open Button Input Button Grounding +12V...
  • Page 17: Ds-K2602Terminal Description

    DS-K2600 Serial Access Controller DS-K2601 Output COM1 NO/NC2 Alarm Relay 2 Output (Dry Contact) COM2 Event Alarm Input 2 Event Input Grounding Event Alarm Input 1 DS-K2602Terminal Description Figure 3-2 DS-K2602 Terminal Description...
  • Page 18 DS-K2600 Serial Access Controller Table-3-2 DS-K2602 Terminal Description DS-K2602 Grounding Power for E-Lock +12V Power Output of the Lock Power for Grounding Card +12V Power Output of the Head Read Reader Grounding Weigand Head Read Data Input Data0 Weigand Head Read Data Input Data1 Weigand Card Reader Buzzer Control Output Card...
  • Page 19 DS-K2600 Serial Access Controller DS-K2602 (Valid Card Output) Grounding Weigand Head Read Data Input Data0 Weigand Head Read Data Input Data1 Weigand Card Reader Buzzer Control Output Card Indicator of Card Reader Control Output Reader 1 (Invalid Card Output) Indicator of Card Reader Control Output (Valid Card Output) Arming Region Access Terminal 1 (Only for Linkage of Alarm Relay Output)
  • Page 20 DS-K2600 Serial Access Controller DS-K2602 +12V DC12V Cathode Power Grounding BAT+ DC12V Battery Cathode Battery BAT- DC12V Battery Anode Card Reader RS485+ Access 485A+ RS 485A- Card Reader RS485- Access Card Grounding Reader 485 Interface Card Reader RS485+ 485B+ RS 485B- Card Reader RS485- Grounding 485C+...
  • Page 21: Ds-K2604 Terminal Description

    DS-K2600 Serial Access Controller DS-K2602 Grounding Event Alarm Input3 Event Alarm Input 2 Grounding Event Alarm Input 1 DS-K2604 Terminal Description Figure 3-3 DS-K2604 Access Controller Terminals Table 3-3 DS-K2604 Port Description...
  • Page 22 DS-K2600 Serial Access Controller DS-K2604 Power Grounding Supply of Power Supply of E-Lock Output +12V E-Lock Grounding Power Supply of Power Supply of Card Reader Output +12V Card Reader Grounding Weigand Card Reader Data Input Data0 Weigand Card Reader Data Input Data1 Weigand Buzzer of Card Reader Control Output Card Reader...
  • Page 23 DS-K2600 Serial Access Controller DS-K2604 Grounding Weigand Card Reader Data Input Data0 Weigand Card Reader Data Input Data1 Buzzer of Card Reader Control Output Weigand Card Reader Cresset of Card Reader Control Output (Invalid Card Output) Cresset of Card Reader Control Output (Valid Card Output) Arming Region Access Terminal 1 (Only for Linkage of Alarm Relay Output)
  • Page 24 DS-K2600 Serial Access Controller DS-K2604 Magnetics Signal Grounding Input Door 2 Magnetic Detector Input Door 3 Magnetic Detector Input Signal Grounding Door 4 Magnetic Detector Input Door 1 Door Button Input Signal Grounding Door 2 Door Button Input Door Button Door 3 Door Button Input Signal Grounding Door 4 Door Button Input...
  • Page 25 DS-K2600 Serial Access Controller DS-K2604 NO/NC1 Alarm Relay 1 Output (Dry Contact) COM1 NO/NC2 Alarm Relay 2 Output (Dry Contact) Alarm COM2 Output NO/NC3 Alarm Relay 3 Output (Dry Contact) COM3 NO/NC4 Alarm Relay 4 Output (Dry Contact) COM4 Event Alarm Input 8 Grounding Event Alarm Input 7 Event Alarm Input 6...
  • Page 26: Chapter 4 Card Reader Installation

    DS-K2600 Serial Access Controller Chapter 4 Card Reader Installation External Terminal DS-K2601 External Terminals Figure 4-2 DS-K2601 External Terminals DS-K2602 External Terminals Figure 4-3 DS-K2602 External Terminals DS-K2604 External Terminals Figure 4-4 DS-K2604 External Terminals...
  • Page 27: Card Reader Installation

    DS-K2600 Serial Access Controller 4.2 Card Reader Installation 4.3 Card Reader Installation The Connection of Weigand Card Reader Figure 4-5 Wiring diagram of Wiegand card reader Note: You must connect the OK/ERR/BZ, if using access controller to control the LED and buzzer of the Wiegand card reader.
  • Page 28: Rs485 Card Reader Connection

    DS-K2600 Serial Access Controller RS485 Card Reader Connection Figure 4-6 Wiring diagram of RS485...
  • Page 29: Installing E-Lock

    DS-K2600 Serial Access Controller 4.4 Installing E-Lock Installation of Cathode Lock Figure 4-7 Wiring diagram of cathode lock Installation of Anode Lock Figure 4-8 Wiring diagram of anode lock...
  • Page 30: Connecting The External Alarm Device

    DS-K2600 Serial Access Controller 4.5 Connecting the External Alarm Device Figure 4-9 External Alarm Device Connection 4.6 Door Button Wiring Diagram Figure 4-10 Power Button Connection...
  • Page 31: The Connection Of Magnetics Detection

    DS-K2600 Serial Access Controller 4.7 The Connection of Magnetics Detection Figure 4-11 Magnetics Connection 4.8 Connecting Power Supply Figure 4-12 Power Supply Connection...
  • Page 32: Arming Region Input Terminal

    DS-K2600 Serial Access Controller 4.9 Arming Region Input Terminal Connecting Normally Open Detector Figure 4-13 Normally Open Status Connecting Normally Closed Detector Figure 4-14 Normally Closed Status...
  • Page 33: Settings

    DS-K2600 Serial Access Controller Chapter 5 Settings 5.1 Initializing the Hardware Steps: The jumper cap jumps from Normal to Initial. Disconnect the power and restart the access controller, the controller buzzer buzzes a long warning. After the buzzer stops, jump the jumper cap back to Normal. Disconnect the power and restart the access controller.
  • Page 34: Alarm Relay Output Status

    DS-K2600 Serial Access Controller Figure 5-2 Normally Open Status Lock Relay Normally Closed Status Figure 5-3 Normally Closed Status Alarm Relay Output Status Alarm Relay Output Normally Open...
  • Page 35 DS-K2600 Serial Access Controller Figure 5-4 Alarm Relay Output Normally Open Alarm Relay Output Normally Closed Figure 5-5 Normally Closed Status Work Flow of Software For detailed information, please see the user manual of the client software. Refer to the following work flow:...
  • Page 36 DS-K2600 Serial Access Controller Figure 6-1 Software Client Work Flow...
  • Page 37: Activating The Control Panel

    DS-K2600 Serial Access Controller Chapter 6 Activating the Control Panel Purpose: You are required to activate the control panel first before you can use the control panel. Activation via SADP, and Activation via client software are supported. 6.1 Activation via SADP Software SADP software is used for detecting the online device, activating the device, and resetting the password.
  • Page 38 DS-K2600 Serial Access Controller 3. Create a password and input the password in the password field, and confirm the password. STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
  • Page 39: Activation Via Client Software

    DS-K2600 Serial Access Controller either modifying the IP address manually or checking the checkbox of Enable DHCP. 6. Input the password and click the Save button to activate your IP address modification. 6.2 Activation via Client Software The client software is versatile video management software for multiple kinds of devices.
  • Page 40 DS-K2600 Serial Access Controller Click the icon on the upper-left side of the page, select Access Control to enter the control panel. Click the Controller Management icon to enter the Controller Management interface, as shown in the figure below.
  • Page 41 DS-K2600 Serial Access Controller Check the device status from the device list, and select an inactive device. Click the Activate button to pop up the Activation interface. Create a password and input the password in the password field, and confirm the password.
  • Page 42 DS-K2600 Serial Access Controller STRONG PASSWORD RECOMMENDED– We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product.
  • Page 43: Specification

    DS-K2600 Serial Access Controller Specification Module DS-K2601 DS-K2602 DS-K2604 Power DC 12V/1A Processor 32bit Capacity Uplink Communication TCP/IP Interface, andRS-485 Interface Interface Downlink Communication RS-485 and Wiegand Interface Normal Card/ 100,000 normal card and 300,000 card wiping logs Event Log LED Indicators Power Status, Communication Status, Exception Status Embedded Timer...
  • Page 44 DS-K2600 Serial Access Controller Module DS-K2601 DS-K2602 DS-K2604 Humidity Dimension 370mm(L)*345mm(w)*90mm(H) Table 6-1 DS-K2600 Specification...
  • Page 45 DS-K2600 Serial Access Controller...

This manual is also suitable for:

Ds-k2601Ds-k2602Ds-k2604

Table of Contents