Power Connection

Electrocution or fire can occur
if machine is ungrounded,
incorrectly connected to
power, or connected to an
undersized circuit. Use an
electrician or a qualified ser-
vice personnel to ensure a
safe power connection.
Before the machine can be connected to the
power source, an electrical circuit must be made
available that meets the minimum specifications
given in Circuit Requirements on Page 15. If
a power circuit has not been prepared for the
machine, do that now. To ensure a safe and code-
compliant setup, we strongly recommend that all
electrical work be done by an electrician or quali-
fied service personnel.
Model G0895 Power Connection
Insert plug into a matching NEMA receptacle (see
Figure 27). The machine is now connected to the
power source.
L6-30 GROUNDED
LOCKING
RECEPTACLE
Grounding Prong
is Hooked
L6-30
LOCKING
PLUG
Current Carrying Prongs
Figure 27. Typical L6-30 plug and receptacle.
Model G0895 (Mfd. Since 01/20)
Vacuum Pump Power Connection
Move the disconnect switch handle to the ON
position, as illustrated below. The machine is now
connected to the power source.
Figure 28. Connecting power to machine.
Move the disconnect switch handle to the OFF
position, as illustrated below. The machine is now
disconnected from the power source.
Note: Lock the switch in the OFF position to
restrict others from starting the machine.