Cisco Catalyst 3550 Command Reference Manual

Cisco Catalyst 3550 Command Reference Manual

Multilayer switch
Hide thumbs Also See for Catalyst 3550:
Table of Contents

Advertisement

Catalyst 3550 Multilayer Switch
Command Reference
Cisco IOS Release 12.1(19)EA1
October 2003
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
Customer Order Number: DOC-7811195=
Text Part Number: 78-11195-09

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Catalyst 3550

  • Page 1 Catalyst 3550 Multilayer Switch Command Reference Cisco IOS Release 12.1(19)EA1 October 2003 Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 526-4100 Customer Order Number: DOC-7811195= Text Part Number: 78-11195-09...
  • Page 2 CCIP, CCSP, the Cisco Arrow logo, the Cisco Powered Network mark, Cisco Unity, Follow Me Browsing, FormShare, and StackWise are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn, and iQuick Study are service marks of Cisco Systems, Inc.; and Aironet, ASIST, BPX, Catalyst, CCDA, CCDP, CCIE,...
  • Page 3: Table Of Contents

    Global Configuration Mode Interface Configuration Mode config-vlan Mode VLAN Configuration Mode Line Configuration Mode Cisco IOS Commands C H A P T E R aaa authentication dot1x access-list hardware program nonblocking action archive download-sw Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 4 2-46 clear vtp counters 2-47 cluster commander-address 2-48 cluster discovery hop-count 2-50 cluster enable 2-51 cluster holdtime 2-53 cluster member 2-54 cluster outside-interface 2-56 cluster run 2-57 cluster standby-group 2-58 cluster timer 2-60 Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 5 2-107 ip dhcp snooping trust 2-108 ip dhcp snooping vlan 2-109 ip igmp filter 2-110 ip igmp max-groups 2-112 ip igmp profile 2-114 ip igmp snooping 2-116 ip igmp snooping report-suppression 2-119 Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 6 2-171 mls qos min-reserve 2-174 mls qos monitor 2-175 mls qos trust 2-177 monitor session 2-179 mvr (global configuration) 2-183 mvr (interface configuration) 2-186 pagp learn-method 2-189 pagp port-priority 2-191 Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 7 2-248 show controllers tcam 2-249 show dot1q-tunnel 2-251 show dot1x 2-252 show env 2-255 show errdisable detect 2-257 show errdisable flap-values 2-258 show errdisable recovery 2-260 show etherchannel 2-262 show fm 2-265 Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 8 2-327 show mls qos maps 2-331 show monitor 2-334 show mvr 2-336 show mvr interface 2-338 show mvr members 2-340 show pagp 2-342 show parser macro 2-344 show policy-map 2-346 Catalyst 3550 Multilayer Switch Command Reference viii 78-11195-09...
  • Page 9 2-406 spanning-tree bpduguard 2-408 spanning-tree cost 2-410 spanning-tree etherchannel guard misconfig 2-412 spanning-tree extend system-id 2-414 spanning-tree guard 2-416 spanning-tree link-type 2-418 spanning-tree loopguard default 2-419 spanning-tree mode 2-421 spanning-tree mst configuration 2-423 Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 10 2-471 switchport priority extend 2-473 switchport protected 2-475 switchport trunk 2-476 switchport unicast 2-480 switchport voice vlan 2-481 system mtu 2-483 traceroute mac 2-485 traceroute mac ip 2-488 trust 2-490 Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 11 2-540 wrr-queue random-detect max-threshold 2-541 wrr-queue threshold 2-543 Boot Loader Commands A P P E N D I X boot copy delete flash_init format fsck A-10 help A-11 load_helper A-12 memory A-13 Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 12 B-18 debug l3tcam B-19 debug l3unicast B-20 debug mac-manager B-21 debug mac-notification B-22 debug met B-23 debug mvrdbg B-24 debug pagp B-25 debug pbr B-26 debug pm B-27 debug port-security B-29 Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 13 B-36 debug spanning-tree switch B-38 debug spanning-tree uplinkfast B-40 debug sw-vlan B-41 debug sw-vlan ifs B-43 debug sw-vlan notification B-44 debug sw-vlan vtp B-45 debug udld B-47 N D E X Catalyst 3550 Multilayer Switch Command Reference xiii 78-11195-09...
  • Page 14 Contents Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 15 This guide provides the information you need about the Layer 2 and Layer 3 commands that have been created or changed for use with the Catalyst 3550 family of switches. For information about the standard Cisco IOS Release 12.1 commands, refer to the Cisco IOS documentation set available from the Cisco.com home page by selecting Service and Support >...
  • Page 16 Means reader be careful. In this situation, you might do something that could result equipment damage Caution or loss of data. Timesaver Means the following will help you solve a problem. The tips information might not be troubleshooting or even an action, but could be useful information. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 17 These documents provide complete information about the switch and are available from this Cisco.com site: http://www.cisco.com/univercd/cc/td/doc/product/lan/c3550/index.htm You can order printed copies of documents with a DOC-xxxxxx= number from the Cisco.com site and from the telephone numbers listed in the“Obtaining Documentation” section on page xvii.
  • Page 18 For all customers, partners, resellers, and distributors who hold valid Cisco service contracts, the Cisco Technical Assistance Center (TAC) provides 24-hour, award-winning technical support services, online and over the phone. Cisco.com features the Cisco TAC website as an online starting point for technical assistance.
  • Page 19 24 hours a day, 365 days a year. Accessing all the tools on the Cisco TAC website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a login ID or password, register at this URL: http://tools.cisco.com/RPF/register/register.do...
  • Page 20 • and experienced users: Internetworking Terms and Acronyms Dictionary, Internetworking Technology Handbook, Internetworking Troubleshooting Guide, and the Internetworking Design Guide. For current Cisco Press titles and other information, go to Cisco Press online at this URL: http://www.ciscopress.com • Packet magazine is the Cisco quarterly publication that provides the latest networking trends, technology breakthroughs, and Cisco products and solutions to help industry professionals get the most from their networking investment.
  • Page 21: Type Of Memory

    C H A P T E R Using the Command-Line Interface The Catalyst 3550 multilayer switches are supported by Cisco IOS software. This chapter describes how to use the switch command-line interface (CLI) to configure software features. For a complete description of the commands that support these features, see Chapter 2, “Cisco IOS...
  • Page 22: C H A P T E R 1 Using The Command-Line Interface

    From global configuration mode, To exit to global configuration mode, Switch(config-line)# specify a line by entering the line enter the exit command. command. To return to privileged EXEC mode, enter the end command, or press Ctrl-Z. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 23: User Exec Mode

    You can specify either the terminal or nonvolatile RAM (NVRAM) as the source of configuration commands. This example shows you how to access global configuration mode: Switch# configure terminal Enter configuration commands, one per line. End with CNTL/Z. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 24: Interface Configuration Mode

    For extended-range VLANs, all characteristics except the MTU size must remain at the default setting. To return to global configuration mode, enter exit; to return to privileged EXEC mode, enter end. All the commands except shutdown take effect when you exit config-vlan mode. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 25: Vlan Configuration Mode

    To exit line configuration mode and to return to global configuration mode, use the exit command. To exit line configuration mode and to return to privileged EXEC mode, enter the end command, or press Ctrl-Z. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 26 Chapter 1 Using the Command-Line Interface CLI Command Modes Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 27 The client is automatically authenticated by the switch without using the information supplied by the client. Defaults No authentication is performed. Command Modes Global configuration Command History Release Modification 12.1(8)EA1 This command was first introduced. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 28: Chapter 2 Cisco Io Command

    The remaining methods enable AAA to authenticate the client by using locally configured data. For example, the local and local-case methods use the username and password that are saved in the Cisco IOS configuration file. The enable and line methods use the enable and line passwords for authentication.
  • Page 29 This example shows how to set the system to continue forwarding frames while a new security ACL configuration is being programmed into hardware: Switch (config)# access-list hardware program nonblocking You can verify your setting by entering the show running-config | include access-list hardware privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 30: Access-List Hardware Program Nonblocking

    Related Commands Command Description access-list {deny | permit} Configures a standard numbered ACL. For syntax information, select Cisco IOS IP and IP Routing Command Reference for IOS Release 12.1 > IP Addressing and Services > IP Services Commands. action (access map Defines or modifies the action for the VLAN access map entry.
  • Page 31 Switch(config)# vlan access-map vmap4 Switch(config-access-map)# match ip address al2 Switch(config-access-map)# action forward Switch(config-access-map)# exit Switch(config)# vlan filter vmap4 vlan-list 5-6 You can verify your settings by entering the show vlan access-map privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 32: Action

    Command Description access-list {deny | permit} Configures a standard numbered ACL. For syntax information, select Cisco IOS IP and IP Routing Command Reference for IOS Release 12.1 > IP Addressing and Services > IP Services Commands. ip access-list Creates a named access list. For syntax information, select Cisco IOS IP and IP Routing Command Reference for IOS Release 12.1...
  • Page 33 The BOOT environment variable is changed to point to the new software image on the flash: file system. Image names are case sensitive; the image file is provided in tar format. Command Modes Privileged EXEC Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 34: Archive Download-Sw

    The /imageonly option removes the HTML files for the existing image if the existing image is being removed or replaced. Only the Cisco IOS image (without the HTML files) is downloaded. Using the /safe or /leave-old-sw option can cause the new image download to fail if there is insufficient Flash space.
  • Page 35: Archive Tar

    An optional list of files or directories within the source directory can be specified to write to the new tar file. If none are specified, all files and directories at this level are written to the newly created tar file. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 36 If none are specified, all files and directories are extracted. Defaults None Command Modes Privileged EXEC Command History Release Modification 12.1(4)EA1 This command was first introduced. Usage Guidelines Filenames and directory names are case sensitive. Image names are case sensitive. Catalyst 3550 Multilayer Switch Command Reference 2-10 78-11195-09...
  • Page 37 Switch# archive tar /xtract tftp:/172.20.10.30/saved.tar flash:/ new-configs Related Commands Command Description archive download-sw Downloads a new image to the switch. archive upload-sw Uploads an existing image on the switch to a server. Catalyst 3550 Multilayer Switch Command Reference 2-11 78-11195-09...
  • Page 38: Archive Upload-Sw

    The upload feature is available only if the HTML files associated with the Cluster Management Suite (CMS) have been installed with the existing image. The files are uploaded in this sequence: info, the Cisco IOS image, the HTML files, and info.ver. After these files are uploaded, the software creates the tar file.
  • Page 39 Command Description archive download-sw Downloads a new image to the switch. archive tar Creates a tar file, lists the files in a tar file, or extracts the files from a tar file. Catalyst 3550 Multilayer Switch Command Reference 2-13 78-11195-09...
  • Page 40: Auto Qos Voip

    {cisco-phone | trust} no auto qos voip Syntax Description cisco-phone Identify this interface as connected to a Cisco IP phone, and automatically configure QoS for VoIP. The QoS labels of incoming packets are trusted only when the telephone is detected. trust Identify this interface as connected to a trusted switch or router, and automatically configure QoS for VoIP.
  • Page 41 Cisco IP phone. When a Cisco IP phone is detected, the ingress classification on the interface is set to trust the QoS label received in the packet. When a Cisco IP phone is absent, the ingress classification is set to not trust the QoS label in the packet. The egress queues on the...
  • Page 42 Switch(config-if)# auto qos voip trust This example shows how to enable auto-QoS and to trust the QoS labels received in incoming packets when the device connected to Fast Ethernet interface 0/1 is detected as a Cisco IP phone: Switch(config)# interface fastethernet0/1...
  • Page 43 Displays auto-QoS information. show mls qos Displays global QoS configuration information. show mls qos interface Displays QoS information at the interface level. show mls qos maps Displays QoS mapping information. Catalyst 3550 Multilayer Switch Command Reference 2-17 78-11195-09...
  • Page 44: Boot Boothlpr

    Use the boot boothlpr global configuration command to load a special Cisco IOS image, which when loaded into memory, can load a second Cisco IOS image into memory and launch it. This variable is used only for internal development and testing. Use the no form of this command to return to the default setting.
  • Page 45: Boot Buffersize

    This command changes the setting of the CONFIG_BUFSIZE environment variable. For more information, see Appendix A, “Boot Loader Commands.” Related Commands Command Description show boot Displays the settings of the boot environment variables. Catalyst 3550 Multilayer Switch Command Reference 2-19 78-11195-09...
  • Page 46: Boot Config-File

    Use the boot config-file global configuration command to specify the filename that Cisco IOS uses to read and write a nonvolatile copy of the system configuration. Use the no form of this command to return to the default setting.
  • Page 47: Boot Enable-Break

    This command changes the setting of the ENABLE_BREAK environment variable. For more information, see Appendix A, “Boot Loader Commands.” Related Commands Command Description show boot Displays the settings of the boot environment variables. Catalyst 3550 Multilayer Switch Command Reference 2-21 78-11195-09...
  • Page 48: Boot Helper

