Panasonic LP-400 Series External Control Manual page 131

Laser marker
Hide thumbs Also See for LP-400 Series:
Table of Contents

Advertisement

⿎ CO
laser frequency : MPL
2
[Supported models: LP-400 series]
Sets the laser frequency of LP-400 series.
• Setting / Readout data of laser frequency
Sub
STX
MPL
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
• Readout request of laser frequency
STX
MPL
R
Data
Name
length
[byte]
Laser frequency
⿎ Line width/marking pitch : WDC
Sets the width necessary to avoid crossing at marking intersection and marking pitch of the bold characters and bar code.
• Setting / Readout data of line width and marking pitch
Sub
STX
WDC
command
Sub command is "S" at the time of setting and "A" for response data at the time of readout.
• Readout request of line width and marking pitch
STX
WDC
R
Data
Name
length
[byte]
Line width
Marking pitch
[Laser frequency]
1-byte
(Check sum)
Delimiter
Description
"0": 5 kHz
1
"1": 10 kHz
"2": 20 kHz
[Line width] [Marking pitch]
10-byte
(Check sum)
Delimiter
Description
5
"0.010"–"2.000" [mm]
5
"0.010"–"2.000" [mm]
(Check
Delimiter
sum)
(Check
sum)
The line width for crossing avoidance at the crossing
point of marking line is indicated.
Sets the marking pitch of the bold characters and bar
code module.
ME-LP400V-EX-6
Remarks
Delimiter
Remarks
131