Additional Instructions for Emergency versions
1. Ensure mains supply is turned OFF.
Connect mains supply cable to the 4-way plug supplied. (as shown opposite)
2. Knock out one of the 6.5mm dia knockout features in the geartray
cover with a gentle tap from a hammer, using a Philips screwdriver.
3. Refer to standard installation instructions 1 and 2.
Fit the LED into the mounting hole in the bezel using the
retaining clip provided. (Unless using Solstar attachment,
in which case see the Solstar attachments leaflet for LED position).
4. Refer to standard instructions 3 and 4.
Solstar with Digital Dimming
Please refer to 'Digital Regulating Luminaires' leaflet for further information.
Connect mains/controls cable to the 6-way plug supplied.
(as shown opposite) Note that both standard and emergency
luminaires have 6 pole mains/control connectors.
Safe Operation
1. Check the rating label for voltage and frequency before connecting this luminaire to the electrical supply.
2. Ensure that the mains supply is switched off when working on this luminaire, whether installing, re- lamping
or carrying out any other servicing.
3. Use the correct lamps as initially supplied or as indicated on the ballast label.
4. This luminaire is suitable for mounting in direct contact with non-combustible materials, e.g. Metal,
concrete, plaster. It is also suitable for mounting adjacent to normally flammable materials, e.g. Timber,
chipboard, providing the top surface is spaced not less than 25mm from such materials. Do not mount
luminaire on or close to readily flammable materials.
5. To prevent damage to H.F. Ballasts do not mix H.F. And conventional magnetic Ballasts on the same
electrical circuit.
6. Where use in more onerous situations is required, e.g. In part-completed buildings before "drying-out" is
completed, or areas where ambient temperatures are outside the normal temperature range, then consult
our Sales Office.
Servicing and Disposal
1. At commissioning and handing over of installation ensure that a copy of these instructions is presented to
the authority responsible for the operation and maintenance of the luminaries.
2. Servicing, e.g. cleaning, lamp replacement, must only be carried out after the electricity supply has been
switched off. It must not be assumed that luminaries with lamps not lit are switched off always check before
servicing.
3. Cleaning should be carried out at regular intervals to ensure that dirt does not accumulate to an extent that
will impair the thermal safety or optical performanceof the luminaire. Regular cleaning will also ensure that
the optical performance of the luminaries is maintained.
4. Failed lamps and starter switches must be replaced as soon as practicable by lamps and starters of the
same type. For electronic start circuits allow one minute for the thermal cut out to re-set before
switching on the mains supply.
5. At the end of life the lamp and luminaire are classed as WEEE under directive 2002/96/EC and should be
disposed of in accordance with local legislation.
Eaton
Wheatley Hall Road, Doncaster, South Yorkshire, DN2 4NB
Sales
T: +44 (0)1302 303303
F: +44 (0)1302 367155
E: sales@cooper-ls.com
Solstar (Horizontal)
Switched Live
1
Earth
N
Neutral
2
Unswitched Live
Switched Live
1
Earth
N
Neutral
2
Unswitched Live/Spare
D1
D1
D2
D2
General
International Sales
+44 (0)1302 321541
+44 (0)1302 303250
+44 (0)1302 303220
+44 (0)1302 303251
K1011V2
technical@cooper-ls.com
export@cooper-ls.com
Instruction Leaflet K1011V2
Solstar
(Horizontal)
with plug connector
Product luminaires comply with EN60598-1 and are suitable for use in normal interior conditions.
This luminaire has an ambient temperature range of 5 C to 25 C
Main casing
Note:
For attachments,
bezel fixings
may need fitting
prior to installation
April 2016
IP20
IP44
o
o
Gearbox
Fixing Clips
Reflector
Thumb wheel
Lamps
(Quantity dependent
on fitting)
IP65

Advertisement

loading

Summary of Contents for Eaton Solstar

  • Page 1 This luminaire has an ambient temperature range of 5 C to 25 C  Unswitched Live in which case see the Solstar attachments leaflet for LED position). 4. Refer to standard instructions 3 and 4. Solstar with Digital Dimming Switched Live Please refer to 'Digital Regulating Luminaires' leaflet for further information.