    This command changes the setting of the HELPER environment variable. For more information, see Appendix A, “Boot Loader Commands.” Related Commands Command Description show boot Displays the settings of the boot environment variables. Catalyst 3550 Multilayer Switch Command Reference 2-22 78-11195-09...
  • Page 49: Boot Helper-Config-File

    Use the boot helper-config-file global configuration command to specify the name of the configuration file to be used by the Cisco IOS helper image. If this is not set, the file specified by the CONFIG_FILE environment variable is used by all versions of Cisco IOS that are loaded. This variable is used only for internal development and testing.
  • Page 50: Boot Manual

    This command changes the setting of the MANUAL_BOOT environment variable. For more information, see Appendix A, “Boot Loader Commands.” Related Commands Command Description show boot Displays the settings of the boot environment variables. Catalyst 3550 Multilayer Switch Command Reference 2-24 78-11195-09...
  • Page 51: Boot Private-Config-File

    12.1(11)EA1 This command was first introduced. Usage Guidelines Only the Cisco IOS software can read and write a copy of the private configuration file. You cannot read, write, delete, or display a copy of this file. Filenames are case sensitive.
  • Page 52: Boot System

    Use the boot system global configuration command to specify the Cisco IOS image to load during the next boot cycle. Use the no form of this command to return to the default setting. boot system filesystem:/file-url ...
  • Page 53: Channel-Group

    LACP packets it receives but does not initiate LACP packet negotiation. A channel is formed only with another port group in active mode. When passive is enabled, silent operation is the default. Catalyst 3550 Multilayer Switch Command Reference 2-27 78-11195-09...
  • Page 54 802.1X on an EtherChannel or on an active port in an EtherChannel, an error message appears, and 802.1X is not enabled. If you enable 802.1X on a not-yet active port of an EtherChannel, the port does not join the EtherChannel. Catalyst 3550 Multilayer Switch Command Reference 2-28 78-11195-09...
  • Page 55 Display LACP information. show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-29...
  • Page 56: Channel-Protocol

    This example shows how to set an EtherChannel into PAgP mode: Switch(config-if)# channel-protocol pagp This example shows how to set an EtherChannel into LACP mode: Switch(config-if)# channel-protocol lacp You can verify your settings by entering the show running-config privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-30 78-11195-09...
  • Page 57 Display LACP information. show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-31...
  • Page 58: Class

    After you enter the class command, the switch enters policy-map class configuration mode, and these configuration commands are available: bandwidth: Although this command appears, it is not supported on Catalyst 3550 switches. • •...
  • Page 59 Creates or modifies a policy map that can be attached to multiple interfaces to specify a service policy. show policy-map Displays quality of service (QoS) policy maps. Catalyst 3550 Multilayer Switch Command Reference 2-33 78-11195-09...
  • Page 60: Class-Map

    If you rename a class map with a name that is already in • use, this message appears: A class-map with this name already exists Catalyst 3550 Multilayer Switch Command Reference 2-34 78-11195-09...
  • Page 61 Defines the match criteria to classify traffic. policy-map Creates or modifies a policy map that can be attached to multiple interfaces to specify a service policy. show class-map Displays QoS class maps. Catalyst 3550 Multilayer Switch Command Reference 2-35 78-11195-09...
  • Page 62: Clear Lacp

    This example shows how to clear channel-group traffic counters: Switch# clear lacp counters You can verify that the information was deleted by entering the show lacp privileged EXEC command. Related Commands Command Description show lacp Displays LACP channel-group information. Catalyst 3550 Multilayer Switch Command Reference 2-36 78-11195-09...
  • Page 63: Clear L2Protocol-Tunnel Counters

    This example shows how to clear Layer 2 protocol tunnel counters for Gigabit Ethernet interface 0/3: Switch # clear l2protocol-tunnel counters gigabitethernet0/3 Related Commands Command Description show l2protocol-tunnel Displays information about ports configured for Layer 2 protocol tunneling. Catalyst 3550 Multilayer Switch Command Reference 2-37 78-11195-09...
  • Page 64: Clear Mac Address-Table

    VLAN. This command also clears the MAC address notification global counters. clear mac address-table {dynamic [address mac-addr | interface interface-id | vlan vlan-id] | notification} Beginning with Cisco IOS Release 12.1(11)EA1, the clear mac address-table command replaces the Note clear mac- address-table command (with the hyphen).
  • Page 65 Displays the MAC address notification settings for all interfaces or the specified interface. snmp trap mac-notification Enables the Simple Network Management Protocol (SNMP) MAC address notification trap on a specific interface. Catalyst 3550 Multilayer Switch Command Reference 2-39 78-11195-09...
  • Page 66: Clear Pagp

    This example shows how to clear channel-group traffic filters: Switch# clear pagp counters You can verify that information was deleted by entering the show pagp privileged EXEC command. Related Commands Command Description show pagp Displays PAgP channel-group information. Catalyst 3550 Multilayer Switch Command Reference 2-40 78-11195-09...
  • Page 67: Clear Port-Security

    If you enter the clear port-security sticky command, the switch removes all sticky secure MAC addresses from the MAC address table. Command History Release Modification 12.1(11)EA1 This command was first introduced. 12.1(14)EA1 The all, configured, and vlan keywords were added. Catalyst 3550 Multilayer Switch Command Reference 2-41 78-11195-09...
  • Page 68 You can verify that the information was deleted by entering the show port-security privileged EXEC command. Related Commands Command Description show port-security Displays the port security settings for an interface or for the switch. switchport port-security Enables port security on an interface. Catalyst 3550 Multilayer Switch Command Reference 2-42 78-11195-09...
  • Page 69: Clear Setup Express

    You can verify that the switch has exited Express Setup mode by entering the show express setup privileged EXEC command. Related Commands Command Description setup express Enables Express Setup mode on the switch. show setup express Displays if Express Setup mode is active on the switch. Catalyst 3550 Multilayer Switch Command Reference 2-43 78-11195-09...
  • Page 70: Clear Spanning-Tree Counters

    12.1(13)EA1 This command was first introduced. Examples This example shows how to clear spanning-tree counters for all interfaces: Switch# clear spanning-tree counters Related Commands Command Description show spanning-tree Displays spanning-tree state information. Catalyst 3550 Multilayer Switch Command Reference 2-44 78-11195-09...
  • Page 71: Clear Spanning-Tree Detected-Protocols

    Use the clear spanning-tree detected-protocols command in this situation. Examples This example shows how to restart the protocol migration process on Fast Ethernet interface 0/1: Switch# clear spanning-tree detected-protocols interface fastethernet0/1 Catalyst 3550 Multilayer Switch Command Reference 2-45 78-11195-09...
  • Page 72: Clear Vmps Statistics

    You can verify that information was deleted by entering the show vmps statistics privileged EXEC command. Related Commands Command Description show vmps Displays the VQP version, reconfirmation interval, retry count, VMPS IP addresses, and the current and primary servers. Catalyst 3550 Multilayer Switch Command Reference 2-46 78-11195-09...
  • Page 73: Clear Vtp Counters

    You can verify that information was deleted by entering the show vtp counters privileged EXEC command. Related Commands Command Description show vtp Displays general information about the VTP management domain, status, and counters. Catalyst 3550 Multilayer Switch Command Reference 2-47 78-11195-09...
  • Page 74: Cluster Commander-Address

    When a standby command switch becomes active (becomes the command switch), it removes the cluster commander address line from its configuration. Catalyst 3550 Multilayer Switch Command Reference 2-48 78-11195-09...
  • Page 75 You can verify your settings by entering the show cluster privileged EXEC command. Related Commands Command Description show cluster Displays the cluster status and a summary of the cluster to which the switch belongs. Catalyst 3550 Multilayer Switch Command Reference 2-49 78-11195-09...
  • Page 76: Cluster Discovery Hop-Count

    You can verify your setting by entering the show cluster privileged EXEC command. Related Commands Command Description show cluster Displays the cluster status and a summary of the cluster to which the switch belongs. show cluster candidates Displays a list of candidate switches. Catalyst 3550 Multilayer Switch Command Reference 2-50 78-11195-09...
  • Page 77: Cluster Enable

    This example shows how to enable the command switch, name the cluster, and set the command switch member number to 4. Switch(config)# cluster enable Engineering-IDF4 4 You can verify your setting by entering the show cluster privileged EXEC command on the command switch. Catalyst 3550 Multilayer Switch Command Reference 2-51 78-11195-09...
  • Page 78 Chapter 2 Cisco IOS Commands cluster enable Related Commands Command Description show cluster Displays the cluster status and a summary of the cluster to which the switch belongs. Catalyst 3550 Multilayer Switch Command Reference 2-52 78-11195-09...
  • Page 79: Cluster Holdtime

    You can verify your settings by entering the show cluster privileged EXEC command. Related Commands Command Description show cluster Displays the cluster status and a summary of the cluster to which the switch belongs. Catalyst 3550 Multilayer Switch Command Reference 2-53 78-11195-09...
  • Page 80: Cluster Member

    If you do not specify a VLAN ID, the command switch automatically chooses a VLAN and adds the candidate to the cluster. Catalyst 3550 Multilayer Switch Command Reference 2-54 78-11195-09...
  • Page 81 Displays the cluster status and a summary of the cluster to which the switch belongs. show cluster candidates Displays a list of candidate switches. show cluster members Displays information about the cluster members. Catalyst 3550 Multilayer Switch Command Reference 2-55 78-11195-09...
  • Page 82: Cluster Outside-Interface

    Description show running-config Displays the current operating configuration. For syntax information, select the Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-56 78-11195-09...
  • Page 83: Cluster Run

    You can verify your setting by entering the show cluster privileged EXEC command. Related Commands Command Description show cluster Displays the cluster status and a summary of the cluster to which the switch belongs. Catalyst 3550 Multilayer Switch Command Reference 2-57 78-11195-09...
  • Page 84: Cluster Standby-Group

    Switch(config)# cluster standby-group my_hsrp This example shows how to use the same HSRP group named my_hsrp for routing redundancy and cluster redundancy. Switch(config)# cluster standby-group my_hsrp routing-redundancy Catalyst 3550 Multilayer Switch Command Reference 2-58 78-11195-09...
  • Page 85 Related Commands Command Description standby ip Enables HSRP on the interface. For syntax information, select Cisco IOS IP and IP Routing Command Reference for IOS Release 12.1 > IP Addressing and Services > IP Services Commands. show cluster Displays the cluster status and a summary of the cluster to which the switch belongs.
  • Page 86: Cluster Timer

    You can verify your settings by entering the show cluster privileged EXEC command. Related Commands Command Description show cluster Displays the cluster status and a summary of the cluster to which the switch belongs. Catalyst 3550 Multilayer Switch Command Reference 2-60 78-11195-09...
  • Page 87: Define Interface-Range

    VLAN interfaces must have been configured with the interface vlan command (the show running-config privileged EXEC command displays the configured VLAN interfaces). VLAN interfaces not displayed by the show running-config command cannot be used in interface-ranges. Catalyst 3550 Multilayer Switch Command Reference 2-61 78-11195-09...
  • Page 88 For physical interfaces, the interface-id is defined as slot/number (where slot is always 0 for the Catalyst 3550 switch), and the range can be entered as one of the following: • type 0/number - number (for example, gigabitethernet0/1 -2) •...
  • Page 89: Delete

    The prompting behavior depends on the setting of the file prompt global configuration command. By default, the switch prompts for confirmation on destructive file operations. For more information about this command, refer to the Cisco IOS Command Reference for Release 12.1. Examples...
  • Page 90: Deny

    (Optional) Select EtherType Digital Equipment Corporation (DEC) spanning tree. decnet-iv (Optional) Select EtherType DECnet Phase IV protocol. diagnostic (Optional) Select EtherType DEC-Diagnostic. (Optional) Select EtherType DEC-DSM. etype-6000 (Optional) Select EtherType 0x6000. etype-8042 (Optional) Select EtherType 0x8042. Catalyst 3550 Multilayer Switch Command Reference 2-64 78-11195-09...
  • Page 91 To filter IPX traffic, you use the type mask or lsap lsap mask keywords, depending on the type of IPX encapsulation being used. Filter criteria for IPX encapsulation types as specified in Novell terminology and Cisco IOS terminology are listed in Table 2-3.
  • Page 92 Creates an access list based on MAC addresses for non-IP traffic. permit Permits non-IP traffic to be forwarded if conditions are matched. show access-lists Displays access control lists configured on a switch. Catalyst 3550 Multilayer Switch Command Reference 2-66 78-11195-09...
  • Page 93: Dot1X Default

    Switch(config-if)# dot1x default You can verify your settings by entering the show dot1x [interface interface-id] privileged EXEC command. Related Commands Command Description show dot1x [interface Displays 802.1X status for the specified interface. interface-id] Catalyst 3550 Multilayer Switch Command Reference 2-67 78-11195-09...
  • Page 94: Dot1X Guest-Vlan

    Switch(config-if)# dot1x guest-vlan 5 You can verify your settings by entering the show dot1x [interface interface-id] privileged EXEC command. Related Commands Command Description show dot1x [interface Displays 802.1X status for the specified interface. interface-id] Catalyst 3550 Multilayer Switch Command Reference 2-68 78-11195-09...
  • Page 95: Dot1X Host-Mode

    Switch(config)# dot1x system-auth-control Switch(config)# interface fastethernet0/1 Switch(config-if)# dot1x port-control auto Switch(config-if)# dot1x host-mode multi-host You can verify your settings by entering the show dot1x [interface interface-id] privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-69 78-11195-09...
  • Page 96 Chapter 2 Cisco IOS Commands dot1x host-mode Related Commands Command Description show dot1x [interface Displays 802.1X status for the specified interface. interface-id] Catalyst 3550 Multilayer Switch Command Reference 2-70 78-11195-09...
  • Page 97: Dot1X Initialize

    Switch# dot1x initialize interface fastethernet0/1 You can verify your settings by entering the show dot1x [interface interface-id] privileged EXEC command. Related Commands Command Description show dot1x [interface Displays 802.1X status for the specified interface. interface-id] Catalyst 3550 Multilayer Switch Command Reference 2-71 78-11195-09...
  • Page 98: Dot1X Max-Req

    Sets the number of seconds that the switch waits for a response to an EAP-request/identity frame from the client before resending the request. show dot1x [interface Displays 802.1X status for the specified interface. interface-id] Catalyst 3550 Multilayer Switch Command Reference 2-72 78-11195-09...
  • Page 99: Dot1X Multiple-Hosts

    Related Commands Command Description dot1x host-mode Set the 802.1X host mode on an interface. show dot1x Displays 802.1X statistics, administrative status, and operational status for the switch or for the specified interface. Catalyst 3550 Multilayer Switch Command Reference 2-73 78-11195-09...
  • Page 100: Dot1X Port-Control

    [VQP]) port, an error message appears, and 802.1X is not enabled. If you try to change an 802.1X-enabled port to dynamic VLAN assignment, an error message appears, and the VLAN configuration is not changed. Catalyst 3550 Multilayer Switch Command Reference 2-74 78-11195-09...
  • Page 101 Switch(config-if)# dot1x port-control auto You can verify your settings by entering the show dot1x [interface interface-id] privileged EXEC command. Related Commands Command Description show dot1x [interface Displays 802.1X status for the specified interface. interface-id] Catalyst 3550 Multilayer Switch Command Reference 2-75 78-11195-09...
  • Page 102: Dot1X Re-Authenticate

    This example shows how to manually re-authenticate the device connected to Fast Ethernet interface 0/1: Switch# dot1x re-authenticate interface fastethernet0/1 Related Commands Command Description show dot1x Displays 802.1X statistics, administrative status, and operational status for the switch or for the specified interface. Catalyst 3550 Multilayer Switch Command Reference 2-76 78-11195-09...
  • Page 103: Dot1X Re-Authentication

    Related Commands Command Description dot1x reauthentication Sets the number of seconds between re-authentication attempts. show dot1x Displays 802.1X statistics, administrative status, and operational status for the switch or for the specified interface. Catalyst 3550 Multilayer Switch Command Reference 2-77 78-11195-09...
  • Page 104: Dot1X Re-Authentication

    This example shows how to enable periodic re-authentication and to set the number of seconds between re-authentication attempts to 4000 seconds: Switch(config-if)# dot1x reauthentication Switch(config-if)# dot1x timeout reauth-period 4000 You can verify your settings by entering the show dot1x [interface interface-id] privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-78 78-11195-09...
  • Page 105: Dot1X Reauthentication

    Chapter 2 Cisco IOS Commands dot1x reauthentication Related Commands Command Description dot1x timeout Sets the number of seconds between re-authentication attempts. show dot1x [interface Displays 802.1X status for the specified interface. interface-id] Catalyst 3550 Multilayer Switch Command Reference 2-79 78-11195-09...
  • Page 106: Dot1X System-Auth-Control

    You can verify your settings by entering the show dot1x privileged EXEC command. Related Commands Command Description show dot1x Displays 802.1X statistics, administrative status, and operational status for the switch or for the specified interface. Catalyst 3550 Multilayer Switch Command Reference 2-80 78-11195-09...
  • Page 107: Dot1X Timeout

    The dot1x timeout reauth-period interface configuration command affects the behavior of the switch only if you have enabled periodic re-authentication by using the dot1x reauthentication interface configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-81 78-11195-09...
  • Page 108 Sets the maximum number of times that the switch sends an EAP-request/identity frame before restarting the authentication process. dot1x reauthentication Enables periodic re-authentication of the client. show dot1x [interface Displays 802.1X status for the specified interface. interface-id] Catalyst 3550 Multilayer Switch Command Reference 2-82 78-11195-09...
  • Page 109: Duplex

    The duplex setting remains as configured on each end of the link, which could result in a duplex setting mismatch. If both the speed and duplex are set to specific values, autonegotiation is disabled. Catalyst 3550 Multilayer Switch Command Reference 2-83 78-11195-09...
  • Page 110 You can verify your setting by entering the show interfaces privileged EXEC command. Related Commands Command Description show interfaces Displays the interface settings on the switch. speed Sets the speed on a 10/100/1000 Mbps interface. Catalyst 3550 Multilayer Switch Command Reference 2-84 78-11195-09...
  • Page 111: Errdisable Detect Cause

    A cause (dhcp-rate-limit, dtp-flap, gbic-invalid, l2ptguard, link-flap, loopback, and pagp-flap) is defined as the reason why the error-disabled state occurred. When a cause is detected on an interface, the interface is placed in error-disabled state, an operational state similar to link-down state. Catalyst 3550 Multilayer Switch Command Reference 2-85 78-11195-09...
  • Page 112 You can verify your setting by entering the show errdisable detect privileged EXEC command. Related Commands Command Description show errdisable detect Displays errdisable detection information. show interfaces status err-disabled Displays interface status or a list of interfaces in the error-disabled state. Catalyst 3550 Multilayer Switch Command Reference 2-86 78-11195-09...
  • Page 113: Errdisable Recovery

    The difference between the actual timeout value and the configured value can be up to 15 percent of the configured interval. Defaults Recovery is disabled for all causes. The default recovery interval is 300 seconds. Catalyst 3550 Multilayer Switch Command Reference 2-87 78-11195-09...
  • Page 114 You can verify your settings by entering the show errdisable recovery privileged EXEC command. Related Commands Command Description show errdisable recovery Displays errdisable recovery timer information. show interfaces status Displays interface status or a list of interfaces in error-disabled err-disabled state. Catalyst 3550 Multilayer Switch Command Reference 2-88 78-11195-09...
  • Page 115: Flowcontrol

    Use the receive off and send off keywords to disable flow control. flowcontrol {receive | send} {desired | off | on} On Catalyst 3550 switches, Gigabit Ethernet ports can receive and send pause frames; Fast Ethernet ports Note can receive only pause frames. Therefore, for 10/100 ports, the send keyword is not available.
  • Page 116 QoS on the switch. Note that when used with receive, the on and desired keywords have the same result. On Catalyst 3550 switches, 10/100/1000 Mbps and GBIC ports and can receive and send pause frames; Note 10/100 Mbps ports can receive only pause frames. Therefore, for 10/100 ports, the conditions described in the next paragraphs are always send off.
  • Page 117 You can verify your settings by entering the show interfaces privileged EXEC command. Related Commands Command Description show interfaces Displays the interface settings on the switch, including input and output flow control. Catalyst 3550 Multilayer Switch Command Reference 2-91 78-11195-09...
  • Page 118: Interface Port-Channel

    If you configure Inter-Switch Link (ISL), you must assign the IP address to the switch virtual • interface (SVI). • If you want to use the CDP, you must configure it only on the physical interface and not on the port-channel interface. Catalyst 3550 Multilayer Switch Command Reference 2-92 78-11195-09...
  • Page 119 Displays EtherChannel information for a channel. show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-93...
  • Page 120: Interface Range

    You can define up to five interface ranges with a single command, with each range separated by a comma. All interfaces in a range must be the same type; that is, all Fast Ethernet ports, all Gigabit Ethernet ports, all EtherChannel ports, or all VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-94 78-11195-09...
  • Page 121 • For physical interfaces, the interface-id is defined as a slot/number (where slot is always 0 for the Catalyst 3550 switch), and you can enter the range in one of these ways: type 0/number - number (for example, gigabitethernet0/1 -2) •...
  • Page 122: Interface Vlan

    For the Catalyst 3550 Gigabit Ethernet switches, the tables are based on 16 routed interfaces (SVIs and routed ports. For switches with mainly Fast Ethernet ports, the tables are based on 8 routed interfaces. For more...
  • Page 123 You can verify your setting by entering the show interfaces and show interfaces vlan vlan-id privileged EXEC commands. Related Commands Command Description show interfaces vlan vlan-id Displays the administrative and operational status of all interfaces or the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-97 78-11195-09...
  • Page 124: Ip Access-Group

    You can apply IP ACLs to both outbound or inbound Layer 3 interfaces. A Layer 2 interface can have only one IP ACL applied (in the inbound direction). A Layer 3 interface can have one IP ACL applied in each direction. Catalyst 3550 Multilayer Switch Command Reference 2-98 78-11195-09...
  • Page 125 Release 12.1 > IP Addressing and Services > IP Services Commands. ip access-list Configures a named ACL. For syntax information, select Cisco IOS IP and IP Routing Command Reference for IOS Release 12.1 > IP Addressing and Services > IP Services Commands.
  • Page 126: Ip Address

    When you are routing Open Shortest Path First (OSPF), ensure that all secondary addresses of an interface fall into the same OSPF area as the primary addresses. Catalyst 3550 Multilayer Switch Command Reference 2-100 78-11195-09...
  • Page 127 You can use the sdm prefer global configuration command to reallocate system hardware resources based on templates and feature tables. For the Catalyst 3550 Gigabit Ethernet switches, the tables are based on 16 routed interfaces (SVIs and routed ports. For switches with mainly Fast Ethernet ports, the tables are based on 8 routed interfaces.
  • Page 128: Ip Dhcp Snooping

    The previous version uses the snmp-ifindex circuit ID and remote ID suboption. If you have option 82 configured on the switch and you upgrade to Cisco IOS Release 12.1(19)EA1 or later, the option-82 configuration is not affected. However, when you enable DHCP snooping globally on the switch by using the ip dhcp snooping global configuration command, the previous option-82 configuration is suspended, and the new option-82 format is applied.
  • Page 129 Command Description ip dhcp snooping vlan Enables DHCP snooping on a VLAN. show ip dhcp snooping Displays the DHCP snooping configuration. show ip dhcp snooping binding Displays the DHCP snooping binding information. Catalyst 3550 Multilayer Switch Command Reference 2-103 78-11195-09...
  • Page 130: Ip Dhcp Snooping Information Option

    The switch removes the option-82 field and forwards the packet to the switch port that connects to the DHCP host that sent the DHCP request. In Cisco IOS Release 12.1(19)EA1, the implementation for the option-82 subscriber identification changed from the previous release. The new option-82 format uses a different circuit ID and remote ID suboption, vlan-mod-port.
  • Page 131 You can verify your settings by entering the show ip dhcp snooping privileged EXEC command. Related Commands Command Description show ip dhcp snooping Displays the DHCP snooping configuration. show ip dhcp snooping binding Displays the DHCP snooping binding information. Catalyst 3550 Multilayer Switch Command Reference 2-105 78-11195-09...
  • Page 132: Ip Dhcp Snooping Information Option Format Snmp-Ifindex

    This command was first introduced. Usage Guidelines If you have option 82 configured on the switch and you upgrade to Cisco IOS Release 12.1(19)EA1 or later, the option 82 configuration is not affected. However, when you enable Dynamic Host Configuration Protocol (DHCP) snooping globally on the switch by using the ip dhcp snooping global configuration command, the relay agent information option configuration is disabled.
  • Page 133: Ip Dhcp Snooping Limit Rate

    You can verify your settings by entering the show ip dhcp snooping privileged EXEC command. Related Commands Command Description errdisable recovery Configures the recover mechanism. show ip dhcp snooping Displays the DHCP snooping configuration. show ip dhcp snooping binding Displays the DHCP snooping binding information. Catalyst 3550 Multilayer Switch Command Reference 2-107 78-11195-09...
  • Page 134: Ip Dhcp Snooping Trust

