Us er In stru ctio ns - Engli sh
Step 2
Secure snap hook (on shock absorber
lifeline end) and carabiner (on opposite
lifeline end) to O-rings on roof anchors.
Be sure snap hook and carabiner are
properly connected--closed and locked--
and no gate loading is present.
Step 3
Remove slack in system by
releasing the tension release
lever and pull the free end of the rope
through the tensioner.
Step 4
Tension the line with wrench or bar
rope while at the same time turning the
tensioner nut in the direction of the ar-
row. Tighten nut (1-3/16") until tensioner
begins to slip against the rope. Once
slippage occurs, DO NOT continue to
tighten the tensioner.
Step 5
Close the tension release lever to
prevent unintentional loosening of line
tension.
Use only connecting devices with compatible locking snap hooks,
auto-locking carabiners, or other Honeywell-approved connectors.