WE ADVISE THE USE OF THIS EQUIPMENT ONLY BY PROFESSIONAL OPERATORS. ONLY USE THIS MACHINE FOR USAGE SPECIFICALLY MENTIONED IN THIS MANUAL. Thank you for choosing a LARIUS S.R.L. product. As well as the product purchased, you will receive a range of support services enabling you to achieve the results desired, quickly and professionally.
PEGASO WORKING PRINCIPLE The PEGASO apparatus is an electric pump, used for On the end of the feed pipe there is a maximum pressure valve, in order to eliminate choking or occlusions that can spraying wall plaster or synthetic materials for covering damage the pipe.
The packed parts should be handled as indicated has been any damage due to transportation. in the symbols and markings on the outside of the In case of damage, call immediately LARIUS and the packing. Shipping Agent. All the notices about possible damage or anomalies must arrive timely within 8 days at least •...
Page 9
PEGASO • NEVER USE THE TOOLING IN PRESENCE OF POTEN- • BEFORE USING THE TOOL, ENSURE THERE ARE NOT TIALLY EXPLOSIVE GAS. DAMAGED PARTS AND THE MACHINE CAN WORK PRO- PERLY. Always check the product is compatible with the materials •...
PEGASO SETTING-UP CONNECTION OF THE FLExIBLE HOSE TO THE GUN • Connect the pressure flexible hose to the pump and the gun tightening the metal clamps. NEVER use sealants on fittings threads. The type of materiel you are spraying will determine the maximum lenght of hoseyou can use.
PEGASO SETUP • Connect one end of air hose to sprayer air outlet quick connect and to gun air inlet quick connect (G1). • Connect one end of material hose to material outlet and the other end to gun material inlet (G2). Firmly tighten the metal clamps.
PEGASO POSITION AND INSTALLATION OF THE TANK • The 50 litre tank can be disassembled and easily cleaned. • Unscrew the bolts and insert/disengage the basket supporting the tank from the machine body, or lift the tank to remove it from its support.
PEGASO CONTROLS Display, pump pressure reading LED. Sprayer starter switch - In the “0” position the machine is not powered - In the “1” position the machine is powered Power supply socket (220 V) for attaching supple- mentary apparatus (such as a drill).
PEGASO STARTUP STARTING THE SYSTEM MAIN METHOD WITH AIR FLOW • Turn sprayer main power ON. • Start the pump. • Turn the “Pump Rotation” selector clockwise. • Start the compressor. • Close the recycle valve (L3). • Open the air valve (L1) on the regulator and on the gun (L2).
PEGASO WASHING OF THE NEW EQUIPMENT • The equipment has already been adjusted at our factory with light mineral oil left inside the pumping group as protection. Therefore, wash with diluent before sucking the product. • Pour 4 litres of clean water into hopper (1).
PEGASO STARTING THE SPRAYING OPERATIONS Use the tooling after performing all the SETTING UP operations above described. • • Fill the tank with suitably prepared material. • Install the nozzle depending on the material you wish to use. See the nozzle selection table.
Page 17
PEGASO REGOLATIONS FLOW ADJUSTMENT • The flow of material must be adjusted at the sprayer using the fluid flow regulator handle and the value is shown on the display. ADJUSTING THE AIR • In order to decrease the air flow, turn the regulator anticlockwise (P1).
Page 18
PEGASO CLEANING UP AFTER WORK • Reduce pressure to the minimum (turn counter- clockwise the pressure control knob) (1). • Empty remaining material into bucket until most of texture material is out of hopper (2). MATERIAL • Fill the tank with clean water (3), or connect a flexible...
Page 19
PEGASO CLEANING THE MATERIAL PASSAGE HOSE ☞ PLEASE NOTE Suggested before storing the sprayer or when changing the material to be sprayed. Disconnect the material feed hose and the air feed hose from the gun; Disconnect the flexible material passage hose from the sprayer;...
PEGASO PROCEDURE OF DECOMPRESSION • After having carried out all the operations described in the chapter concerning cleaning up after work, make sure that the system is not pressurised. • Squeeze the trigger and wait for all the material to have come out.
PEGASO ROUTINE MAINTENANCE • To keep sprayer in good operating condition, always clean it thoroughly and prepare it properly for storage. The air hose fitting on sprayer can get hot! Allow sprayer to cool down 5 minutes before removing air hose.
PEGASO PROCEDURE FOR REPLACING THE HOSE 3) Loosen the lower metal clamp (B) (photo 3). WARNING Before starting to replace the hose, accura- tely clean the machine. REMOVAL 1) Remove the side casing (photo 1). Photo 3 4) Remove the front plate (C), remove the two bolts (D) (photo 4).
Page 23
PEGASO 6) Start the machine, switch (F) on “1”; Start the pump, switch (G) on “ON”. Slightly increase the pressure of the pump by rotating the potentiometer (H) clockwise, the reading of the value is shown on the upper display (photo 6).
Page 24
PEGASO WARNING If it is necessary to remove the pump from the machine, it is necessary to: • Remove the side casing (A). • Loosen the metal clamps (B) (C). • Remove the two attachment bolts (D). • Pull the pump, holding it by the handle fashio- ned inside the support.
PEGASO CLEANING AND REPLACING THE SENSOR CLEANING 3) Turn on the spray gun and the pump, let the water CLEANING circulate first in one direction and then the other, in- 1) If present, insert a flexible hose (A), connected to the verting the rotation of the pump (“PUMP ROTATION”...
PEGASO PROBLEMS AND SOLUTIONS Solution Problem Cause • Make sure the power line is connec- • The apparatus doesn’t start • Lack of power; ted properly; • Check the extension cord; • Strong drops in network voltage; • Ensure the On/Off switch is on the •...
Page 27
PEGASO Solution Problem Cause • Thin material; • Speed of application too slow • Material too thick; • Change nozzles to a larger size. See • Nozzle too small; Operation Manual, Recommended Nozzle Selection Chart; • Increase flow control setting;...
PEGASO SPARE PARTS TABLE PAGE Group Group strutures RIF. 30566 Group reservoir RIF. 30560 Group of control RIF. 30569 Group compressor RIF. 30564 Group valves RIF. 30562 Group pumps RIF. 30561 Group of control air RIF. 30565 Group reservoir air RIF. 30563 Group gun Turbo Gun RIF.
Page 30
PEGASO TABLE 02 - GROUP RESERVOIR RIF. 30560 Pos. Code Description Pos. Code Description 18249/1 Cover tank 20833 Elbow 18249 Tank 50L 30503 Rapid attachment 18246 Tank Support 20842 Rapid attachment 901568 Screw 30552 Clamp 34009 Wascher 30576 Suction hose...
Page 31
PEGASO TABLE 03 - GROUP OF CONTROL RIF. 30569 GROUP OF CONTROL RIF. 30569 / 110 V Pos. Code Description Pos. Code Description 30514 Support 30546 Panel of closing 34009 Wascher 30523 Adhesive panel 8371 Screw 96028 Screw 30545 30547...
Page 46
MANUFACTURER: 23801 CALOLZIOCORTE - LECCO - ITALY - Via Stoppani, 21 Tel. (39) 0341/62.11.52 - Fax (39) 0341/62.12.43 E-mail: larius@larius.com - Internet http://www.larius.com DIRECT LINE CUSTOMERS TECHNICAL SERVICE Tel. (39) 0341/621256 Fax (39) 0341/621234 Due to a constant product improvement programme, the factory reserves the right to modify...