    You can verify your settings by entering the show ip dhcp snooping privileged EXEC command. Related Commands Command Description show ip dhcp snooping Displays the DHCP snooping configuration. show ip dhcp snooping binding Displays the DHCP snooping binding information. Catalyst 3550 Multilayer Switch Command Reference 2-108 78-11195-09...
  • Page 135: Ip Dhcp Snooping Vlan

    You can verify your settings by entering the show ip dhcp snooping privileged EXEC command. Related Commands Command Description show ip dhcp snooping Displays the DHCP snooping configuration. show ip dhcp snooping binding Displays the DHCP snooping binding information. Catalyst 3550 Multilayer Switch Command Reference 2-109 78-11195-09...
  • Page 136: Ip Igmp Filter

    You can verify your setting by using the show running-config privileged EXEC command and by specifying an interface. Switch# show running-config interface fastethernet0/12 Building configuration... Current configuration : 124 bytes interface FastEthernet0/12 no ip address shutdown snmp trap link-status ip igmp filter 22 Catalyst 3550 Multilayer Switch Command Reference 2-110 78-11195-09...
  • Page 137 (if any) that is applied to an interface. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-111...
  • Page 138: Ip Igmp Max-Groups

    If you configure the throttling action as replace and set the maximum group limitation, the entries • that were previously in the forwarding table are removed. When the maximum number of entries is Catalyst 3550 Multilayer Switch Command Reference 2-112 78-11195-09...
  • Page 139 Displays the running configuration on the switch interface, including interface-id the maximum number of IGMP groups that an interface can join and the throttling action. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands.
  • Page 140: Ip Igmp Profile

    This example shows how to configure IGMP profile 40 that permits the specified range of IP multicast addresses. Switch # config terminal Switch(config)# ip igmp profile 40 Switch(config-igmp-profile)# permit Switch(config-igmp-profile)# range 233.1.1.1 233.255.255.255 You can verify your settings by using the show ip igmp profile privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-114 78-11195-09...
  • Page 141 Related Commands Command Description ip igmp filter Applies the IGMP profile to the specified interface. show ip igmp profile Displays the characteristics of all IGMP profiles or the specified IGMP profile number. Catalyst 3550 Multilayer Switch Command Reference 2-115 78-11195-09...
  • Page 142: Ip Igmp Snooping

    (Optional) Add a Layer 2 port as a member of a multicast group with the specified group MAC address. Note Though visible in the command-line help string, the tcn keyword is not supported. Catalyst 3550 Multilayer Switch Command Reference 2-116 78-11195-09...
  • Page 143 This example shows how to enable IGMP immediate-leave processing on VLAN 1: Switch(config)# ip igmp snooping vlan 1 immediate-leave This example shows how to disable IGMP immediate-leave processing on VLAN 1: Switch(config)# no ip igmp snooping vlan 1 immediate-leave Catalyst 3550 Multilayer Switch Command Reference 2-117 78-11195-09...
  • Page 144 Displays the snooping configuration. show mac address-table multicast Displays the Layer 2 multicast entries for a VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-118 78-11195-09...
  • Page 145: Ip Igmp Snooping Report-Suppression

    Switch(config)# no ip igmp snooping report-suppression This example shows how to enable report suppression: Switch(config)# ip igmp snooping report-suppression You can verify your settings by entering the show ip igmp snooping privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-119 78-11195-09...
  • Page 146 Globally enables IGMP snooping. IGMP snooping must be globally enabled in order to be enabled on a VLAN. show ip igmp snooping Displays the IGMP snooping configuration of the switch or the VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-120 78-11195-09...
  • Page 147: Ip Igmp Snooping Source-Only-Learning Age-Timer

    This example shows how to set the aging time as 1200 seconds (20 minutes): Switch(config)# ip igmp snooping source-only-learning age-timer 1200 This example shows how to disable aging of the forward-table entries: Switch(config)# ip igmp snooping source-only-learning age-timer 0 Catalyst 3550 Multilayer Switch Command Reference 2-121 78-11195-09...
  • Page 148 | include Displays the configuration information running on the switch. For source-only-learning syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 149: Ip Ssh

    This example shows how to configure the switch to run SSH version 2: Switch(config)# ip ssh version 2 You can verify your settings by entering the show ip ssh or show ssh privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-123 78-11195-09...
  • Page 150 References > Cisco IOS Security Command Reference, Release 12.2 > Other Security Features > Secure Shell Commands. show ssh Displays the status of the SSH server. For syntax information, select Cisco IOS Release 12.2 Configuration Guides and Command References > Cisco IOS Security Command Reference, Release 12.2 > Other Security Features >...
  • Page 151: Ip Vrf (Global Configuration)

    VRF routing table and to return to global configuration mode. ip vrf vrf-name no ip vrf vrf-name The Catalyst 3550 switch supports multi-VPN routing/forwarding (multi-VRF) instances in customer Note edge (CE) devices. You must have the enhanced multilayer image (EMI) installed on your switch to configure multi-VRF CE.
  • Page 152: Ip Vrf (Global Configuration)

    IP address and an arbitrary number. The ip vrf vrf-name command creates a VRF routing table and a Cisco Express Forwarding (CEF) forwarding table, both named vrf-name. Associated with these tables is the default route distinguisher value route-distinguisher.
  • Page 153: Ip Vrf (Interface Configuration)

    {forwarding table-name | sitemap route-map-name} no ip vrf {forwarding table-name | sitemap route-map-name} The Catalyst 3550 switch supports multi-VPN routing/forwarding (multi-VRF) instances in customer Note edge (CE) devices. You must have the enhanced multilayer image (EMI) installed on your switch to configure multi-VRF CE.
  • Page 154: Ip Vrf (Interface Configuration)

    Configures a VRF routing table. ip route vrf Establishes static routes for a VRF. For syntax information, go to Cisco IOS Switching Services Command Reference for Release 12.1. show ip route vrf Displays the IP routing table associated with a VRF. For syntax information, go to Cisco IOS Switching Services Command Reference for Release 12.1.
  • Page 155: L2Protocol-Tunnel

    Use the l2protocol-tunnel interface configuration command to enable tunneling of Layer 2 protocols on an access or 802.1Q tunnel port. You can enable tunneling for Cisco Discovery Protocol (CDP), Spanning Tree Protocol (STP), or VLAN Trunking Protocol (VTP) packets. You can also enable point-to-point tunneling for Port Aggregation Protocol (PAgP), Link Aggregation Control Protocol (LACP), or UniDirectional Link Detection (UDLD) packets.
  • Page 156 When protocol tunneling is enabled, protocol packets are encapsulated with a well-known Cisco multicast address for transmission across the network. When the packets reach their destination, the well-known MAC address is replaced by the Layer 2 protocol MAC address.
  • Page 157 Configures a class of service (CoS) value for all tunneled Layer 2 protocol packets. show errdisable recovery Displays errdisable recovery timer information. show l2protocol-tunnel Displays information about ports configured for Layer 2 protocol tunneling, including port, protocol, class of service (CoS), and threshold. Catalyst 3550 Multilayer Switch Command Reference 2-131 78-11195-09...
  • Page 158: L2Protocol-Tunnel Cos

    This example shows how to configure a Layer-2 protocol-tunnel CoS value of 7: Switch(config)# l2protocol-tunnel cos 7 Related Commands Command Description show l2protocol-tunnel Displays information about ports configured for Layer 2 protocol tunneling, including CoS. Catalyst 3550 Multilayer Switch Command Reference 2-132 78-11195-09...
  • Page 159: Lacp Port-Priority

    This example shows set the port priority for LACP: Switch(config)# lacp port-priority 32764 You can verify your settings by entering the show etherchannel privileged EXEC command. Related Commands Command Description lacp system-priority Globally sets the LACP priority. Catalyst 3550 Multilayer Switch Command Reference 2-133 78-11195-09...
  • Page 160: Lacp System-Priority

    Switch(config)# lacp system-priority 32764 You can verify your settings by entering the show lacp internal privileged EXEC command. Related Commands Command Description lacp port-priority Sets the LACP priority for a specific port. Catalyst 3550 Multilayer Switch Command Reference 2-134 78-11195-09...
  • Page 161: Logging File

    The command rejects the minimum file size if it is greater than the maximum file size minus 1024; the minimum file size then becomes the maximum file size minus 1024. Specifying a level causes messages at that level and numerically lower levels to be displayed. Catalyst 3550 Multilayer Switch Command Reference 2-135 78-11195-09...
  • Page 162 Description show running-config Displays the running configuration on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-136...
  • Page 163: Mac Access-Group

    If the specified ACL does not exist, the switch forwards all packets. For more information about configuring MAC extended ACLs, refer to the “Configuring Network Note Security with ACLs” chapter in the software configuration guide for this release. Catalyst 3550 Multilayer Switch Command Reference 2-137 78-11195-09...
  • Page 164 Displays the MAC ACLs configured on the switch. show running-config Displays the running configuration on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-138...
  • Page 165: Mac Access-List Extended

    • permit: specifies packets to forward. For more information, see the permit command. • For more information about MAC extended access lists, refer to the software configuration guide for this Note release. Catalyst 3550 Multilayer Switch Command Reference 2-139 78-11195-09...
  • Page 166 Displays the access lists configured on the switch. vlan access-map Defines a VLAN map and enters access-map configuration mode where you can specify a MAC ACL to match and the action to be taken. Catalyst 3550 Multilayer Switch Command Reference 2-140 78-11195-09...
  • Page 167: Mac Address-Table Aging-Time

    The aging time applies to all VLANs or a specified VLAN. mac address-table aging-time {0 | 10-1000000} [vlan vlan-id] no mac address-table aging-time {0 | 10-1000000} [vlan vlan-id] Beginning with Cisco IOS Release 12.1(11)EA1, the mac address-table aging-time command replaces Note the mac-address-table aging-time command (with the hyphen).
  • Page 168 Chapter 2 Cisco IOS Commands mac address-table aging-time Related Commands Command Description show mac address-table aging-time Displays the MAC address table aging time for all VLANs or the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-142 78-11195-09...
  • Page 169: Mac Address-Table Notification

    Use the no form of this command to return to the default setting. mac address-table notification [history-size value] | [interval value] no mac address-table notification [history-size | interval] Beginning with Cisco IOS Release 12.1(11)EA1, the mac address-table notification command replaces Note the mac-address-table notification command (with the hyphen).
  • Page 170 Sends the SNMP MAC notification traps when the mac-notification keyword is appended. snmp trap mac-notification Enables the SNMP MAC notification trap on a specific interface. Catalyst 3550 Multilayer Switch Command Reference 2-144 78-11195-09...
  • Page 171: Mac Address-Table Static

    Use the no form of this command to remove static entries from the table. mac address-table static mac-addr vlan vlan-id interface interface-id no mac address-table static mac-addr vlan vlan-id [interface interface-id] Beginning with Cisco IOS Release 12.1(11)EA1, the mac address-table static command replaces the Note mac-address-table static command (with the hyphen).
  • Page 172: Mac Address-Table Static Drop

    If you enter the mac address-table static mac-addr vlan vlan-id drop global configuration command followed by the mac address-table static mac-addr vlan vlan-id interface interface-id command, the switch adds the MAC address as a static address. Catalyst 3550 Multilayer Switch Command Reference 2-146 78-11195-09...
  • Page 173: Mac Address-Table Static Drop

    Switch(config)# no mac address-table static c2f3.220a.12f4 vlan 4 You can verify your setting by entering the show mac address-table static privileged EXEC command. Related Commands Command Description show mac address-table static Displays only static MAC address table entries. Catalyst 3550 Multilayer Switch Command Reference 2-147 78-11195-09...
  • Page 174: Macro Apply

    This example shows how to apply the duplex macro to an interface: Switch(config-if)#macro apply duplex This example shows how troubleshoot a macro on an interface: Switch(config-if)# macro trace duplex2 Applying command...‘duplex auto’ %Error Unknown error. Applying command...‘speed nonegotiate’ Catalyst 3550 Multilayer Switch Command Reference 2-148 78-11195-09...
  • Page 175 Displays the configuration information currently running on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 176: Macro Description

    Displays the configuration information currently running on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 177: Macro Name

    This example shows how to create a macro that defines the duplex mode and speed: Switch(config)# macro name duplex Enter macro commands one per line. End with the character ‘@’. duplex full speed auto Catalyst 3550 Multilayer Switch Command Reference 2-151 78-11195-09...
  • Page 178 Displays the current operating configuration, including defined macros. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-152...
  • Page 179: Match (Access-Map Configuration)

    Packets are matched only against access lists of the same protocol type; IP packets are matched against IP access lists, and all other packets are matched against MAC access lists. Both IP and MAC addresses can be specified for the same map entry. Catalyst 3550 Multilayer Switch Command Reference 2-153 78-11195-09...
  • Page 180: Match (Access-Map Configuration)

    Specifies the action to be taken if the packet matches an entry in an access control list (ACL). ip access list Creates a named access list. For syntax information, select Cisco IOS IP and IP Routing Command Reference for IOS Release 12.1 > IP Addressing and Services > IP Services Commands.
  • Page 181: Match (Class-Map Configuration)

    Defaults No match criteria are defined. Command Modes Class-map configuration Command History Release Modification 12.1(4)EA1 This command was first introduced. 12.1(11)EA1 The class-map and vlan keywords were added. Catalyst 3550 Multilayer Switch Command Reference 2-155 78-11195-09...
  • Page 182: Match (Class-Map Configuration)

    Access control list (ACL) classification. Per-port per-VLAN classification. • The only match criterion in a policy map that can be attached to an egress interface is the match ip dscp dscp-list class-map configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-156 78-11195-09...
  • Page 183 You can verify your settings by entering the show class-map privileged EXEC command. Related Commands Command Description class-map Creates a class map to be used for matching packets to the class whose name you specify. show class-map Displays quality of service (QoS) class maps. Catalyst 3550 Multilayer Switch Command Reference 2-157 78-11195-09...
  • Page 184: Mls Aclmerge Delay

    This example shows how to change the merge delay to be 2000 milliseconds (2 seconds): Switch(config)# mls aclmerge delay 2000 This example shows how to set the merge to be performed immediately: Switch(config)# mls aclmerge delay 0 Catalyst 3550 Multilayer Switch Command Reference 2-158 78-11195-09...
  • Page 185 Applies an IP access list to a Layer 2 or Layer 3 interface. ip access-list Configures a named access list. For syntax information, select Cisco IOS IP and IP Routing Command Reference for IOS Release 12.1 > IP Addressing and Services > IP Services Commands.
  • Page 186: Mls Qos

    When QoS is disabled, there is no concept of trusted or untrusted ports because the packets are not modified (the CoS, DSCP, and IP precedence values in the packet are not changed). Catalyst 3550 Multilayer Switch Command Reference 2-160 78-11195-09...
  • Page 187 Policy-maps and class-maps used to configure QoS are not deleted from the configuration by the no mls qos command, but entries corresponding to policy maps are removed from the switch hardware to save system resources. To re-enable QoS with the previous configurations, use the mls qos command. Catalyst 3550 Multilayer Switch Command Reference 2-161 78-11195-09...
  • Page 188 Assigns a minimum-reserve level to an egress queue on a 10/100 Ethernet port. wrr-queue queue-limit Configures the sizes of the egress queues on Gigabit-capable Ethernet ports. wrr-queue threshold Assigns tail-drop threshold percentages to an egress queue of a Gigabit-capable Ethernet port. Catalyst 3550 Multilayer Switch Command Reference 2-162 78-11195-09...
  • Page 189: Mls Qos Aggregate-Policer

    You apply an aggregate policer to multiple classes in the same policy map; you cannot use an aggregate policer across different policy maps or interfaces. Catalyst 3550 Multilayer Switch Command Reference 2-163 78-11195-09...
  • Page 190 You can verify your settings by entering the show mls qos aggregate-policer privileged EXEC command. Related Commands Command Description police aggregate Creates a policer that is shared by different classes. show mls qos aggregate-policer Displays the quality of service (QoS) aggregate policer configuration. Catalyst 3550 Multilayer Switch Command Reference 2-164 78-11195-09...
  • Page 191: Mls Qos Cos

    CoS value configured with the mls qos cos command. If an incoming packet is tagged, the CoS value of the packet is modified with the default CoS of the port at the ingress port. Catalyst 3550 Multilayer Switch Command Reference 2-165 78-11195-09...
  • Page 192 Switch(config-if)# mls qos cos override You can verify your settings by entering the show mls qos interface privileged EXEC command. Related Commands Command Description show mls qos interface Displays quality of service (QoS) information. Catalyst 3550 Multilayer Switch Command Reference 2-166 78-11195-09...
  • Page 193: Mls Qos Cos Policy-Map

    Switch(config)# mls qos cos policy-map Switch(config)# policy-map policy2 Switch(config-pmap)# class class1 Switch(config-pmap-c)# trust dscp Switch(config-pmap-c)# set cos 3 Switch(config-pmap-c)# exit You can verify your settings by entering the show policy-map privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-167 78-11195-09...
  • Page 194 Displays quality of service (QoS) policy maps. trust Defines a trust state for traffic classified by the class policy-map configuration or the class-map global configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-168 78-11195-09...
  • Page 195: Mls Qos Dscp-Mutation

    This example shows how to define the DSCP-to-DSCP-mutation map named dscpmutation1and to apply the map to a port: Switch(config)# mls qos map dscp-mutation dscpmutation1 10 11 12 13 to 30 Switch(config)# interface gigabitethernet0/1 Switch(config-if)# mls qos trust dscp Switch(config-if)# mls qos dscp-mutation dscpmutation1 Catalyst 3550 Multilayer Switch Command Reference 2-169 78-11195-09...
  • Page 196 You can verify your settings by entering the show mls qos maps privileged EXEC command. Related Commands Command Description mls qos map dscp-mutation Defines the DSCP-to-DSCP-mutation map. mls qos trust Configures the port trust state. show mls qos maps Displays QoS mapping information. Catalyst 3550 Multilayer Switch Command Reference 2-170 78-11195-09...
  • Page 197: Mls Qos Map

    For dscp-list, enter up to eight DSCP values, with each value separated by a space. Then enter the to keyword. For mark-down-dscp, enter the corresponding policed (marked down) DSCP value. The range is 0 to 63. Catalyst 3550 Multilayer Switch Command Reference 2-171 78-11195-09...
  • Page 198 10/100 Ethernet ports (Fast Ethernet 0/1 to 0/12, 0/13 to 0/24, and so forth) shares a single DSCP-to-DSCP-mutation map, only one map can be attached to each 10/100 group. Catalyst 3550 Multilayer Switch Command Reference 2-172 78-11195-09...
  • Page 199 You can verify your settings by entering the show mls qos maps privileged EXEC command. Related Commands Command Description mls qos dscp-mutation Applies a DSCP-to-DSCP-mutation map to a DSCP-trusted port. show mls qos maps Displays quality of service (QoS) mapping information. Catalyst 3550 Multilayer Switch Command Reference 2-173 78-11195-09...
  • Page 200: Mls Qos Min-Reserve

    You can verify your settings by entering the show mls qos interface buffers privileged EXEC command. Related Commands Command Description show mls qos interface Displays quality of service (QoS) information. wrr-queue min-reserve Assigns a minimum-reserve level to an egress queue on a 10/100 Ethernet port. Catalyst 3550 Multilayer Switch Command Reference 2-174 78-11195-09...
  • Page 201: Mls Qos Monitor

    Switch(config-if)# mls qos monitor dscp 10 11 12 13 Switch(config-if)# mls qos monitor packets You can see the results of the monitoring activity by entering the show mls qos interface statistics privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-175 78-11195-09...
  • Page 202 Displays all the DSCPs for which statistics are maintained and the corresponding ingress and egress statistics, including the number of bytes dropped, when the statistics keyword is appended. Catalyst 3550 Multilayer Switch Command Reference 2-176 78-11195-09...
  • Page 203: Mls Qos Trust

    (DSCP), class of service (CoS), or IP-precedence packet field. Use the no form of this command to return a port to its untrusted state. mls qos trust [cos [pass-through dscp] | device cisco-phone | dscp [pass-through cos] | ip-precedence] no mls qos trust [cos [pass-through] | device | dscp [pass-through] | ip-precedence] Syntax Description (Optional) Classify ingress packets with packet CoS values.
  • Page 204 The trusted boundary feature prevents security problems if users disconnect their PCs from networked Cisco IP phones and connect them to the switch port to take advantage of trusted CoS settings. You must globally enable the Cisco Discovery Protocol (CDP) on the switch and on the interface connected to the IP phone.
  • Page 205: Monitor Session

    Specify a list of VLANs as filters on trunk source ports. The vlan-id range is 1 to 4094. source interface Specify the SPAN source interface type, slot, and port number. Valid interface-id interfaces include physical ports and port channels. Catalyst 3550 Multilayer Switch Command Reference 2-179 78-11195-09...
  • Page 206 You can set a maximum of two SPAN or RSPAN sessions. You can divide the two sessions between SPAN, RSPAN source, and RSPAN destination sessions. Each session can have only one destination port and only one transmitting source port. You can, however, have multiple receiving source ports and VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-180 78-11195-09...
  • Page 207 If ingress forwarding is enabled, you can use the SPAN or RSPAN destination port to inject traffic from a network security device. For example, if you connect a Cisco Intrusion Detection System (IDS) Sensor Appliance to a destination port, the IDS device can send TCP Reset packets to close down the TCP session of a suspected attacker.
  • Page 208 You can verify your settings by entering the show monitor privileged EXEC command. Related Commands Command Description remote-span Configures an RSPAN VLAN in vlan configuration mode. show monitor Displays SPAN and RSPAN session information. Catalyst 3550 Multilayer Switch Command Reference 2-182 78-11195-09...
  • Page 209: Mvr (Global Configuration)

    No IP multicast addresses are configured on the switch by default. The default group ip address count is 0. The default query response time is 5 tenths of or one-half second. The default multicast VLAN for MVR is VLAN 1. Catalyst 3550 Multilayer Switch Command Reference 2-183 78-11195-09...
  • Page 210: Mvr (Global Configuration)

    Cannot add this IP address - aliases with previously configured IP address 228.1.23.4. This example shows how to configure ten contiguous IP multicast groups with multicast addresses from 228.1.23.1 to 228.1.23.10: Switch(config)# mvr group 228.1.23.1 10 Catalyst 3550 Multilayer Switch Command Reference 2-184 78-11195-09...
  • Page 211 Displays all ports that are members of an MVR multicast group; if the group has no members, its status is shown as Inactive. Catalyst 3550 Multilayer Switch Command Reference 2-185 78-11195-09...
  • Page 212: Mvr (Interface Configuration)

    The Immediate Leave feature is disabled on all ports. No receiver port is a member of any configured multicast group. Command Modes Interface configuration Command History Release Modification 12.1(4)EA1 This command was first introduced. Catalyst 3550 Multilayer Switch Command Reference 2-186 78-11195-09...
  • Page 213: Mvr (Interface Configuration)

    --------------- Gi0/1 SOURCE ACTIVE/UP DISABLED Gi0/2 RECEIVER ACTIVE/DOWN DISABLED Gi0/5 RECEIVER ACTIVE/UP ENABLED This example shows how to enable immediate leave on Gigabit Ethernet port 0/1: Switch(config)# interface gigabitethernet0/1 Switch(config-if)# mvr immediate Catalyst 3550 Multilayer Switch Command Reference 2-187 78-11195-09...
  • Page 214 Also displays all MVR groups of which the interface is a member. show mvr members Displays all receiver ports that are members of an MVR multicast group. Catalyst 3550 Multilayer Switch Command Reference 2-188 78-11195-09...
  • Page 215: Pagp Learn-Method

    Catalyst 1900 switch. When the link partner to the Catalyst 3550 switch is a physical learner, we recommend that you configure the switch as a physical-port learner by using the pagp learn-method physical-port interface configuration command and to set the load-distribution method based on the source MAC address by using the port-channel load-balance src-mac global configuration command.
  • Page 216 Displays PAgP channel-group information. show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-190...
  • Page 217: Pagp Port-Priority

    Catalyst 1900 switch. When the link partner to the Catalyst 3550 switch is a physical learner, we recommend that you configure the switch as a physical-port learner by using the pagp learn-method physical-port interface configuration command and to set the load-distribution method based on the source MAC address by using the port-channel load-balance src-mac global configuration command.
  • Page 218 Displays PAgP channel-group information. show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-192...
  • Page 219: Permit

    (Optional) Select EtherType Digital Equipment Corporation (DEC) spanning tree. decnet-iv (Optional) Select EtherType DECnet Phase IV protocol. diagnostic (Optional) Select EtherType DEC-Diagnostic. (Optional) Select EtherType DEC-DSM. etype-6000 (Optional) Select EtherType 0x6000. etype-8042 (Optional) Select EtherType 0x8042. Catalyst 3550 Multilayer Switch Command Reference 2-193 78-11195-09...
  • Page 220 To filter IPX traffic, you use the type mask or lsap lsap mask keywords, depending on the type of IPX encapsulation being used. Filter criteria for IPX encapsulation types as specified in Novell terminology and Cisco IOS terminology are listed in Table 2-11.
  • Page 221 Denies non-IP traffic to be forwarded if conditions are matched. mac access-list extended Creates an access list based on MAC addresses for non-IP traffic. show access-lists Displays access control lists configured on a switch. Catalyst 3550 Multilayer Switch Command Reference 2-195 78-11195-09...
  • Page 222: Police

