Location Of The Appliance; Covering Terminal Board; Levelling Of The Appliance; Electrical Installation - Zanussi ZCI66050BA User Manual

Table of Contents

Advertisement

LOCATION OF THE APPLIANCE

You can install your freestanding appliance with
cabinets on one or two sides and in the corner.
Minimum distances
Dimension
A

LEVELLING OF THE APPLIANCE

Use small feet on the bottom of appliance to set the
appliance top surface level with other surfaces.

ELECTRICAL INSTALLATION

WARNING! The manufacturer is not
responsible if you do not follow the
safety precautions from Safety
chapters.
This appliance is supplied without a main plug or a
main cable.
Applicable types of cables for different
phases:
Phase
1
A
mm
685
Min. size cable
3x6.0 mm²
Phase
3 with neutral
WARNING! The power cable must
not touch the part of the appliance
shaded in the illustration.

COVERING TERMINAL BOARD

The recommended cross-section area is six
square millimetres (6 mm²).
When you refit the mains terminal cover, make
sure that the lower tabs are located inside the
bottom edge of the aperture, before you fix the
two screws into the top edge of the mains
terminal cover.
Make sure that the cover is securely fastened.
To open the cover of terminal board
obey the procedure in opposite
sequence.
TERMINAL BOARD
Do not remove blanking plates.
Make sure that the links are fitted as shown.
Min. size cable
5x1.5 mm²
25