Page 3
This manual describes operation management and maintenance for the FUJITSU Storage ETERNUS DX60 S2 Disk storage system. This manual is intended for use of FUJITSU Storage ETERNUS DX60 S2 Disk storage system in regions other than Japan. Please carefully review the information outlined in this manual.
This chapter describes the components of the FUJITSU Storage ETERNUS DX60 S2 Disk storage system. ● Chapter 2 Standard Operations This chapter explains how to turn on and off the FUJITSU Storage ETERNUS DX60 S2 Disk storage system and how to operate the buttons on the operation panel. ● Chapter 3 Setup This chapter describes the required settings and notes for operation of the FUJITSU Storage ETERNUS DX60 S2 Disk storage system.
Page 5
WARNING properly. This symbol indicates the possibility of minor or moderate personal injury, as well as damage to the FUJITSU Storage ETERNUS DX60 S2 and/or to CAUTION other users and their property, if the FUJITSU Storage ETERNUS DX60 S2 Disk storage system is not used properly.
FUJITSU Storage ETERNUS DX60 S2 Disk storage system. Abbreviations Used in This Manual • "ETERNUS DX Disk storage system" or "ETERNUS DX60 S2" refers to the FUJITSU Storage ETERNUS DX60 S2 Disk storage system. • "Host Bus Adapter (HBA)" refers to the interface module that is normally used by the server to connect to ETERNUS DX Disk storage systems.
Page 8
Maintenance Support Period ..................... 80 6.5.2 Related Service ......................... 80 Chapter 7 Troubleshooting ..............81 Check List ......................81 Required Information for Inquiries ..............86 FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 9
Informational Messages ......................109 A.2.5 Test Messages ........................118 A.2.6 Sense Codes ........................... 118 Appendix B Event (SNMP Trap) Display When Using ServerView Operations Manager ........121 FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 10
ETERNUS Web GUI screen...................... 52 Figure 4.4 Event notification ........................54 Figure 5.1 Position of 2.5" disk slots......................56 Figure 5.2 Position of 3.5" disk slots......................56 FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 11
Table 6.1 Time for volume formatting (disk) ....................78 Table 6.2 Rebuild process time (disk) ....................... 79 Table 6.3 Copyback process time (disk) ....................79 FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Front view of a 3.5" type controller enclosure (with front cover) ● Without front cover 3.5-inch disk Operation panel Figure 1.3 Front view of a 3.5" type controller enclosure (without front cover) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
■ Operation panel An operation panel has LEDs, a power switch, an AUTO POWER switch, a MODE SELECT switch, and an IP RESET switch. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Enables the device power to be turned on via power linkage. The MODE SELECT switch is enabled for the factory default setting. Do not change to OFF. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED...
DISK FAULT LED Figure 1.8 2.5" type disk Figure 1.9 shows the slot number of each disk. Figure 1.9 Disk slot numbers (2.5" type controller enclosure) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
• System disks are installed in Slot#0 and Slot#1. Never remove system disks. Doing so will render the ETERNUS DX Disk storage system unusable. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
FC port (0 (Left), 1 (Right)) UNIT READY/FAULT LED MASTER LED PWC port ACT LED LINK LED DI (OUT) port Figure 1.12 Controller (FC model) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 18
The controller is sending or receiving data via the LAN port (for operation management). (green) LINK The link between the LAN port (for operation management) and the destination has been (green) established. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
(blinks blue) (off) DI (OUT) LINKUP The link between the DI (OUT) port and the destination has been established. (green) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
A single controller has one LAN (RMT) port and one LAN (MNT) port. • SAS port (0 (left), 1 (right)) These are the miniSAS (SFF8088) connectors to connect miniSAS cables. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 21
If a power outage is detected, data in the cache memory is saved to a non-volatile memory in the controller using the SCU. The saved data is retained in the non- volatile memory indefinitely. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
ETERNUS DX Disk storage system (DC power) is not (blinks green) turned on. The power supply unit or the fan in the power supply (orange) unit is in error status. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Single expander type Expander (EXP#0) Cover Power Supply Unit Power Supply Unit (PSU#0) (PSU#1) Figure 1.18 Rear view of drive enclosure (single expander model) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
The MODE SELECT switch is enabled for the factory default setting. Do not change to OFF. • LEDs The states of LEDs are listed below. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
LED name LED status Disk status DISK READY/ The disk is operating normally. FAULT (green) (blinks green) The disk is in error status. (orange) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