    (the average rate) the tokens are removed from the bucket by using the rate-bps option of the police policy-map class configuration command or the mls qos aggregate-policer global configuration command. For more information, refer to the software configuration guide for this release. Catalyst 3550 Multilayer Switch Command Reference 2-196 78-11195-09...
  • Page 223 You can verify your settings by entering the show policy-map privileged EXEC command. Related Commands Command Description mls qos map policed-dscp Applies a policed-DSCP map to a DSCP-trusted port. show policy-map Displays quality of service (QoS) policy maps. Catalyst 3550 Multilayer Switch Command Reference 2-197 78-11195-09...
  • Page 224: Police Aggregate

    Policy maps that contain per-port per-VLAN classification commands cannot be applied to egress interfaces. To return to policy-map configuration mode, use the exit command. To return to privileged EXEC mode, use the end command. Catalyst 3550 Multilayer Switch Command Reference 2-198 78-11195-09...
  • Page 225 Command Description mls qos aggregate-policer Defines policer parameters, which can be shared by multiple classes within a policy map. show mls qos aggregate-policer Displays the quality of service (QoS) aggregate policer configuration. Catalyst 3550 Multilayer Switch Command Reference 2-199 78-11195-09...
  • Page 226: Policy-Map

    You use the class-map global configuration and match class-map configuration commands to configure the match criteria for a class. You define packet classification on a physical-port basis and on a per-port per-VLAN basis. Catalyst 3550 Multilayer Switch Command Reference 2-200 78-11195-09...
  • Page 227 Switch(config-pmap-c)# police 100000 20000 exceed-action policed-dscp-transmit Switch(config-pmap-c)# exit Switch(config-pmap)# class class2 Switch(config-pmap-c)# trust dscp Switch(config-pmap-c)# police 100000 20000 exceed-action drop Switch(config-pmap-c)# exit Switch(config-pmap)# class class3 Switch(config-pmap-c)# set dscp 0 (no policer) Switch(config-pmap-c)# exit Catalyst 3550 Multilayer Switch Command Reference 2-201 78-11195-09...
  • Page 228 Classifies IP traffic by setting a CoS, DSCP, or IP-precedence value in the packet. show policy-map Displays quality of service (QoS) policy maps. trust Defines a trust state for traffic classified by the class or the class-map command. Catalyst 3550 Multilayer Switch Command Reference 2-202 78-11195-09...
  • Page 229: Port-Channel Load-Balance

    Displays EtherChannel information for a channel. show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-203...
  • Page 230: Power Inline

    The delay shutdown seconds initial seconds keywords were added. Usage Guidelines When using a Cisco Power Device, the delay shutdown command is not needed. Although you can configure a delay shutdown time, it does not take any action on a connected Cisco device.
  • Page 231 You can verify your settings by entering the show running-config privileged EXEC command. Related Commands Command Description show power inline Displays the power status for the specified port or for all ports. Catalyst 3550 Multilayer Switch Command Reference 2-205 78-11195-09...
  • Page 232: Priority-Queue

    You can verify your settings by entering the show running-config privileged EXEC command. Related Commands Command Description show mls qos interface queueing Displays the queueing strategy (WRR, priority queueing), the weights corresponding to the queues, and the CoS-to-egress-queue map. Catalyst 3550 Multilayer Switch Command Reference 2-206 78-11195-09...
  • Page 233: Rcommand

    This command will not work if the vty lines of the command switch have access-class configurations. You are not prompted for a password because the member switches inherited the password of the command switch when they joined the cluster. Catalyst 3550 Multilayer Switch Command Reference 2-207 78-11195-09...
  • Page 234 3 until you enter the exit command or close the session. Switch# rcommand 3 Switch-3# show version Cisco Internet Operating System Software ... Switch-3# exit Switch# Related Commands Command Description show cluster members Displays information about the cluster members. Catalyst 3550 Multilayer Switch Command Reference 2-208 78-11195-09...
  • Page 235: Remote-Span

    Enables Switched Port Analyzer (SPAN) and RSPAN monitoring on a port and configures a port as a source or destination port. vlan (global Changes to config-vlan mode where you can configure VLANs 1 to 4094; do configuration) not enter leading zeros. Catalyst 3550 Multilayer Switch Command Reference 2-209 78-11195-09...
  • Page 236: Rmon Collection Stats

    Related Commands Command Description show rmon statistics Displays RMON statistics. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS System Management Commands > RMON Commands. Catalyst 3550 Multilayer Switch Command Reference 2-210 78-11195-09...
  • Page 237: Sdm Prefer

    The sdm prefer vlan command disables routing capability in the switch. Any routing configurations are rejected after the reload, and any previously configured routing options might be lost. Use the sdm prefer vlan command only on switches intended for Layer 2 switching with no routing. Catalyst 3550 Multilayer Switch Command Reference 2-211 78-11195-09...
  • Page 238 Multicast routes Routed interfaces (routed ports and SVIs) 16 Layer 2 VLANs 1. When the extended-match keyword is used with the indicated template. This keyword affects only the number of unicast routes allowed. Catalyst 3550 Multilayer Switch Command Reference 2-212 78-11195-09...
  • Page 239 You can verify your settings by entering the show sdm prefer privileged EXEC command. Related Commands Command Description show sdm prefer Displays the current SDM template in use or displays the templates that can be used, with approximate resource allocation per feature. Catalyst 3550 Multilayer Switch Command Reference 2-213 78-11195-09...
  • Page 240: Service Password-Recovery

    This command was first introduced. Usage Guidelines This command is valid only on Catalyst 3550 Fast Ethernet switches; it is not available for Gigabit Ethernet switches. As a system administrator, you can use the no service password-recovery command to disable some of the functionality of the password recovery feature by allowing an end user to reset a password only by agreeing to return to the default configuration.
  • Page 241 1 week, 6 days, 3 hours, 59 minutes System returned to ROM by power-on System image file is "flash:c3550--i9q3l2-mz.121-8EA1.bin" cisco WS-C3550-48 (PowerPC) processor with 65526K/8192K bytes of memory. Last reset from warm-reset Running Layer2 Switching Only Image Ethernet-controller 1 has 12 Fast Ethernet/IEEE 802.3 interfaces...
  • Page 242 Chapter 2 Cisco IOS Commands service password-recovery Related Commands Command Description show version Displays version information for the hardware and firmware. Catalyst 3550 Multilayer Switch Command Reference 2-216 78-11195-09...
  • Page 243: Service-Policy

    A classification that uses a port trust state (for example, mls qos trust [cos | dscp | ip-precedence] and classification that uses a policy map (for example, service-policy input policy-map-name) are mutually exclusive. The last setting configured overwrites the previous configuration. Catalyst 3550 Multilayer Switch Command Reference 2-217 78-11195-09...
  • Page 244 Related Commands Command Description policy-map Creates or modifies a policy map that can be attached to multiple interfaces to specify a service policy. show policy-map Displays quality of service (QoS) policy maps. Catalyst 3550 Multilayer Switch Command Reference 2-218 78-11195-09...
  • Page 245: Set

    Instead, you can use the police policy-map class configuration command to mark down (reduce) the DSCP value at the egress interface. • Access control list (ACL) classification. • Per-port per-VLAN classification. Catalyst 3550 Multilayer Switch Command Reference 2-219 78-11195-09...
  • Page 246 Displays quality of service (QoS) policy maps. trust Defines a trust state for traffic classified by the class policy-map configuration command or the class-map global configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-220 78-11195-09...
  • Page 247: Setup

    You can save the configuration in nonvolatile RAM (NVRAM), return to the setup program without saving, or return to the command-line prompt without saving the configuration. Catalyst 3550 Multilayer Switch Command Reference 2-221 78-11195-09...
  • Page 248 OK? Method Status Protocol Vlan1 172.20.135.202 YES NVRAM GigabitEthernet0/1 unassigned YES unset GigabitEthernet0/2 unassigned YES unset down GigabitEthernet0/3 unassigned YES unset administratively down down GigabitEthernet0/4 unassigned YES unset down GigabitEthernet0/5 unassigned YES NVRAM down Catalyst 3550 Multilayer Switch Command Reference 2-222 78-11195-09...
  • Page 249 [0] Go to the IOS command prompt without saving this config. [1] Return back to the setup without saving this config. [2] Save this configuration to nvram and exit. Enter your selection [2]: Catalyst 3550 Multilayer Switch Command Reference 2-223 78-11195-09...
  • Page 250 Displays the running configuration on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. show version Displays version information for the hardware and firmware.
  • Page 251: Setup Express

    IP address ends. The primary purpose of the no setup express command is to prevent someone from deleting the switch configuration by pressing the Mode button for 10 seconds. Catalyst 3550 Multilayer Switch Command Reference 2-225 78-11195-09...
  • Page 252 Express Setup mode is enabled on the switch. Related Commands Command Description clear setup express Exits Express Setup mode without saving the configuration. show setup express Displays if Express Setup mode is active on the switch. Catalyst 3550 Multilayer Switch Command Reference 2-226 78-11195-09...
  • Page 253: Show Access-Lists

    This command was first introduced. Usage Guidelines The Catalyst 3550 multilayer switch supports only IP standard and extended access lists. Therefore, the allowed numbers are only 1 to 199 and 1300 to 2699. Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
  • Page 254 Description access-list Configures a standard or extended numbered access list on the switch. For syntax information, select Cisco IOS IP and IP Routing Command Reference for IOS Release 12.1 > IP Addressing and Services > IP Services Commands. ip access list Configures a named IP access list on the switch.
  • Page 255: Show Auto Qos

    5 170 ! (only if 10/100 ports exist) mls qos min-reserve 6 10 ! (only if 10/100 ports exist) mls qos min-reserve 7 65 ! (only if 10/100 ports exist) Catalyst 3550 Multilayer Switch Command Reference 2-229 78-11195-09...
  • Page 256 4 5 priority-queue out This is an example of output from the show auto qos interface gigabitethernet0/3 command when the auto qos voip cisco-phone interface configuration command is entered: Switch# show auto qos interface gigabitethernet0/3 Initial configuration applied by AutoQoS:...
  • Page 257: Show Boot

    Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Only the Cisco IOS software can read and write a copy of the private configuration file. You cannot read, Note write, delete, or display a copy of this file.
  • Page 258 NVRAM/Config file buffer size Displays the buffer size that Cisco IOS uses to hold a copy of the configuration file in memory. The configuration file cannot be larger than the buffer size allocation.
  • Page 259: Show Class-Map

    Related Commands Command Description class-map Creates a class map to be used for matching packets to the class whose name you specify. match (class-map configuration) Defines the match criteria to classify traffic. Catalyst 3550 Multilayer Switch Command Reference 2-233 78-11195-09...
  • Page 260: Show Cluster

    Time since last status change: 0 days, 0 hours, 2 minutes Redundancy: Enabled Standby command switch: Member 1 Standby Group: Ajang_standby Standby Group Number: Heartbeat interval: Heartbeat hold-time: Extended discovery hop count: Catalyst 3550 Multilayer Switch Command Reference 2-234 78-11195-09...
  • Page 261 Enables a command-capable switch as the cluster command switch, assigns a cluster name, and optionally assigns a member number to it. show cluster candidates Displays a list of candidate switches. show cluster members Displays information about the cluster members. Catalyst 3550 Multilayer Switch Command Reference 2-235 78-11195-09...
  • Page 262: Show Cluster Candidates

    FEC Hops SN PortIf 00d0.7961.c4c0 StLouis-2 WS-C3550-12T Gi0/1 Fa0/11 00d0.bbf5.e900 ldf-dist-128 WS-C3524-XL Fa0/7 Fa0/24 00e0.1e7e.be80 1900_Switch 1900 Fa0/11 00e0.1e9f.7a00 Surfers-24 WS-C2924-XL Fa0/5 Fa0/3 00e0.1e9f.8c00 Surfers-12-2 WS-C2912-XL Fa0/4 Fa0/7 00e0.1e9f.8c40 Surfers-12-1 WS-C2912-XL Fa0/1 Fa0/9 Catalyst 3550 Multilayer Switch Command Reference 2-236 78-11195-09...
  • Page 263 Hops from command device: 2 Related Commands Command Description show cluster Displays the cluster status and a summary of the cluster to which the switch belongs. show cluster members Displays information about the cluster members. Catalyst 3550 Multilayer Switch Command Reference 2-237 78-11195-09...
  • Page 264: Show Cluster Members

    Switch# show cluster members |---Upstream---| SN MAC Address Name PortIf FEC Hops SN PortIf State 0002.4b29.2e00 StLouis1 (Cmdr) 0030.946c.d740 tal-switch-1 Fa0/13 Gi0/1 0002.b922.7180 nms-2820 Fa0/18 0002.4b29.4400 SanJuan2 Gi0/1 Fa0/11 0002.4b28.c480 GenieTest Gi0/2 Fa0/9 Catalyst 3550 Multilayer Switch Command Reference 2-238 78-11195-09...
  • Page 265 Device 'GenieTest' with member number 4 Device type: cisco SeaHorse MAC address: 0002.4b28.c480 Upstream MAC address: 0030.946c.d740 (Cluster member 1) Local port: Gi0/2 FEC number: Upstream port: Fa0/9 FEC Number: Hops from command device: 2 Catalyst 3550 Multilayer Switch Command Reference 2-239 78-11195-09...
  • Page 266 Hops from command device: 1 Related Commands Command Description show cluster Displays the cluster status and a summary of the cluster to which the switch belongs. show cluster candidates Displays a list of candidate switches. Catalyst 3550 Multilayer Switch Command Reference 2-240 78-11195-09...
  • Page 267: Show Controllers Cpu-Interface

    This command was first introduced. Usage Guidelines This display provides information that might be useful for Cisco technical support representatives troubleshooting the switch. Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
  • Page 268 Displays per-interface send and receive statistics read from the hardware or ethernet-controller the interface internal registers. show interfaces Displays the administrative and operational status of all interfaces or a specified interface. Catalyst 3550 Multilayer Switch Command Reference 2-242 78-11195-09...
  • Page 269: Show Controllers Ethernet-Controller

    Usage Guidelines This display without keywords provides traffic statistics, basically the RMON statistics for the interface. When you enter the asic or phy keyword, the displayed information is useful primarily for Cisco technical support representatives troubleshooting the switch. Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
  • Page 270 The number of frames that are successfully sent on an interface after two collisions occur. 3 collision frames The number of frames that are successfully sent on an interface after three collisions occur. Catalyst 3550 Multilayer Switch Command Reference 2-244 78-11195-09...
  • Page 271 The total number of frames sent on an interface that are from 512 to 1023 bytes. 1518 byte frames The total number of frames sent on an interface that are from 1024 to 1518 bytes. 1. CFI = Canonical Format Indicator Catalyst 3550 Multilayer Switch Command Reference 2-245 78-11195-09...
  • Page 272 FCS values. The frame size includes the FCS value but does not include the VLAN tag. Pause frames The number of pause frames received on an interface. Symbol error frames The number of frames received on an interface that have symbol errors. Catalyst 3550 Multilayer Switch Command Reference 2-246 78-11195-09...
  • Page 273 Displays the state of the CPU network ASIC and send and receive statistics cpu-interface for packets reaching the CPU. show interfaces Displays the administrative and operational status of all interfaces or a specified interface. Catalyst 3550 Multilayer Switch Command Reference 2-247 78-11195-09...
  • Page 274: Show Controllers Switch

    Switch# show controllers resource-allocation priority Switch Priority Resource Allocation is enabled. Related Commands Command Description switchcore resource-allocation Reserves switch resources for high-priority traffic or gives buffer priority storage more priority than packet retrieval. switchcore wirespeed-store Catalyst 3550 Multilayer Switch Command Reference 2-248 78-11195-09...
  • Page 275: Show Controllers Tcam

    This command was first introduced. Usage Guidelines This display provides information that might be useful for Cisco technical support representatives troubleshooting the switch. Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
  • Page 276 Global Mask[14]: FF FFFFFFFF FFFFFFFF Global Mask[15]: FF FFFFFFFF FFFFFFFF Global Mask[16]: FF FFFFFFFF FFFFFFFF Global Mask[20]: FF FFFFFFFF FFFFFFFF Global Mask[21]: FF FFFFFFFF FFFFFFFF Global Mask[22]: FF FFFFFFFF FFFFFFFF <output truncated> Catalyst 3550 Multilayer Switch Command Reference 2-250 78-11195-09...
  • Page 277: Show Dot1Q-Tunnel

    Switch> show dot1q-tunnel interface gigabitethernet0/1 Port ----- Gi0/1 Related Commands Command Description show vlan dot1q tag native Displays 802.1Q native VLAN tagging status. switchport mode dot1q-tunnel Configures an interface as an 802.1Q tunnel port. Catalyst 3550 Multilayer Switch Command Reference 2-251 78-11195-09...
  • Page 278: Show Dot1X

    If you specify the statistics keyword with the interface interface-id option, statistics appear for the specified interface. Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-252 78-11195-09...
  • Page 279 MaxReq HostMode = Single Port Control = Auto QuietPeriod = 60 Seconds Re-authentication = Disabled ReAuthPeriod = 3600 Seconds ServerTimeout = 30 Seconds SuppTimeout = 30 Seconds TxPeriod = 30 Seconds Guest-Vlan Catalyst 3550 Multilayer Switch Command Reference 2-253 78-11195-09...
  • Page 280 Received packets in the 802.1X version 1 format. LastRxSrcMac Source MAC address carried in the most recently received EAPOL frame. Related Commands Command Description dot1x default Resets the configurable 802.1X parameters to their default values. Catalyst 3550 Multilayer Switch Command Reference 2-254 78-11195-09...
  • Page 281: Show Env

    This is an example of output from the show env all command: Switch> show env all FAN is FAULTY TEMPERATURE is OK This is an example of output from the show env fan command: Switch> show env fan FAN is OK Catalyst 3550 Multilayer Switch Command Reference 2-255 78-11195-09...
  • Page 282 This is an example of output from the show env power command: Switch> show env power POWER is OK This is an example of output from the show env rps command: Switch> show env rps RPS is NOT PRESENT Catalyst 3550 Multilayer Switch Command Reference 2-256 78-11195-09...
  • Page 283: Show Errdisable Detect

    Enables error-disable detection for a specific cause or all causes. show errdisable flap-values Displays error condition recognition information. show errdisable recovery Displays error-disable recovery timer information. show interfaces status Displays interface status or a list of interfaces in error-disabled state. Catalyst 3550 Multilayer Switch Command Reference 2-257 78-11195-09...
  • Page 284: Show Errdisable Flap-Values

    Output appear. Examples This is an example of output from the show errdisable flap-values command: Switch> show errdisable flap-values ErrDisable Reason Flaps Time (sec) ----------------- ------ ---------- pagp-flap dtp-flap link-flap Catalyst 3550 Multilayer Switch Command Reference 2-258 78-11195-09...
  • Page 285 Enables error-disable detection for a specific cause or all causes. show errdisable detect Displays error-disable detection status. show errdisable recovery Displays error-disable recovery timer information. show interfaces status Displays interface status or a list of interfaces in error-disabled state. Catalyst 3550 Multilayer Switch Command Reference 2-259 78-11195-09...
  • Page 286: Show Errdisable Recovery

    Disabled link-flap Disabled l2ptguard Disabled psecure-violation Disabled gbic-invalid Disabled Timer interval:300 seconds Interfaces that will be enabled at the next timeout: Interface Errdisable reason Time left(sec) --------- ----------------- -------------- Gi0/4 link-flap Catalyst 3550 Multilayer Switch Command Reference 2-260 78-11195-09...
  • Page 287 Configures the recover mechanism variables. show errdisable detect Displays error disable detection status. show errdisable flap-values Displays error condition recognition information. show interfaces status Displays interface status or a list of interfaces in error-disabled state. Catalyst 3550 Multilayer Switch Command Reference 2-261 78-11195-09...
  • Page 288: Show Etherchannel

    This is an example of output from the show etherchannel 1 detail command: Switch> show etherchannel 1 detail Group state = L2 Ports: 2 Maxports = 8 Port-channels: 1 Max Port-channels = 1 Ports in the group: ------------------- Catalyst 3550 Multilayer Switch Command Reference 2-262 78-11195-09...
  • Page 289 Port-channels in the group: ---------------------- Port-channel: Po1 ------------ Age of the Port-channel = 00d:00h:08m:28s Logical slot/port = 1/0 Number of ports = 2 = 0x00010001 HotStandBy port = null Port state = Port-channel Ag-Inuse Catalyst 3550 Multilayer Switch Command Reference 2-263 78-11195-09...
  • Page 290 Gi0/1 desirable-sl Gi0/2 desirable-sl Time since last port bundled: 00d:00h:10m:08s Gi0/1 Related Commands Command Description channel-group Assigns an Ethernet interface to an EtherChannel group. interface port-channel Accesses or creates the port channel. Catalyst 3550 Multilayer Switch Command Reference 2-264 78-11195-09...
  • Page 291: Show Fm

    Switch Database Management feature to the access template. If the output shows a merge failure, the sdm prefer access global configuration command has no effect. Catalyst 3550 Multilayer Switch Command Reference 2-265 78-11195-09...
  • Page 292 Input Features: Interfaces or VLANs: Vl1 Priority:normal Vlan Map:(none) Access Group:131, 6788 VMRs Multicast Boundary:(none), 0 VMRs Output Features: Interfaces or VLANs: Priority:low Bridge Group Member:no Vlan Map:(none) Access Group:(none), 0 VMRs Catalyst 3550 Multilayer Switch Command Reference 2-266 78-11195-09...
  • Page 293 Interfaces or VLANs: Vl2 Priority:normal Bridge Group Member:no Vlan Map:(none) Access Group:bigtwo, 11 VMRs Related Commands Command Description show fm interface Displays per-interface feature manager information. show fm vlan Displays per-VLAN feature manager information. Catalyst 3550 Multilayer Switch Command Reference 2-267 78-11195-09...
  • Page 294: Show Fm Interface

    This is an example of output from the show fm interface vlan 1 command with PBR enabled on the interface. Switch# show fm interface vlan 1 Input VLAN Label: 1 Output VLAN Label: 0 (default) Policy Label: 9 Priority: normal Catalyst 3550 Multilayer Switch Command Reference 2-268 78-11195-09...
  • Page 295 Displays feature-manager information for a specified label and lists configuration conflicts or features associated with that label that were not able to fit into the hardware. show fm vlan Displays per-VLAN feature manager information. Catalyst 3550 Multilayer Switch Command Reference 2-269 78-11195-09...
  • Page 296: Show Fm Vlan

    Displays per-interface feature manager information. show fm Displays feature-manager information for a specified label and lists configuration conflicts or features associated with that label that were not able to fit into the hardware. Catalyst 3550 Multilayer Switch Command Reference 2-270 78-11195-09...
  • Page 297: Show Forward

    (Optional) Two-byte IP fragment field in the IP header. This field includes the Don’t Fragment bit (0x4000), the More Fragments bit (0x2000), and the Fragment Offset (0x0 through 0x1FFF). The default is 0x0 (unfragmented packet). Catalyst 3550 Multilayer Switch Command Reference 2-271 78-11195-09...
  • Page 298 (if applicable). The output is likely to be accurate, even if other parameters are missing or estimated. If port channel interfaces are present, it is important to specify the source MAC address and IP address correctly. Catalyst 3550 Multilayer Switch Command Reference 2-272 78-11195-09...
  • Page 299 00000404 04210000 vlan:1033, vlanid entry:0004000A 00000000 88000000 00000000 lookup bk adata rawoff secoff sec route 420808080A04040421 000000000000000000 0 3FFF800D 006361 000025 GigabitEthernet0/1 vlan 1033, dst 0000.0404.0421 src 0022.3355.8800, cos 0x0, dscp 0x0 Catalyst 3550 Multilayer Switch Command Reference 2-273 78-11195-09...
  • Page 300 00000000 00000000 00000000 00000000 globalMask: 00000000 00000000 0002FFFF EFBFFC03 forwMap: 00000000 00000000 00100000 00000000 frame notifies: src u_dat vlan fl q-map 01 00000000 00000000 00100000 00000000 Cpu q:100 - routing queue Catalyst 3550 Multilayer Switch Command Reference 2-274 78-11195-09...
  • Page 301 This name should correspond to one of the queue names in the output from the show controllers cpu-interface privileged EXEC command, where statistics appear for the number of packets received at each queue. Catalyst 3550 Multilayer Switch Command Reference 2-275 78-11195-09...
  • Page 302: Show Interfaces

