X7 is the fiber-optic interface. Only driver COM2 can be configured into fiber-
optic mode.
X8 is the RS-485/IRIG-B interface. Both drivers COM1 and COM2 can be
configured to this interface: COM1 and COM2 can act as two RS-485 2-wire
links or, alternatively, COM1 can act as one single RS-485 4-wire link. Both ports
are galvanically isolated serial communication ports.
Table 22:
Connector X8 signals
Pin No
Pin name
1
GND
2
GNDC
3
NC
4
IRIG-B -
5
IRIG-B +
6
ISOL_GND
7
RS485 B1/-
8
RS485 A1/+
9
RS485 B2/-
10
RS485 A2/+
9
10
7
8
5
6
3
4
1
2
GUID-3638E235-AB2E-4571-B1EE-DF76AEA0FC36 V1 EN
Figure 14:
X8 connector pinout
Table 23: