5 Port PoE Unmanaged 10/100Mbs Switch/Extender
(4 Ports Full PoE Power-up to 15.4 Watts per Port with 1 UPLINK Port up to 100Mbs)
This Guide provides information and procedures for the product installation and operation of the 5 Port PoE
Unmanaged 10/100Mbs Switch/Extender (LP-2334). This document is intended for technical personnel and
to use this document effectively, you should have a working knowledge of Local Area Networking (LAN)
concepts and hardware installation. In addition, you should be familiar with the following: Connection of
Patch Cables with RJ45 connectors and the LAN addressing map for your particular Network, Mounting of
Network hardware in a 19" equipment rack and local practices for power cord connections.
Read and keep these instructions. Follow all instructions and heed all warnings. Do not use this equipment
near water and clean only with a dry cloth. Do not block any equipment ventilation openings. Install in
accordance with manufacturer's instructions. Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including amplifiers) that produce heat. Unplug this equipment during
lightning storms or when unused for long periods of time. Refer all servicing to qualified service personnel.
Servicing is required when the equipment has been damaged in any way, liquid has been spilled, or object
has fallen into the equipment, the equipment has been exposed to rain or moisture, does not operate
normally, or has been dropped. The AC mains outlet, or appliance coupler shall be readily available to the
operator as a means of power disconnection.
CAUTION – These servicing instructions are for use by qualified service personnel only. To reduce the risk of
electric shock, do not perform any servicing other than that contained in the operating instructions unless
you are qualified to do so.
If You need Help or additional support relating to the contents of this Guide, please contact LAN Power
using one of the following methods: Phone: 1-510-275-4572 Fax: 1-510-824-5654 Mail: LAN Power, 47835
Westinghouse Drive, Fremont, CA 94539 Web Address: www.lan-power.com Email: support@lan-power.com
Before contacting LAN Power for technical support, please have the following information ready: the
product model number and unit serial number. A description of the failure or symptoms of problem. A
description of any action(s) already taken to resolve the problem (e.g., changing ports, rebooting the unit,
etc...). The type of End device being powered including Manufacturer name and part number. Powering
requirements of the End device. A description of your Network environment (layout, Ethernet switch
description, cable type, etc...). The unit history (i.e., have you returned the unit before, is this a recurring
problem, etc...)
Verifying Contents of Package - Unpack the PoE Injector and verify that you have the
following items: LP-2334 5 Port PoE Unmanaged 10/100Mbs Switch/Extender
NOTE: THE LP-2334 DOES NOT INCLUDE A POWER SUPPLY and MUST BE PURCHASED
SEPERATELY. Use either the LAN Power LP-2575 (Single Port ULTRA High Power Midspan
PoE Injector) or LP-2304PSU (AC Mains Power Supply Unit)
Technical Considerations
to a fixed location, consider all of the following: Determine optimal placement, check patch cord routing
and AC outlet location. Collect and document Network information as required. Ensure the CAT 5 (or
higher) cable length from the LP-2334 to the Powered End IP device does not exceed 328 feet/100 meters
total length.
Powering Up and Installing the 5 Port PoE Unmanaged 10/100Mbs Switch/Extender
1.)Connect the Power Supply Unit for the LP-2334 (which IS NOT SUPPLIED with unit and must be
purchased separately) The LP-2334 can be powered with one of the following units:
a.) Connecting a LAN Power LP-2575 (Single Port ULTRA High Power Midspan PoE Injector) – Connect
a LAN data cable - CAT 5 (or higher) from the RJ45 port labelled
the other end of the cable to the back of the LP-2334 into the RJ45 Port (far right RJ45) labelled
POWER INPUT (Min. 65 Watts) AND DATA OUTPUT (Max. 100Mbs)
IN
LED on the front of the LP-2334 will illuminate solid green.
LP-2334
Installation Guide
Purpose of this Guide
IMPORTANT SAFETY INSTRUCTIONS FROM LAN Power
Please note only qualified personnel should install this unit and
read instructions before attempting to install this unit
-
Before you mount the 5 Port PoE Unmanaged 10/100Mbs Switch/Extender
IEEE 802.3af
OUT
(bottom left) of the LP-2575 and
. Once connected the
Compliant
PoE
POWER

Advertisement

loading

Summary of Contents for LAN Power LP-2334

  • Page 1 LAN data cable - CAT 5 (or higher) from the RJ45 port labelled (bottom left) of the LP-2575 and the other end of the cable to the back of the LP-2334 into the RJ45 Port (far right RJ45) labelled POWER INPUT (Min. 65 Watts) AND DATA OUTPUT (Max. 100Mbs) POWER .
  • Page 2 LP-2334 will illuminate solid green. 2.)Attach a separate LAN data cable – CAT 5 (or higher) from the back of the LP-2334 for each of the 4 x RJ45 ports labelled POE POWER OUT (15.4 Watts per Port) 1 2 3 4 to each of the IP End Devices. Note: The maximum LAN data cable distance from LP-2334 to the IP End Device is 328 Feet/100 Meters.
  • Page 3 2 years from the original purchase date. Any warranty hereunder is extended only to the original consumer or purchaser and is not assignable. More at www.lan-power.com Notice to user LAN Power reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice.