Disconnecting from the mains
Risk of electric shock.
There is a risk of electric shock if the
hob is connected to the mains
supply during repair or service work.
After disconnection, ensure the
appliance cannot be switched back
on by mistake.
To disconnect the appliance from the
mains power supply, do one of the
following depending on installation:
Safety fuses
 Completely remove fuses.
Automatic circuit breakers
 Press the (red) test button until the
middle (black) button springs out.
Built-in circuit breakers
 Circuit breakers at least type B or C:
Switch the lever from 1 (on) to 0 (off).
Residual current device (RCD)
 Switch the main switch from 1 (on) to
0 (off) or press the test button.
Electrical connection
Replacing the mains cable
Danger of electric shock.
The mains connection cable must be
replaced by a registered electrical
worker in accordance with current
local safety regulations.
If the mains cable needs to be replaced
it must be replaced with a special
connection cable, type H 05 VV-F (PVC-
insulated), available from Miele.
The connection data is quoted on the
data plate.