2.
Connection Configuration
SAN Connection
Access Method
This section explains the connection configurations between server Host Bus Adapters (HBAs) and ETERNUS DX
host interface ports.
■
Single Path Connection
A single path configuration connects the ETERNUS DX to a server via a single path.
The server cannot access an ETERNUS DX when a component (such as a controller, HBA, switch, or cable) on the
path has a problem. The system must be stopped when a failed component on a path needs to be replaced or
when the controller firmware needs to be updated.
In a single path connection configuration, the path failover and load balancing functions are not supported.
A multipath connection configuration is recommended to maintain availability when a problem occurs.
Figure 60 Single Path Connection (When a SAN Connection Is Used — Direct Connection)
Server
HBA
Port
Port
CA
CM#0
Figure 61 Single Path Connection (When a SAN Connection Is Used — Switch Connection)
Server
HBA
Port
Port
CA
CM#0
FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Design Guide (Basic)
Server
HBA
Port
Port
CA
CM#1
ETERNUS DX
Server
Server
HBA
HBA
Switch
Port
Port
CA
CM#1
ETERNUS DX
Copyright 2019 FUJITSU LIMITED
105