Connecting An Ethernet Cable To The Access Point (All Models) - Cisco 1552S Installation Manual

Hazardous locations
Table of Contents

Advertisement

Chapter 3
Installing the 1552 Series Access Points in Hazardous Locations

Connecting an Ethernet Cable to the Access Point (all models)

Please refer to the Declarations of Conformity and Regulatory Information when the
Note
AIR-CAP1552H-Q-K9 (POE input configuration only) will be installed in an explosive area in Japan.
The following tools and materials are required:
To connect the shielded Ethernet cable to the access point, follow these steps:
Disconnect power to the power injector, and ensure all power sources to the access point are turned off.
Step 1
This unit might have more than one power supply connection. All connections must be removed to
Warning
de-energize the unit. Statement 1028
Ensure a 6 AWG ground wire is connected to the access point (see the
Step 2
models)" section on page
Use an adjustable wrench, a 22-mm socket, or the Sealcon S-2200-WR wrench to remove the Ethernet
Step 3
connector plug from the access point (see
Figure 3-20
Shielded outdoor-rated Ethernet (CAT5e or better) cable with 0.2 to 0.35 in. (0.51 to 0.89 cm)
diameter
Note
The Ethernet cable from the power injector to the access point must be at least 10 ft
(3.05 m) long. The PoE Out port is disabled when the access point is powered by the power
injector.
RJ-45 connector and installation tool
Adjustable wrench
3-60).
Location of Ethernet Liquid-Tight Adapters (Only Models AIR-CAP1552SA/SD-x-K9,
AIR-CAP1552H-x-K9, and AIR-CAP1552WU-A-K9)
1
Figure 3-20
for the location).
4
5
2
Cisco Aironet 1552 Series for Hazardous Locations Installation Guide
Powering the Access Point
"Grounding the Access Point (all
6
3-73