Supply Output; Set - Honeywell Accenta Series Engineer's Manual

Table of Contents

Advertisement

Bell Box (cont'd)
Panel
Board
J6
+
TROBE
Board
Reson8
13V Supply Output
The 13V output is to power detectors which require a voltage supply (PIR detectors etc). The supply is
present at all times and may be used to supply a total load of 350mA.

Set

The output marked SET is used with latching detectors. The output becomes positive on correct Set of the
system and is removed by entry of a valid user code.
ET
D
B
T
A
BELL
CB
+
+
+
HOLD
BATTERY
RTN
TRIG
OFF
T
D
A
B
Figure 12. Twin External Bell-box Wiring
Accenta/Optima Engineer's Manual
F3
1A
TB
Board
Reson8
10
+
+
HOLD
BATTERY
RTN
TRIG
OFF
T
D
A
B
TB