AIRE® Portable Air Scrubber. These instructions must be carefully followed in order to operate the units safely and correctly. If you have any questions regarding the use or care of this equipment call Abatement Technologies at +1 800-634-9091 (U.S.) or +1 905-871-4720 (Canada) for assistance.
Warning: To reduce the risk of fire, electric shock, or injury to person observe the following: Use this unit only in the manner intended by Abatement Technologies. If you have questions, contact Abatement Technologies at +1 800-634-9091 (U.S.) or +1 905-871-4720 (Canada).
Warning: Do not connect the unit’s power cord to a supply receptacle unless the inlet and power modules are in their proper position and latched together. Warning: Abatement Technologies air filtration systems are not intrinsically safe for use in hazardous environments. Always consult a certified industrial hygienist before using them. Do NOT use this...
OVG can occur when the adsorption capacity of the filter is reached, replace the carbon filter as soon as odor breakthrough is sensed. More detailed information on carbon adsorption can be found in an article titled: “Activated Carbon: How Is It Used? How Does It Work?” which can be found on the Abatement Technologies website, www.abatement.com.
ELECTRICAL REQUIREMENTS 1. The PAS1200s require a minimum of 110 volts AC, 60 Hz to operate properly; however, maximum air flow performance requires 120 volts AC, 60 Hz. 2. Due to momentary start-up current surge, the unit requires a 15 amp circuit that is free of other loads. 3.
If the room air filtration units are being used to create and maintain a negative/positive pressure condition, the pressure differential between the negative/positive room and the environment outside the room should be monitored with a calibrated instrument as per OSHA/CDC requirements. The Abatement Technologies Portable Pressure Monitors are recommended to ensure that requirements are being met.
USER SERVICING INSTRUCTIONS Abatement Technologies’ portable air scrubbers are designed to be low maintenance devices and basic maintenance should be performed as follows: Filters should be changed as needed based on the filter change indicator light. Follow the FILTER •...
Note: The filters are not reusable, therefore, do not attempt to clean and reuse them. Caution: Abatement Technologies HEPA-AIRE® Portable Air Scrubber units are designed to meet or exceed standards for high efficiency air filtration equipment. Use only Abatement Technologies parts, including replacement filters.
6. Tighten the filter retaining bolts and reattach the HEPA filter access panel. Warning: Use only Abatement Technologies pre-filters, HEPA filters, and replacement parts. Substitute parts void the warranty, jeopardize worker and environmental safety, and adversely affect engineered performance levels.
PAS1200 SPECIFICATIONS FEATURE SPECIFICATIONS Net weight with filters: 85 lbs. Shipping weight: 107 lbs. Unit dimensions: 19.75” L x 22” W x 39” H Power supply requirements: Minimum 120 VAC, 60 Hz, 15 A Normal operating amps: 3.5 amps or less Integrated circuit breaker: 10 amps 400 watt motorized impeller with thermal overload protection,...
Remove carbon filter from polybag. removed from polybag. Note: If the unit does not start or malfunctions after carefully following the TROUBLESHOOTING GUIDE, call Abatement Technologies service department at +1 800-634-9091 (U.S.) or +1 905-871-4720 (Canada) for assistance.
Nationally Recognized Testing Laboratory (NRTL). LIMITED WARRANTY Abatement Technologies, Inc (ATI) warrants that goods sold to the original user shall be free from defects in material and workmanship for a period of 1 year, except such as are commercially acceptable. This warranty does not include useful filter life.