FAULT (green) • The controller is performing the initial setup after the (orange) power is turned on. • The expander is in error status. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
ETERNUS DX Disk storage system (DC power) is not (blinks green) turned on. The power supply unit or the fan in the power supply (orange) unit is in error status. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
• Outlet (OUTPUT) This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
• Outlet (OUTPUT) This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC output cable). FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
For 1U power distribution unit Main line switch Figure 2.1 ON position (marked "|") of the main line switches on a 1U power distribution unit FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
For 1U power distribution unit Main line switch Figure 2.3 OFF position (marked "O") of the main line switches on a 1U power distribution unit FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
"ON". Do not turn the main line switches of the power distribution units to the OFF position. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 33
When drive enclosures are installed, the power turns on automatically. Power switch Drive Enclosure Controller Enclosure After three minutes, check that the READY LED on the controller enclosure are lit up. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
This section explains how to use the Power switch to turn off the ETERNUS DX Disk storage system. For other procedures, refer to the related manuals. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED...
This section explains how to attach and remove the flange cover of the 2.5" type controller enclosure. CAUTION • At the completion of this operation, check that the flange cover is attached. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 36
Tighten the thumb screw to fasten the flange cover. Thumb screw End of procedure ■ Procedure for removing the flange cover Loosen the thumb screw to remove the flange cover. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Be careful so that the part of the front cover to be fit in the slot does IMPORTANT not touch the power switch ( Slot FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 38
When attaching the right side of the front cover, support its left side with your left hand, to prevent it from coming loose and falling. End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
When the AUTO POWER switch of the controller enclosure is set to "OFF", the AC automatic linkage mode is disabled. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 40
35). For details on how to attach the front cover, refer to "2.3 Attaching and Removing the Front Cover" (page 37). End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
To restore the LAN port settings (network environment settings) to the factory default Press the IP RESET Switch twice within two seconds. IP RESET switch FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 42
35). For details on how to attach the front cover, refer to "2.3 Attaching and Removing the Front Cover" (page 37). End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
• Snap Data Pool Volumes (SDPVs) cannot be encrypted after they are created. To create an encrypted SDPV, set encryption when creating a volume. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
If a disk is activated from the stopped state more than a set amount of times in a day, the Eco-mode schedule is not applied and disk motors are not stopped by the Eco-mode. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED...
Page 45
To prevent this from occurring, the RAID configuration and disk installation must be taken into consideration. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
The RAID level may also be changed when adding new disks to a RAID group. This is used to convert the RAID level of all the volumes belonging to a given RAID group. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED...
For details on the LDE procedure, refer to "ETERNUS Web GUI User's Guide" or "ETERNUS CLI User's Guide". • A RAID group can be specified as a target for LDE. • Multiple LDEs cannot be performed simultaneously. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
However, RAID groups with the same RAID level and same disk type are recommended for concatenated volumes to ensure that performance is not affected. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 49
When a volume that is using ETERNUS SF AdvancedCopy Manager to run backups is expanded via LUN Concatenation, the volume will need to be registered with ETERNUS SF AdvancedCopy Manager again. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
IP addresses of the previous Master CM’s are taken over by the new Master CM. Figure 4.1 LAN control (switching of the Master CM) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Event notification and status display for the ETERNUS DX Disk storage system can be performed by ETERNUS CLI. When ETERNUS CLI is used, refer to "ETERNUS CLI User's Guide". FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Status of each component in the ETERNUS DX Disk storage system is monitored periodically, and the result is displayed as a general status image with character strings. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED...
When an event occurs in the ETERNUS DX Disk storage system, host senses (sense codes) are sent to the server. For details on sense codes, refer to "Appendix A Event Notification Message List" (page 88). FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
ETERNUS DX Disk REMCS/SNMP (*1) Host sense storage system *1: SNMP for the EMEA&I region and REMCS for all other regions Figure 4.4 Event notification FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Do not uninstall or move a disk that is already installed. Contact your sales representative or maintenance engineer if disks that are installed by default need to be uninstalled or moved to another slot. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Failure to discharge static electricity may cause device failure. • Leave the disk in its package until ready to install it. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Storage System Status screen of ETERNUS Web GUI. Wear a wrist strap or touch a metal part to discharge the human body's natural static electricity. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 59
Insert the disk all the way into in the slot, making sure that it is firmly seated and keeping the lock lever open. Hold the disk with both hands to protect against jarring. IMPORTANT FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 60
"2.3 Attaching and Removing the Front Cover" (page 37). Wear a wrist strap or touch a metal part to discharge the human body's natural static electricity. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 61
Hold the disk with both hands to protect against jarring. IMPORTANT • Insert the disk until the lock lever hooks reach the slot protrusions. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 62
Set up RAID groups, volumes, hot spares, and Host Affinity settings on the new disks, as required. End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
When handling drive enclosures, make sure to wear a wrist strap or touch a metal part to discharge the human body's natural static electricity. Failure to discharge static electricity may cause device failure. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Install the disk after expanding the drive enclosure. Procedure Wear a wrist strap or touch a metal part to discharge the human body's natural static electricity. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 65
M5 Centering screw (10mm) M5 Cage nut M5 Pan head screw (10mm) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 66
(for left side). (Front rack pillars) Rack rail (for right side) "R" is stamped on the inner side of the rack rail [Right] (for right side). FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 67
Failure to do so may cause injury. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 68
Check that the MODE SELECT switch is set to the ON position. Do not change to OFF. AUTO POWER switch MODE SELECT switch End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Click [Add Drive Enclosure] under the [Hardware Maintenance] menu on the [Maintenance] tab in the ETERNUS Web GUI screen. The [Add Drive Enclosure] initial screen appears. Click the [Next>] button. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 70
(1) Connect the plug to be connected to DI (OUT) port, to the DI (OUT) port of the Controller 0 (CM#0). Remove the port cover from the DI (OUT) port before inserting the plug. Controller enclosure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 71
Do not connect anything to the DI (OUT) port on the drive enclosure. IMPORTANT For a single-controller type EXP#0 Drive enclosure CM#0 Controller enclosure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 72
The power cords must be connected to the inlets of both power supply units. Connect the power cord plugs to the inlets of the power supply units. PSU#0 PSU#1 Inlets Power cord plug FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 73
Click the [Next>] button. The drive enclosure recognition process is performed. When the process completes, the drive enclosure's AUTO POWER switch check procedure screen is displayed. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 74
Attach the front cover. For details on how to attach the front cover, refer to "2.3 Attaching and Removing the Front Cover" (page 37). End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
If management software such as ETERNUS SF Storage Cruiser is installed, refer to the manuals that are supplied with the management software and check the required settings. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED...
FC card in the ETERNUS DX Disk storage system. When the setting is complete, confirm that the server can access the ETERNUS DX Disk storage system. End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
SAS card in the ETERNUS DX Disk storage system. When the setting is complete, confirm that the server can access the ETERNUS DX Disk storage system. End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
The value shows the time required for volume formatting when the volume capacity is 100GB and there is no server I/O. The time that is required depends on the type and configuration of the disk. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED...
The time required to copyback a 100GB volume of the indicated RAID level, number and type of disks when there is no concurrent server I/O. The time that is required depends on the type and configuration of the disk. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
If a possible error that may occur is detected or an error occurs when remote support is used, the contents of events are automatically sent to the remote support center and then the user is notified by the remote support center. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
If the ETERNUS DX Disk storage system is in AC automatic power mode (i.e. AUTO POWER switch is turned to ON), the ETERNUS DX Disk storage system turns on automatically after the power is restored. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 82
Connect the miniSAS cable while the drive enclosure is on. Press the controller enclosure's Power Switch to turn on the ETERNUS DX Disk storage system. End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 83
Note that the settings (network environment settings) for all of the LAN IMPORTANT ports are initialized after the following procedure is performed. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 84
Check that the ETERNUS DX Disk storage system can be connected to via each of the desired network services. If not, contact your maintenance engineer. End of procedure FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 85
Check if an error occurs in a path by using a path management tool such as ETERNUS Multipath Manager. Refer to the relevant manuals and take the required actions. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED...
CLI> show enclosure-status Enclosure View Name [ETERNUS DX60 S2] Model Upgrade Status [Not Possible] Model name Model Name [ETxxxxx] Serial Number [xxxxxxxxxx] Serial number FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 87
Disk storage system, obtain the required log/dump information using the log/dump collection function of ETERNUS Web GUI. Refer to "ETERNUS Web GUI User's Guide" for how to obtain this information. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
14:Volume10 Open 512MB 2:RAIDgrp 15:Volume11 Open 512MB 2:RAIDgrp 16:Volume12 Open 512MB 2:RAIDgrp 17:Volume13 Open 512MB 2:RAIDgrp 18:Volume14 Open 512MB 2:RAIDgrp 19:Volume15 Open 512MB 2:RAIDgrp FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 89
The year is display with four digits. The detailed information of the event is displayed. For multiple process results, each process result is displayed on a separate line. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Trap No. 5 returns to normal status. fjdarye101SensorStatusChangeToNormal This Trap is sent to notify that an event notified by Trap No. 6 returns to normal status. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 91
The operation time of the 1.3.6.1.2.1.11.1 SNMP Agent (centiseconds) The operation time is reset authenticationFailure 1.3.6.1.2.1.11.5 when the SNMP Agent starts or restarts. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 92
Information[2]:fjdarySspMachineId ToNormal Trap No. 5 Information[3]:fjdaryTrapMessage Information[4]:fjdaryTrapWarningInfo 26 fjdarye101 Notification of Information[1]:fjdaryTrapItemId SensorStatus alarm cancel for Information[2]:fjdarySspMachineId ChangeTo Trap No. 6 Information[3]:fjdaryTrapSensorInfo Normal Information[4]:fjdaryTrapMessage FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 93
26 fjdarye101 Notification of 1.3.6.1.4.1.21 Information [3]:fjdaryTrapItemId SensorStatus alarm cancel for 1.4.1.1.126.1. Information [4]:fjdarySspMachineId ChangeTo TRAP No. 6 101.0.26 Information [5]:fjdaryTrapSensorInfo Normal Information [6]:fjdaryTrapMessage FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
ETERNUS Web GUI or ETERNUS CLI. For details on the sense code that is notified to the server, refer to "A.2.6 Sense Codes" (page 118). FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
CM and DE. Power Supply Unit Power supply units for units in CEs or DEs. Abbreviation Meaning SMART Self-Monitoring Analysis and Reporting Technology Firmware FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
CM number (0 – 1) zz: Model name (FC4G, SAS, or iSCSI) xx: CPU frequency (1.2GHz) pp...: Component number ss...: Serial number rr...: Version FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 97
CM number (0 – 1) zz: Model name (FC4G, SAS, or iSCSI) xx: CPU frequency (1.2GHz) pp...: Component number ss...: Serial number rr...: Version FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 98
CM number (0 – 1) zz: Model name (FC4G, SAS, or iSCSI) xx: CPU frequency (1.2GHz) pp...: Component number ss...: Serial number rr...: Version FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 99
Disk capacity (GB/TB) operations. yy: Disk speed cc...: Disk information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 100
Disk capacity (GB/TB) yy: Disk speed cc...: Disk information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 101
