Download Print this page
Honeywell SiX Series Installation Instructions
Honeywell SiX Series Installation Instructions

Honeywell SiX Series Installation Instructions

1-button wireless key
Hide thumbs Also See for SiX Series:

Advertisement

Quick Links

SiXMEDICAL
1-Button Wireless Key

Installation Instructions

This bi-directional wireless key is intended for
use with Honeywell controls that support SiX™
series devices.
To activate, press and hold the button about 3
seconds until the LED flashes. To clear the alarm
at the control, enter a user code. To clear
memory of alarm, select Disarm and enter a user
code.
Enroll and Program the SiXMEDICAL
For the Lyric™ Controller
Follow instructions in the Controller's programming guide.
1. Set the Lyric Controller in Programming Mode: Security >
Tools > [installer code] > Program > (scroll down) > SiX
Programming.
2. Press and hold the button for about 3 seconds until the LED
flashes to activate the enrollment process.
3. The LED flashes green during enrollment (up to about 20
seconds).
NOTE: Enrollment time varies depending on the signal
strength between the device and the controller.
• The device sends its unique MAC ID (Serial Number) and
Services information to the controller.
• The controller registers the device and displays the
transmitter data on screen.
4. When done, the LED lights solid green for 3 seconds to
confirm enrollment.
If enrollment is not confirmed, press and hold the button again
for about 3 seconds to restart the enrollment process.
5. Press Edit to set the Alarm Report option on/off (if selected,
button press sends a report to the central station). Press
Save. Enter an appropriate Zone Descriptor. Press Save.
The device can also be manually enrolled. See the Controller's
Programming Guide for details.
For the Lyric™ Gateway
Enroll and program using AlarmNet 360™.
For other Controls
For other Controls that support SiX Series devices, see the
controller's instructions for enrollment details.
24-Hour Enrollment Deletion and Default
If the device is enrolled in a panel different than the
intended panel, and you are unable to delete it from the
unintended panel, reset the device to factory default
setting:
Press and hold the button for 15 seconds.
The device self-deletes from the panel it was enrolled in.
This procedure is available for 24 hours after enrollment
with a panel and the device remains powered (battery
installed).
The device can be used with a belt clip, lanyard,
or wristband.
[images of belt clip, wristband, necklace]
LED Indications
Green flashing: lights when unit is transmitting
Red Flashing: indicates low battery (lights
IMPORTANT: Once enrolled in a system, the SiXMEDICAL
cannot be used with another controller until it is removed from the
current controller. When removed from a system, the key fob will
revert to factory default settings.
Sensor Location Feature: To verify the location of each SiX
device in an installation, enter programming mode and select a
SiX device. The device LED lights. Select it again to turn the LED
off, or select the next device to locate.
After Enrolling: Verify adequate signal strength by conducting
Go/No Go tests (see controller's instructions) with the device in
its intended mounting location. Adjust the device location as
necessary.
Press and hold button 15 seconds.
during key press)

Advertisement

loading

Summary of Contents for Honeywell SiX Series

  • Page 1: Installation Instructions

    For other Controls After Enrolling: Verify adequate signal strength by conducting For other Controls that support SiX Series devices, see the Go/No Go tests (see controller’s instructions) with the device in controller’s instructions for enrollment details.
  • Page 2: Battery Replacement

    For patent information, see www.honeywell.com/patents Patents MyWebTech Warranty  2018 Honeywell International Inc. Honeywell and is a registered trademark of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. www.honeywell.com/security DOC CODE 128B BAR CODE HERE 2 Corporate Center Drive, Suite 100 P.O.

This manual is also suitable for:

Sixmedical