Honeywell VM242A BasicMes-2 Operating Instructions Manual

Honeywell VM242A BasicMes-2 Operating Instructions Manual

Handheld flow measuring computer

Advertisement

Honeywell • All rights reserved
HANDHELD FLOW MEASURING COMPUTER
CONTENTS
1 Introduction ...................................................................... 2
1.1
How to use these Instructions ............................... 2
1.2
Safety Guidelines.................................................. 2
2 Basic Information ............................................................. 2
2.1
Intended Use......................................................... 2
2.2
Before Use ............................................................ 2
2.3
Scope of Delivery.................................................. 2
2.4
Names of the Components ................................... 3
2.5
Charging Batteries ................................................ 3
2.6
Replacing Batteries............................................... 3
2.7
Setup .................................................................... 3
3 Quick Start ....................................................................... 4
3.1
3.2
4 Function overview ............................................................ 5
4.1
How to access the Main Menu .............................. 5
4.2
4.3
4.4
4.5
Temperature Measurement................................... 7
4.6
Leakage Test ........................................................ 7
4.7
Data Logging......................................................... 7
4.8
DP Measurement .................................................. 7
4.9
USB Data Exchange ............................................. 8
4.10
Print ...................................................................... 8
4.11
Save Measurements ............................................. 8
4.12
Data management ................................................ 8
4.13
Setup .................................................................... 8
4.14
Calibration............................................................. 8
5 PC Software ..................................................................... 8
5.1
Overview............................................................... 8
5.2
System Requirements........................................... 9
5.3
Functions .............................................................. 9
6 Declaration of Conformity............................................... 10
8 Menu Structure............................................................... 12
9 Honeywell in EMEA and Asia Pacific ............................. 13
10 Data sheet...................................................................... 14
VM242A
OPERATING INSTRUCTIONS
MU2H-1054GE25 R0411

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell VM242A BasicMes-2

  • Page 1: Table Of Contents

    Functions .............. 9 6 Declaration of Conformity..........10 7 Illustrations / Abbildungen / figures / figura..... 11 8 Menu Structure............... 12 9 Honeywell in EMEA and Asia Pacific ......13 10 Data sheet..............14 Honeywell • All rights reserved MU2H-1054GE25 R0411...
  • Page 2: Introduction

    Scope of Delivery ESC key Safety Guidelines Item Spare part ordering number  Follow these operating instructions VM242A BasicMes-2 handheld flow VMS242A001 measuring device  Use the BasicMes-2  according to its intended use Four rechargeable AA size NiMH batteries ...
  • Page 3: Names Of The Components

    Change value of digit ↑↓ UP/DOWN NOTE Etc., when all changes are done:  Use dedicated battery charger supplied with device only Move cursor out of data field → Cursor disappears and new value is stored Honeywell • All rights reserved MU2H-1054GE25 R0411...
  • Page 4: Quick Start

    Valve Selection is updated every four seconds) or fast (measurement is updated every second) The BasicMes-2 has a database with valve data of Honeywell  Temperature unit: °C or °F balancing valves and common balancing valves of some  Display brightness: 20…100% (60%) other manufacturers.
  • Page 5: Function Overview

    When switched on the BasicMes-2 shows the main screen as measurement a default. How to access the main menu and a menu item: Operation Command Stop ongoing measurement Stop Operation Command Change to main menu Menu Increase presetting value ↑ Honeywell • All rights reserved MU2H-1054GE25 R0411...
  • Page 6: Project Function ("Select Project")

    B2 – If measurement has already been stored for this riser Only tagged data is printed when print function is used or which should not be overwritten: saved when save function is used. Decline to overwrite existing data MU2H-1054GE25 R0411 Honeywell • All rights reserved...
  • Page 7: Temperature Measurement

    The test consists of three parts: Zoom Zoom UP/DOWN  Switch on and/or set pump speed Zero calibration  Stabilisation period indicated by a countdown clock  Leakage test during which a graph is drawn Honeywell • All rights reserved MU2H-1054GE25 R0411...
  • Page 8: Usb Data Exchange

    Device returns to main menu  Download data from the BasicMes-2 after measurement  Print balancing report  Display and export results of leakage test and data logger  Show real time measurements of connected device MU2H-1054GE25 R0411 Honeywell • All rights reserved...
  • Page 9: System Requirements

     Design flow in l/h or m³/h  Selection of valve for this riser (see below) 5.3.5 Display realtime measurement  Remarks (free text field) Used to display measurements on a computer screen in real time Honeywell • All rights reserved MU2H-1054GE25 R0411...
  • Page 10: Declaration Of Conformity

    “New valve”  Fill fields “Manufacturer, Valve type, Diameter, Part number and Pre-settings with data The product: Honeywell VM242A BasicMes-2 handheld  Click “OK” to add the data to the database or “Cancel” to flow measuring computer...
  • Page 11: Illustrations / Abbildungen / Figures / Figura

    OPERATING INSTRUCTIONS VM242A BASICMES-2 ILLUSTRATIONS / ABBILDUNGEN / FIGURES / FIGURA Fig. 6. Fig. 1. Fig. 7. Fig. 8. Fig. 2. Fig. 3. Fig. 9. Fig. 4. Fig. 5. Fig. 10. Honeywell • All rights reserved MU2H-1054GE25 R0411...
  • Page 12: Menu Structure

    VM242A BASICMES-2 OPERATING INSTRUCTIONS MENU STRUCTURE MU2H-1054GE25 R0411 Honeywell • All rights reserved...
  • Page 13: Honeywell In Emea And Asia Pacific

    OPERATING INSTRUCTIONS VM242A BASICMES-2 HONEYWELL IN EMEA AND ASIA PACIFIC Honeywell • All rights reserved MU2H-1054GE25 R0411...
  • Page 14: Data Sheet

    VM242A BASICMES-2 OPERATING INSTRUCTIONS DATA SHEET MU2H-1054GE25 R0411 Honeywell • All rights reserved...
  • Page 15 -value of the orifice the flow is calculated using the k formula. The k value of all Honeywell balancing valves as well as some common valves of other manufacturers are stored in an internal database. Manual input of the k -value is also possible.
  • Page 16 • VM242A BasicMes-2 handheld measuring computer with Units and Display four rechargeable batteries and lanyard • Set of hoses with bypass assembly and Honeywell Pressure units mbar, bar, hPa, kPa, mH O, inH...
  • Page 17 VMS242A009 valve (for red hose) Adapters Rectus 21 socket onto 3/4” VMS242A004 internal thread, with sealing SafeCon socket onto VA2500B001 Rectus 21 plug Carry case Carry case with foam insert VMS242A007 for VM242A Honeywell Subject to change EN0H-2323GE25 R0111...
  • Page 18 Phone: +49 (6261) 810 Subject to change without notice Fax: +49 (6261) 81393 Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Z.A. La Pièce 16, www.honeywell.com 1180 Rolle, Switzerland or its Authorized Representative.

Table of Contents