Download Print this page
Smeg PU64 Installation Manual

Smeg PU64 Installation Manual

Smeg cooktop installation guide
Hide thumbs Also See for PU64:

Advertisement

Quick Links

1. IMPORTANT SAFETY INSTRUCTIONS ................................................................................. 4
2. COOKTOP MEASUREMENTS ............................................................................................... 5
3. POSITIONING THE COOKTOP AND LOCATION REQUIREMENTS .................................... 6
3.1 Gas supply requirements ................................................................................................................................ 8
3.2 Electrical requirements .................................................................................................................................... 9
4. INSTALLING THE COOKTOP ............................................................................................... 11
5. CHECKING OPERATION ...................................................................................................... 14
6. WIRING DIAGRAMS ............................................................................................................. 15
INSTRUCTIONS FOR THE INSTALLER: these are intended for the qualified engineer who is able to
install, commission and test the appliance

Table of Contents

3

Advertisement

loading

Summary of Contents for Smeg PU64

  • Page 1: Table Of Contents

    1. IMPORTANT SAFETY INSTRUCTIONS ... 4 2. COOKTOP MEASUREMENTS ... 5 3. POSITIONING THE COOKTOP AND LOCATION REQUIREMENTS ... 6 3.1 Gas supply requirements ... 8 3.2 Electrical requirements ... 9 4. INSTALLING THE COOKTOP ... 11 5. CHECKING OPERATION ... 14 6.
  • Page 2: Important Safety Instructions

    Installation and service must be performed by a qualified installer, service agency or the gas supplier. NOTE: This cooktop is manufactured for use with Natural gas. To convert to LP/Propane gas, see instructions in the Gas Conversion Kit provided in the literature package.
  • Page 3: Cooktop Measurements

    Instructions for the Installer 2. COOKTOP MEASUREMENTS...
  • Page 4: Positioning The Cooktop And Location Requirements

    It is the installer’s responsibility to comply with installations guidelines specified on the model/serial rating plate. The model/serial rating plate is located on the underside of the cooktop burner box. The cooktop should be installed in a location away from strong draft areas, such as windows, doors and strong heating vents or fans.
  • Page 5 Cooktop widht ” ” - 22 ” 600 mm 565 - 569 mm ” ” - 22 ” 700 mm 565 - 569 mm ” ” - 33 ” 1000 mm 855 - 860 mm Gas line opening Wall: everywhere, 5” (12.7 cm) below underside of countertop.
  • Page 6: Gas Supply Requirements

    If local codes permit, a flexible metal appliance connector with the new AGA- or CSAcertified design, 4-5 feet (1.2-1.5 m) long, 1/2" or 3/4" I.D., is recommended for connecting this cooktop to the gas supply line. Do not bend or damage the flexible connector when moving the cooktop. The pressure regulator has 3/8 female pipe threads.
  • Page 7: Electrical Requirements

    Testing below 112 PSI (3.5 kPa) with a water column of 14” (35.6 cm) (gauge) or lower. The cooktop must be isolated from the gas supply piping system by closing the respective manual shut- off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
  • Page 8 Instructions for the Installer 3.2.1 Recommended Grounding Method For your personal safety, this cooktop must be grounded. This cooktop is equipped with a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with the National ANSI/NFPA 70 Electrical Code (latest edition*) or the Canadian Electrical Code (CSA)** and local codes and ordinances.
  • Page 9: Installing The Cooktop

    4. INSTALLING THE COOKTOP Remove the upper polystyrene guard and the side guards. Remove the grids, the nylon sheet serving to protect the cooktop during shipping and the burner crowns. These parts could make product assembly more difficult. Connection to the gas mains may be made with a flexible metal pipe and conforming to the provisions defined by current standard regulations in force.
  • Page 10 Secure the cooktop to the counter with brackets A (supplied). Carefully trim any excess from edge B on the gasket. The distances in the following drawing refer to the hole on the inner side of the gasket. The diagram below shows the exact positions of the holes to be used for clamping the hob to the top by the brackets correctly.
  • Page 11 Always use pipe-joint compound made for use with NATURAL GAS and L.P. GAS between pressure regulator D and adaptator C and between pressure regulator D and pipe E. If flexible metal conductor is used, be certain tubing is not kinked. Use only pipes (E) conforming to standard regulations in force, inserting gasket B (supplied) between fitting A adaptator C.
  • Page 12: Checking Operation

    5. CHECKING OPERATION After having fastened the top to the support structure, some simple procedures are required to check for proper operation. Check for any gas leaks in the vicinity of the cooktop connector, the pressure regulator and the safety valve. WARNING NOTE: The regulator Is fitted with a checkpoint outlet gas pressure to check the exact pressure supplied to the appliance.
  • Page 13: Wiring Diagrams

    Instructions for the Installer 6. WIRING DIAGRAMS The power cord on this appliance is equipped with a threee pronge polarized plug (grounding) which mates with standard three pronged (grounding) wall receptacles. Label all wires prior to disconnection when servicing controls. WARNING Wiring errors can cause improper and dangerous operation.
  • Page 14 The power cord on this appliance is equipped with a threee pronge polarized plug (grounding) which mates with standard three pronged (grounding) wall receptacles. WARNING Instructions for the Installer Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
  • Page 15 Instructions for the Installer The power cord on this appliance is equipped with a threee pronge polarized plug (grounding) which mates with standard three pronged (grounding) wall receptacles. Label all wires prior to disconnection when servicing controls. WARNING Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

This manual is also suitable for: