Read these instructions, the tool instructions and the warn-
ings and instructions for all equipment being used before op-
erating this tool to reduce the risk of electrical shock or
other serious personal injury.
• Use the RIDGID
®
RPA 120/220 AC Power (Mains) Adapter
only with the RIDGID
®
ifying the AC Power Adapter for other applications may damage
the equipment and/or cause personal injury.
• Do not probe AC Power Adapter terminals with conductive
objects. Shorting of terminals may cause sparks, burns or elec-
trical shock.
• Do not abuse the cord. Never use the cord for carrying,
pulling or unplugging the tool. Keep cord away from heat, oil,
sharp edges or moving parts. Damaged or entangled cords in-
crease the risk of electric shock.
• Always unplug the adapter from the outlet before removing
the adapter from the tool. This will reduce the risk or electrical
shock.
• Do not use in damp, wet or explosive environment. Do not ex-
pose to rain, snow or dirt. Contaminants and moisture increase
the risk of electrical shock.
• If operation in a damp location is unavoidable, use a ground
fault circuit interrupter (GFCI) protected supply. Use of a
GFCI reduces the risk of electrical shock.
• AC Power Adapter plug must match the outlet. Never mod-
ify the plug in any way. Unmodified plugs and matching outlets
will reduce risk of electric shock.
• Use an appropriate power source. Do not attempt to use a
step-up transformer, an engine generator or DC power re-
ceptacle. May cause damage to AC Power Adapter resulting in
electrical shock, fire or burns.
• Avoid body contact with earthed or grounded surfaces
such as pipes, radiators, ranges and refrigerators. There is
increased risk of electrical shock if your body is earthed or
grounded.
• Do not open the AC Power Adapter housing. Have repairs
performed only at authorized locations.
The EC Declaration of Conformity (890-011-320.10) will accom-
pany this manual as a separate booklet when required.
If you have any questions concerning this RIDGID
• Contact your local RIDGID distributor.
• Visit www.RIDGID.com to find your local RIDGID contact point.
• Contact RIDGID Technical Services Department at rtctechser-
vices.com, or in the U.S. and Canada call (800) 519-3456.
Description
The RIDGID RPA 120/220 AC Power Adapter is designed to be
used in place of the battery in the RIDGID RP 340 Press Tool to
allow the tool to be operated off an appropriate AC power source
(wall outlet).
Specification
Input ....................Available for 120V AC or 220V AC
Output ....................18V
Power Cord
Length....................16.4 ft (5m)
© RIDGID, Inc. 12/13
EC40379
WARNING
RP 340 Press Tool. Other uses or mod-
®
product:
Weight....................2.1 lbs (1.0 kg)
Dimension..............4.9" x 3.1" x 2.7"
(124 x 78 x 69 mm)
Temperature
Range ..................14°F to 140°F (-10°C to 60°C)
Cooling ................Passive convection cooling (no fan)
While the RIDGID RPA 120/220 AC Power Adapter will
NOTICE
physically fit onto and power other RIDGID 18V battery powered
equipment, use with equipment other than the RIDGID RP-340
Press Tool has not been evaluated to appropriate standards (ie.
UL/CSA/CE) and is not recommended.
Catalog
No.
Voltage
44823
120V
43338
220V
44468
120V
Icons
Double Insulated
Figure 1 – AC Power (Mains) Adapter Label
Inspection/Maintenance
Make sure the AC Power Adapter is unplugged. Clean the AC
Power Adapter with a soft cloth to aid inspection and control. In-
spect before each use for proper assembly, wear, damage or other
issues that could affect safe use. Make sure that the cord and plug
are not damaged. Confirm that the markings are present and read-
able. Do not use if any issues are found.
Set-
Up/Operation
Make sure all equipment is inspected and set up per its instruc-
tions.
1. Confirm that the AC Power Adapter is unplugged from any
power source and securely insert the AC Power Adapter into
tool battery port.
2. Run the cord along a clear path, and with dry hands plug the
AC Power Adapter into an appropriate power source. If the
power cord is not long enough, use an extension cord that:
• Is in good condition.
• Is appropriately rated for the use.
• Has sufficient wire size (16 AWG for 50' or less, 14 AWG for
50' to 100'). Undersized wires can overheat, melting the in-
sulation or causing fire or other damage.
Confirm the Red LED is ON and solidly illuminated. If the Red
LED is flashing;
• An excessive initial temperature or temperature increase
has occurred (Temperature Protection).
• A short circuit has occurred (Short Circuit Protection) or
overload protection.
• The Adapter is not working properly.
Unplug the AC Adapter from the power source and allow a
minimum of 5 minutes to cool down. The internal thermal over-
load will reset itself. If this does not solve issue, have adapter
serviced.
3. Operate the tool as per its instructions, following duty cycle.
4. Unplug AC Power Adapter with dry hands when not in use. Al-
RIDGID
®
Product Region
China AC Power Adapter
Europe AC Power (Mains) Adapter
North America AC Power Adapter
For Indoor Use Only
Plug
Type
A
C
A
999-999-465.10
REV. B

Advertisement

loading

Summary of Contents for RIDGID 44823

  • Page 1 The RIDGID RPA 120/220 AC Power Adapter is designed to be has occurred (Temperature Protection). used in place of the battery in the RIDGID RP 340 Press Tool to • A short circuit has occurred (Short Circuit Protection) or allow the tool to be operated off an appropriate AC power source overload protection.
  • Page 2 L'adaptateur de courant CA RPA 120/220 est conçu pour être util- men tation into national legislation, electrical equipment isé à la place de la batterie dans l'outil de presse RIDGID RP 340, that is no longer usable must be collected separately and disposed afin de permettre à...
  • Page 3 • Est en bon état. • Use el adaptador de electricidad de CA (red) RPA 120/220 • Est conforme aux normes pour cet usage. solamente con la selladora RP 340 de RIDGID ® . Otros usos o la modificación del adaptador de electricidad de CA para us- •...
  • Page 4 RIDGID puede físicamente conectarse y alimentar otros terna contra sobrecarga térmica se volverá a ajustar. Si esto equipos de RIDGID que usan baterías de 18 V, su uso con no resuelve el problema, pida que se le haga servicio al adap- equipos que no sean la selladora RP-340 de RIDGID no se ha tador.

This manual is also suitable for:

4333844468