Setting parameters for blocks
3.4 Programming Ident blocks
Table 3- 40
ATTRIBUTE "0x87" (data type "IID_READSTAT_87_RF600")
Name
status info
hardware
hardware version
reserved0
firmware
firmware version HB
firmware version LB
driver
current_time_hour
current time min
current time sec
reserved1
SLG version
baud
reserved2
distance limiting SLG
multitag SLG
field ON control SLG
field ON time SLG
expert mode
status_ant
scanning_time_SLG
MDS control
The internal time stamp of the reader that relates to this event is output. The internal reader time stamp is not synchro-
1)
nized with UTC.
The antenna status relates to the "ATTRIBUTE" (bits 0 and 1) of the last executed "SET-ANT" or to the default value set
2)
by "INIT"/"WRITE-CONFIG". With "INIT"/"WRITE-CONFIG" of the RF620R, the default value is "1" (int. antenna on),
with the RF630R, it is "3" (antennas 1 and 2 on).
Table 3- 41
ATTRIBUTE "0x88" (data type "IID_READSTAT_88_RF600")
Name
status info
hardware
hardware version
reserved word1
firmware
firmware version HB
firmware version LB
driver
current_time_hour
current_time_minute
current_time_sec
current_time_reservByte
SLG version
baud
reserved byte1
distance limiting SLG
multitag SLG
field ON control SLG
field ON time SLG
60
Type
Comment
BYTE
SLG status mode
CHAR
Type of hardware
WORD
Version of hardware
WORD
CHAR
Type of firmware
BYTE
Version of firmware highbyte
BYTE
Version of firmware lowbyte
CHAR
Type of driver
BYTE
Hours
BYTE
Minutes
BYTE
Seconds
BYTE
BYTE
SLG version
BYTE
Baudrate
BYTE
BYTE
Selected transmit power
BYTE
Multitag SLG
BYTE
Selected comunication typ
BYTE
Selected channel
BYTE
Expert mode
BYTE
Status of antenna
BYTE
Radio communication profile (country specific radio
standart)
BYTE
Presence mode
Type
Comment
BYTE
SLG status mode(Subcommand)
CHAR
Type of hardware
WORD
Version of hardware
WORD
Reserved
CHAR
Type of firmware
BYTE
Version of firmware (High-Byte)
BYTE
Version of firmware (Low-Byte)
CHAR
Type of driver
BYTE
Hours
BYTE
Minutes
BYTE
Seconds
BYTE
BYTE
SLG-Version
BYTE
Baudrate
BYTE
Reserved
BYTE
Selected transmit power
BYTE
Multitag SLG
BYTE
Selected communication type
BYTE
Selected channel
1)
2)
1)
1)
1)
Ident profile and Ident blocks, standard function for Ident systems
Function Manual, 10/2018, C79000-G8976-C387-04