Acquisition Of Mode Setting Value For Ink Low Signal (Input); Acquisition Of Mode Setting Value For Ink Cartridge Exchange Signal (Input) - Epson CW-C6000 Series Technical Reference Manual

External i/o
Hide thumbs Also See for CW-C6000 Series:
Table of Contents

Advertisement

Acquisition of mode setting value for ink low signal (input)

[Format]
~H(CNA,J
[Parameter] None
[Function]
This acquires the mode setting value for the ink low signal.
Return value after
executing this command
D/0
1
E/2

Acquisition of mode setting value for ink cartridge exchange signal (input)

[Format]
~H(CNA,I
[Parameter] None
[Function]
This acquires the mode setting value for the ink cartridge exchange signal.
Return value after
executing this command
D/0
1
E/2
Mode in which the ink low signal (pin 8) is OFF (not output)
Mode in which the ink low signal (pin 8) is as follows: Normal: High, When there is little
ink remaining: Low
Mode in which the ink low signal (pin 8) is as follows: Normal: Low, When there is little
ink remaining: High
Mode in which the ink cartridge exchange signal (pin 22) is OFF (not output)
Mode in which the ink cartridge exchange signal (pin 22) is as follows: Normal: High,
When ink must be replaced: Low
Mode in which the ink cartridge exchange signal (pin 22) is as follows: Normal: Low,
When ink must be replaced: High