B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 18 of 38)
ADDR
REGISTER NAME
6002
87L Signal Source
6003
87L Minimum Phase Current Sensitivity
6004
87L Tap Setting
6005
87L Phase Percent Restraint1
6006
87L Phase Percent Restraint2
B
6007
87L Phase Dual Slope Breakpoint
600C
87L Key DTT
600D
87L Diff Ext Key DTT
600E
87L Diff Target
600F
87L Differential Event
6010
87L Tap2 Setting
Open Pole Detect (Read/Write Grouped Setting)
6040
Open Pole Detect Function
6041
Open Pole Detect Block
6042
Open Pole Detect A Aux Co
6043
Open Pole Detect B Aux Co
6044
Open Pole Detect C Aux Co
6045
Open Pole Detect Current Source
6046
Open Pole Detect Current Pickup
6047
Open Pole Detect Voltage Source
6048
Open Pole Detect Voltage Input
6049
Open Pole Detect Pickup Delay
604A
Open Pole Detect Reset Delay
604B
Open Pole Detect Target
604C
Open Pole Detect Events
604D
Open Pole Detect Broken Co
CT Fail (Read/Write Setting)
6120
CT Fail Function
6121
CT Fail Block
6122
CT Fail Current Source 1
6123
CT Fail Current Pickup 1
6124
CT Fail Current Source 2
6125
CT Fail Current Pickup 2
6126
CT Fail Voltage Source
6127
CT Fail Voltage Pickup
6128
CT Fail Pickup Delay
6129
CT Fail Target
612A
CT Fail Events
Cont Monitor (Read/Write Setting)
6130
Cont Monitor Function
6131
Cont Monitor I OP
6132
Cont Monitor I Supervision
6133
Cont Monitor V OP
6134
Cont Monitor V Supervision
6135
Cont Monitor Target
6136
Cont Monitor Events
Autoreclose (Read/Write Setting) (6 modules)
6240
Autoreclose Function
6241
Autoreclose Initiate
6242
Autoreclose Block
6243
Autoreclose Max Number of Shots
6244
Autoreclose Manual Close
6245
Autoreclose Manual Reset from LO
6246
Autoreclose Reset Lockout if Breaker Closed
B-26
RANGE
0 to 5
0.2 to 4
0.2 to 5
1 to 50
1 to 70
0 to 20
0 to 1
0 to 65535
0 to 2
0 to 1
0.2 to 5
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 5
0.05 to 20
0 to 5
0 to 1
0 to 65.535
0 to 65.535
0 to 2
0 to 1
0 to 1
0 to 1
0 to 65535
0 to 5
0 to 2
0 to 5
0 to 2
0 to 5
0 to 2
0 to 65.535
0 to 2
0 to 1
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 1
0 to 1
0 to 65535
0 to 65535
1 to 4
0 to 65535
0 to 65535
0 to 1
L90 Line Differential Relay
APPENDIX B
UNITS
STEP
FORMAT
---
1
F167
pu
0.01
F001
---
0.01
F001
%
1
F001
%
1
F001
pu
0.1
F001
---
1
F102
---
1
F300
---
1
F109
---
1
F102
---
0.01
F001
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F167
pu
0.01
F001
---
1
F167
---
1
F102
s
0.001
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F102
---
1
F102
---
1
F300
---
1
F167
pu
0.1
F001
---
1
F167
pu
0.1
F001
---
1
F167
pu
0.1
F001
s
0.001
F001
---
1
F109
---
1
F102
---
1
F102
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
1
F102
---
1
F300
---
1
F300
---
1
F001
---
1
F300
---
1
F300
---
1
F108
GE Power Management
DEFAULT
0 (SRC 1)
20
100
30
50
10
1 (Enabled)
0
0 (Self-reset)
0 (Disabled)
100
0 (Disabled)
0
0
0
0
0 (SRC 1)
20
0 (SRC 1)
0 (Disabled)
60
100
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0 (Disabled)
0
0 (SRC 1)
2
1 (SRC 2)
2
0 (SRC 1)
2
1000
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
0
0
0
0 (Self-reset)
0 (Disabled)
0 (Disabled)
0
0
1
0
0
0 (Off)