Models 8174 and 8175 (refer to Fig. 3 and 4)
1. Open the latch, and
2. Unscrew the locking thumbscrew to open the device.
3. Place the device on the appropriate lifeline with the arrow pointing upwards toward the lifeline
anchor point.
4. Close the device around the lifeline, tighten thumbscrew, and
5. Close the latch.
6. Connect device to full-body harness (see section 3.0, Making Connections).
7.
loaded cam handle that connects the gripping cams. Slide the rope grab to the desired position
on the lifeline and release the cam handle. The spring-loaded gripping cams will keep the rope
grab in position.
Fig. 3 - Model 8174
1
Fig. 4 - Model 8175
1
Us er In stru ctio ns - Engli sh
To reposition the rope grab on the lifeline, lift upward on the spring-