Calibrating the Bias Current and Recording
Level
Although the ATS (Automatic Tape Selection) system in
your unit sets the appropriate equalization characteristics
and bias current for each tape type, you may be able to
obtain even better results by doing the bias current and
recording level calibration function described below.
BIAS
+
Adjusts the bias
current within a
range of about 20 %
Bias calibration
Choosing the proper bias current for a tape ensures
minimum distortion and flat frequency response. Lowering
the bias current boosts high-frequency response, but also
results in higher distortion. Raising the bias, on the other
hand, reduces distortion, but also dampens high-frequency
response. You thus obtain proper bias when the bias current
and high-frequency response are well balanced.
BIAS
Bias
Bias
reduced
increased
(high-
(high-
+
frequency
frequency
response
response
boosted)
suppressed)
•By changing the bias, you can tailor the response to your
liking, for example by slightly emphasizing the upper or
lower end.
•The frequency response of metal tape is much less affected
by changes in the bias current than other tape types, and in
some cases is uneffected. The adjustment range of this deck
(about 20 %) may therefore not be wide enough to allow
adjustment for all tapes.
Recording level calibration
Even when the recording level is adjusted correctly, a tape
with low sensitivity will result in a low playback level. The
REC LEVEL calibration control allows you to compensate for
sensitivity differences among tapes to equalize both
recording and playback levels. This is especially important
when using the Dolby NR system, since the system is most
effective when recording and playback levels are the same.
14
REC LEVEL
+
CALIBRATION
Adjusts the recording
level within a range
of about 3 dB
Bias reduced ( )
Bias increased (+)
Frequency in Hz
Follow the procedure below to calibrate the bias current and
recording level.
POWER
ON
COUNTER
RESET
MEMORY
POWER
PAUSE
REC MUTE
REC
·
p
0
)
P
R
r
0 AMS )
3
1
Insert a cassette with the side to be
recorded facing outward.
EJECT
§
POWER
p
0
2
Press CALIBRATION.
CALIBRATION
The peak level meters for adjusting the bias and
recording level appear in the display window.
3
Press r , then P or · to turn on the
recording test tones.
REC
PAUSE
P
Playback level for an 8-kHz signal
H
L
REC CAL
Playback level for a 400-Hz signal
Notes
•You cannot monitor the sound during the
calibration operation.
•It takes 2 to 3 seconds for the test tone level to
stabilize.
4
5
REC LEVEL
MPX FILTER
5
Ø
ON
ø
OFF
4
6
3
7
DOLBY NR
BIAS
REC LEVEL
OFF
2
8
B
BALANCE
C
S
1
9
0
+
+
10
L
R
EJECT
MONITOR
CALIBRATION
HEADPHONES
§
1
2
MPX FILTER
Ø
ON
ø
OFF
DOLBY NR
BIAS
OFF
B
C
COUNTER
S
RESET
MEMORY
EJECT
MONITOR
PAUSE
REC MUTE
REC
·
§
)
P
R
r
0 AMS )
r
·
or
TYPE
REC LEVEL
2
+
+
CALIBRATION

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents