Serial Outputs - Bosch PSI 6XXX.350 L1 Series Technical Information

Timer and i/o level
Table of Contents

Advertisement

7.3.2

Serial outputs

Example of outputs
1070 080 067-101 (2001.03) GB
PSI 6XXX.350 L1
The outputs are driven via the serial INTERBUS-S interface. The setup is as follows:
Bit
Outputs of the PSI 6XXX.350 L1 according to the enhanced C0 profile by
Bosch
0
<Weld complete>
1
<Tipdress request> (tip dress inquiry)
2
<Prewarning>
3
<End of Stepper> reached
4
<Control ready>
5
<Welding fault>
6
<Without weld process monitoring> or without stepper values
7
<Weld/No weld> (with welding current)
8
<Proportional control valve selection_1>
9
<Proportional control valve selection_2>
10 <Proportional control valve selection_4>
11
<Proportional control valve selection_8>
12 <Proportional control valve selection_16>
13 <Proportional control valve selection_32>
14 <Proportional control valve selection_64>
15 <Proportional control valve selection_128>
16 <Initial (Start) Tipdress request>
17 <Current scaling/check finished>
18 <Pressure calibration/check finished>
19 -
-
27 -
-
47 -
Word
Low byte
0
O07 ... O00
1
O23 ... O16
2
O39 ... O32
Electrical connection
High byte
O15 ... O08
O31 ... O24
O47 ... O40
7-37