10. PROGRAMMING THE LOCATIONS

L
0
P
OCATION
ROGRAMMING THE
Location 0 (zero) contains the module mode, i.e. system characteristics for operation on the
Internet.
.
If Location 0 / Segment 1 / Option 1 below is enabled (NX-590E is the primary
reporting device and the control panel is backup)
All event categories should be disabled in Location 4 of the control panel
(device 0). Failure to turn off these segments will cause events to be reported
by both the control panel and the NX-590E (dual reporting).
Test reports should be enabled (Loc 4 / Seg 1 / Opt 7 in control panel). Failure
to leave test reports enabled will result in the control panel NOT backing up
events that fail to communicate via the NX-590E. When properly set, test reports
will be reported by the control panel and the NX-590E.
Segment 1
1 = Use Control Dialer as Backup to TCP/IP and Email. Clear this option if the
2 = Enable if SIA; disable if Contact ID (factory default is 'off')
3 = Use Receiver #2 as Backup
4 = Send tag to on-site event recorder
5-8 = Reserved
Segment 2
1 = Enable site initiated downloading (r98 from a keypad).
2 = Allow remote downloading to the system over the Internet. You should
3 = Use DHCP (IP address is static if 0) (
4 – 7 = Reserved
8 = Enable AA polling (poll every period of less than 5 minutes)
Segments 3-8 Reserved
L
1
P
OCATION
ROGRAMMING
F
SEGMENTS OF
EATURE
Location 1 contains the partition(s) that should be included when reporting over the Network. If
you wish to exclude any partition from reporting, simply turn off the LED corresponding to that
particular partition. If the partition LED is off, no event from that partition will report via network
regardless of what is programmed elsewhere. Using Table 10-1 enter the corresponding
number of the partition(s) to include for each type of report found in Segments 1 –16. Factory
default is all partitions on.
Table 10-1
1 = Partition 1
2 = Partition 2
NX-590E Internet Interface
M
ODE
control panel is primary/dual report. (Refer to note in box above.)
program this to 0 unless you absolutely have to program the system over
the network.
Private networks behind a firewall may want to take
advantage of this feature.
we strongly recommend that Polling in option 8 also be enabled.)
P
ARTITIONS
S
D
ELECTION
ATA
3 = Partition 3
4 = Partition 4
(8
SEGMENTS
T
R
O
EPORT VIA
)
5 = Partition 5
6 = Partition 6
F
S
EATURE
ELECTION DATA
If this DHCP option is enabled,
I
R
NTERNET TO
ECEIVER
7 = Partition 7
8 = Partition 8
)
#1 (16