PSU slot number (0 – 1) notification setting. pp...: Component number They are not notified ss...: Serial number during maintenance rr...: Version operations. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 102
The copy sessions are in normal status. M 13CE0006 13CE0006 Halt session was cleared. Halt status in the copy session was removed. The copy sessions are in normal status. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 103
M E2070011 E2070011 NOT READY(17:CM Memory Shortage) The device is in Not Ready status. Memory capacities are smaller than the minimum value in multiple CMs. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
CM number (0 – 1) zz: Model name (FC4G, SAS, or iSCSI) xx: CPU frequency (1.2GHz) pp...: Component number ss...: Serial number rr...: Version FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 105
CM number (0 – 1) zz: Model name (FC4G, SAS, or iSCSI) xx: CPU frequency (1.2GHz) pp...: Component number ss...: Serial number rr...: Version FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 106
Disk capacity (GB/TB) yy: Disk speed cc...: Disk information (RAID level or hot spare (Spare)) pp...: Component number ss...: Serial number rr...: Version FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 107
CM number (0 – 1) zz: Model name (FC4G, SAS, or iSCSI) xx: CPU frequency (1.2GHz) pp...: Component number ss...: Serial number rr...: Version FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 108
SS: Component subtype dd: DE-ID ("00" for a controller enclosure) This row indicates TrapWarningInfo for Trap No. 5 and TrapSensorInfo for Trap No. 6. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Snap Data Pool (encrypted) usage rate exceeds the threshold (Level1) $a% and reaches $b%. $a: Usage rate of Snap Data Pool $b: Threshold of Snap Data Pool FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 110
Informational $a:$b Level in the event notification setting. %d RAID groups are deleted. %d: Quantity $a: RAID group number $b: RAID group name FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 111
%d volumes are created. %d: Quantity $a: Volume number $b: Volume name $c: Volume type $d: Capacity (MB) $e: RAID group number FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 112
%b: Port number (0 – 1) setting. $a: Host affinity (Enable or Disable) $b: Reset Scope (I_T_L or T_L) $c: Reserve Reservation if Chip Reset (Enable or Disable) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 113
A SAS host is registered. setting. $a: Host number $b: Host name $c: SAS address $d: Host response number $e: Host response name FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 114
Level in the event notification setting. %d host names are changed. %d: Quantity $a: Host number $b: Host name (before change) $c: Host name (after change) FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 115
A LUN mapping (with host affinity disabled) is registered. %a: CM number (0 – 1) %b: Device number (0 – 1) $c: Logical unit number $d: Volume number $e: Volume name FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 116
%a: CM number (0 – 1) %b: Port number (0 – 1) $a: Host number $b: Host name $c: Host affinity group number $d: Host affinity group name FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 117
DE intake temperature error. dd: DE-ID ("00" for a controller enclosure) This row indicates TrapWarningInfo for Trap No. 25 and TrapSensorInfo for Trap No. 26. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Disk is disconnected because an error occurred during These sense codes are notified when the Write check of the disk patrol. the relevant event is detected during Disk Patrol. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
CM SAS Port error is detected. maintenance operations. CM BE Expander Port error is detected. CM Flash ROM error is detected. CM NAND Flash error is detected. FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
They are not notified during PSU error is detected. maintenance operations. DE exhaust temperature error (Warning) is detected. DE intake temperature error (Warning) is detected. CM is rebooted FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
INFORMATIONAL Item fault to normal, from %s, id: %x, message: %s 22 An event notified by normal (*2) "Item fault" returns %s: fjdarySspMachineId to normal status %x: fjdaryTrapItemId %s: fjdaryTrapMessage FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 122
%x: fjdaryTrapSensorInfo %s: fjdaryTrapMessage For variable-bindings values, refer to "variable-bindings meanings" (page 94) "A.1.3 Host Sense" (page 94). The default setting is "Disable" (no notification). FUJITSU Storage ETERNUS DX60 S2 Disk storage system User’s Guide -Operation- Copyright 2014 FUJITSU LIMITED P3AM-5512-07ENZ0...
Page 123
However, Fujitsu shall assume no responsibility for any operational problems as the result of errors, omissions, or the use of information in this manual. • Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual. •...