Standards And Certifications - Cisco 6160 Installation And Replacement Notes

Replacement power entry module (pem)
Table of Contents

Advertisement

View PEM operating information.
Step 10
a.
b.
If a problem exists with the PEM operating information, refer to the Cisco 6160 Hardware Installation
Note
Guide for troubleshooting procedures.

Standards and Certifications

The Cisco 6160 PEM has the same standards and certifications as the Cisco 6160 chassis, as listed in
Table
Table 4
Discipline
Product Safety
Emissions
NEBS
Telecom
OL-2181-01
Type the following command:
DSLAM# show environment all
Scroll through the data and locate the PEM information.
If the PEM is operating properly, the information displayed on the screen will be similar to the
following output:
Slot 1
Power Modules:
Present:
Yes
Faults:
No
Internal Temp:
21C/69 F
External Temp 1:
20C/68 F
External Temp 2:
20C/68 F
Temp Alarms:
No
4.
Cisco 6160 Regulatory Compliance
Compliance Standard
UL 1950, 3rd Edition
EN 60950 2nd Edition, Amendments 1, 2, 3, 4, 11
IEC 2nd Edition, Amendments 1, 2, 3, 4
AS/NZS 3260
FCC Part 15
CISPR 22
ICCS-003
GR-63-CORE
GR-1089-CORE
SR-3580 Level 3
FCC Part 68
ICCS-003
Slot 2
Yes
No
22C/71 F
23C/73 F
20C/68 F
No
Standards and Certifications