    Note Though visible in the command-line help strings, the crb, fair-queue, irb, mac-accounting, precedence, private-vlan mapping, random-detect, rate-limit, and shape keywords are not supported. Command Modes Privileged EXEC Catalyst 3550 Multilayer Switch Command Reference 2-276 78-11195-09...
  • Page 303 9222 packets output, 2188728 bytes, 0 underruns 0 output errors, 0 collisions, 2 interface resets 0 babbles, 0 late collision, 1 deferred 0 lost carrier, 0 no carrier 0 output buffer failures, 0 output buffers swapped out Catalyst 3550 Multilayer Switch Command Reference 2-277 78-11195-09...
  • Page 304 This is an example of output from the show interfaces gigabitethernet0/4 description command when the interface has been described as Connects to Marketing by using the description interface configuration command. Switch# show interfaces gigabitethernet0/4 description Interface Status Protocol Description G10/4 down Connects to Marketing Catalyst 3550 Multilayer Switch Command Reference 2-278 78-11195-09...
  • Page 305 Port state = Port-channel Ag-Not-Inuse ---- Port-channel10: Age of the Port-channel = 01d:06h:06m:15s Logical slot/port = 1/0 Number of ports = 0 = 0x00000000 HotStandBy port = null Port state = Port-channel Ag-Not-Inuse Catalyst 3550 Multilayer Switch Command Reference 2-279 78-11195-09...
  • Page 306 This is an example of output from the show interfaces gigabitethernet0/9 pruning command when pruning is enabled in the VTP domain: Switch# show interfaces gigibitethernet0/9 pruning Port Vlans pruned for lack of request by neighbor Gi0/9 Port Vlans traffic requested of neighbor Gi0/9 Catalyst 3550 Multilayer Switch Command Reference 2-280 78-11195-09...
  • Page 307 Administrative private-vlan host-association:none Administrative private-vlan mapping:none Operational private-vlan:none Trunking VLANs Enabled:ALL Pruning VLANs Enabled:2-1001 Capture Mode: Disabled Capture VLANs Allowed:ALL Protected:true Unknown unicast blocked:disabled Unknown multicast blocked:disabled Voice VLAN:none (Inactive) Appliance trust:none Catalyst 3550 Multilayer Switch Command Reference 2-281 78-11195-09...
  • Page 308 Unknown multicast blocked Voice VLAN Displays the VLAN ID on which voice VLAN is enabled. Appliance trust Displays the CoS setting of the data packets of the IP phone. Catalyst 3550 Multilayer Switch Command Reference 2-282 78-11195-09...
  • Page 309 Isolates unicast, multicast, and broadcast traffic at Layer 2 from other protected ports on the same switch. switchport trunk pruning Configures the VLAN pruning-eligible list for ports in trunking mode. Catalyst 3550 Multilayer Switch Command Reference 2-283 78-11195-09...
  • Page 310: Show Interfaces Counters

    If you do not enter any keywords, all counters for all interfaces are included. Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-284 78-11195-09...
  • Page 311 Gi0/2 This is an example of output from the show interfaces counters trunk command. It displays trunk counters for all interfaces. Switch# show interfaces counters trunk Port TrunkFramesTx TrunkFramesRx WrongEncap Gi0/1 Gi0/2 Catalyst 3550 Multilayer Switch Command Reference 2-285 78-11195-09...
  • Page 312 Related Commands Command Description show interfaces Displays additional interface characteristics. show storm-control Displays storm-control settings for an interface or all interfaces. storm-control Sets storm-control broadcast, multicast, and unicast suppression levels for an interface. Catalyst 3550 Multilayer Switch Command Reference 2-286 78-11195-09...
  • Page 313: Show Ip Dhcp Snooping

    ------------------------ ------- ---------------- FastEthernet0/5 unlimited FastEthernet0/7 unlimited FastEthernet0/3 5000 FastEthernet0/5 unlimited FastEthernet0/7 unlimited FastEthernet0/5 unlimited FastEthernet0/7 unlimited Related Commands Command Description show ip dhcp snooping Displays the DHCP snooping binding information. binding Catalyst 3550 Multilayer Switch Command Reference 2-287 78-11195-09...
  • Page 314: Show Ip Dhcp Snooping Binding

    This example shows how to display the DHCP snooping binding entires for a specific IP address. Switch#show ip dhcp snooping binding 41.0.0.51 MacAddress IpAddress Lease(sec) Type VLAN Interface ------------------ --------------- ---------- ------- ---- -------------------- 00:30:94:C2:EF:35 41.0.0.51 dynamic FastEthernet0/3 Catalyst 3550 Multilayer Switch Command Reference 2-288 78-11195-09...
  • Page 315: Show Ip Dhcp Snooping Binding

    Interface ------------------ --------------- ---------- ------- ---- -------------------- 00:30:94:C2:EF:35 41.0.0.51 dynamic FastEthernet0/3 00:D0:B7:1B:35:DE 41.0.0.52 dynamic FastEthernet0/3 00:00:00:00:00:02 41.0.0.53 dynamic FastEthernet0/9 Related Commands Command Description show ip dhcp snooping Displays the DHCP snooping configuration. Catalyst 3550 Multilayer Switch Command Reference 2-289 78-11195-09...
  • Page 316: Show Ip Igmp Profile

    233.1.1.1 233.255.255.255 Switch# show ip igmp profile IGMP Profile 3 range 230.9.9.0 230.9.9.0 IGMP Profile 4 permit range 229.9.9.0 229.255.255.255 Related Commands Command Description ip igmp profile Configures the specified IGMP profile number. Catalyst 3550 Multilayer Switch Command Reference 2-290 78-11195-09...
  • Page 317: Show Ip Igmp Snooping

    IP address. Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-291 78-11195-09...
  • Page 318 This is an example of output from the show ip igmp snooping mrouter command. It shows how to display multicast router ports on the switch. Switch> show ip igmp snooping mrouter vlan ports -----+---------------------------------------- Gi0/1,Gi0/1, Router Gi0/3,Gi0/4 Catalyst 3550 Multilayer Switch Command Reference 2-292 78-11195-09...
  • Page 319 Enables and configures the aging time of the forward-table source-only-learning age-timer entries that the switch learns by using the source-only learning method. show mac address-table multicast Displays the Layer 2 multicast entries for a VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-293 78-11195-09...
  • Page 320: Show L2Protocol-Tunnel

    Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-294 78-11195-09...
  • Page 321 ----/----/---- ----/----/---- down pagp ---- udld ----/----/---- ----/----/---- Fa0/16 cdp stp vtp ----/----/---- ----/----/---- down pagp lacp udld ----/----/---- ----/----/---- Fa0/17 cdp stp vtp ----/----/---- ----/----/---- down pagp lacp udld ----/----/---- ----/----/---- Catalyst 3550 Multilayer Switch Command Reference 2-295 78-11195-09...
  • Page 322 Clears counters for protocol tunneling ports. l2protocol-tunnel Enables Layer 2 protocol tunneling for CDP, STP, or VTP packets on an interface. l2protocol-tunnel cos Configures a class of service (CoS) value for tunneled Layer 2 protocol packets. Catalyst 3550 Multilayer Switch Command Reference 2-296 78-11195-09...
  • Page 323: Show L2Tcam

    {cam {forwarding [entry-id] learning} | shadow} [ | {begin | exclude | include} expression] Syntax Description Display contents and associated information about TCAM Layer 2 contents. This display output is a raw hex dump of information, intended for a Cisco technical support representative. forwarding Display TCAM Layer 2 forwarding (bridging) information.
  • Page 324 1811 1810 2/14 Related Commands Command Description show l3tcam Displays information about the TCAM devoted to Layer 3 forwarding information. show mac address-table Displays the MAC address table static and dynamic entries. Catalyst 3550 Multilayer Switch Command Reference 2-298 78-11195-09...
  • Page 325: Show L3Tcam

    This command was first introduced. Usage Guidelines This display provides information that might be useful for Cisco technical support representatives troubleshooting the switch. Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
  • Page 326 Release 12.1 > IP Addressing and Services > Commands. show arp Displays the entries in the ARP table. For syntax information, select Cisco IOS IP and IP Routing Command Reference for IOS Release 12.1 > IP Addressing and Services > IP Addressing Commands.
  • Page 327: Show Lacp

    This is an example of output from the show lacp counters command: Switch> show lacp counters LACPDUs Marker Marker Response LACPDUs Port Sent Recv Sent Recv Sent Recv Pkts Err --------------------------------------------------------------------- Channel group:1 Fa0/5 Fa0/6 Fa0/7 Catalyst 3550 Multilayer Switch Command Reference 2-301 78-11195-09...
  • Page 328 Port State 32768 0x35 This is an example of output from the show lacp sys-id command: Switch> show lacp sys-id 32765,0002.4b29.3a00 Related Commands Command Description clear lacp Clears the LACP channel-group information. Catalyst 3550 Multilayer Switch Command Reference 2-302 78-11195-09...
  • Page 329: Show Mac Access-Group

    Inbound access-list is not set Interface GigabitEthernet0/5: Inbound access-list is not set <output truncated> Interface GigabitEthernet0/10: Inbound access-list is not set Interface GigabitEthernet0/11: Inbound access-list is not set Interface GigabitEthernet0/12: Inbound access-list is not set Catalyst 3550 Multilayer Switch Command Reference 2-303 78-11195-09...
  • Page 330 This is an example of output from the show mac access-group interface gigabitethernet 0/2 command: Switch# show mac access-group interface gigabitethernet 0/2 Interface GigabitEthernet0/2: Inbound access-list is macl_e1 Related Commands Command Description mac access-group Applies a MAC access group to an interface. Catalyst 3550 Multilayer Switch Command Reference 2-304 78-11195-09...
  • Page 331: Show Mac Address-Table

    [ | {begin | exclude | include} expression] Note Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table command replaces the show mac-address-table command (with the hyphen). Syntax Description | begin (Optional) Display begins with the line that matches the expression.
  • Page 332 Displays the MAC address notification settings for all interfaces or the specified interface. show mac address-table static Displays static MAC address table entries only. show mac address-table vlan Displays the MAC address table information for the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-306 78-11195-09...
  • Page 333: Show Mac Address-Table Address

    MAC address. show mac address-table address mac-address [interface interface-id] [vlan vlan-id] [ | {begin | exclude | include} expression] Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table address command Note replaces the show mac-address-table address command (with the hyphen).
  • Page 334 Displays the MAC address notification settings for all interfaces or the specified interface. show mac address-table static Displays static MAC address table entries only. show mac address-table vlan Displays the MAC address table information for the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-308 78-11195-09...
  • Page 335: Show Mac Address-Table Aging-Time

    VLANs or the specified VLAN. show mac address-table aging-time [vlan vlan-id] [ | {begin | exclude | include} expression] Note Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table aging-time command replaces the show mac-address-table aging-time command (with the hyphen). Syntax Description vlan vlan-id (Optional) Display aging time information for a specific VLAN.
  • Page 336 Displays the MAC address notification settings for all interfaces notification or the specified interface. show mac address-table static Displays static MAC address table entries only. show mac address-table vlan Displays the MAC address table information for the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-310 78-11195-09...
  • Page 337: Show Mac Address-Table Count

    VLANs or the specified VLAN. show mac address-table count [vlan vlan-id] [ | {begin | exclude | include} expression] Note Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table count command replaces the show mac-address-table count command (with the hyphen). Syntax Description vlan vlan-id (Optional) Display the number of addresses for a specific VLAN.
  • Page 338 Displays the MAC address notification settings for all notification interfaces or the specified interface. show mac address-table static Displays static MAC address table entries only. show mac address-table vlan Displays the MAC address table information for the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-312 78-11195-09...
  • Page 339: Show Mac Address-Table Dynamic

    [address mac-address] [interface interface-id] [vlan vlan-id] [ | {begin | exclude | include} expression] Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table dynamic command Note replaces the show mac-address-table dynamic command (with the hyphen).
  • Page 340 Displays the MAC address notification settings for all interfaces or the specified interface. show mac address-table static Displays static MAC address table entries only. show mac address-table vlan Displays the MAC address table information for the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-314 78-11195-09...
  • Page 341: Show Mac Address-Table Interface

    VLAN. show mac address-table interface interface-id [vlan vlan-id] [ | {begin | exclude | include} expression] Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table interface command Note replaces the show mac-address-table interface command (with the hyphen).
  • Page 342 Displays the MAC address notification settings for all interfaces or the specified interface. show mac address-table static Displays static MAC address table entries only. show mac address-table vlan Displays the MAC address table information for the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-316 78-11195-09...
  • Page 343: Show Mac Address-Table Multicast

    [count] | igmp-snooping [count] | user [count] | vlan [count] | [vlan-id [count] | igmp-snooping [count] | user [count]] [ | {begin | exclude | include} expression] Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table multicast command Note replaces the show mac-address-table multicast command (with the hyphen).
  • Page 344 Displays the MAC address notification settings for all interfaces or the specified interface. show mac address-table static Displays static MAC address table entries only. show mac address-table vlan Displays the MAC address table information for the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-318 78-11195-09...
  • Page 345: Show Mac Address-Table Notification

    [interface [interface-id] [ | {begin | exclude | include} expression] Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table notification command Note replaces the show mac-address-table notification command (with the hyphen).
  • Page 346 Displays the Layer 2 multicast entries for all VLANs or the specified VLAN. show mac address-table static Displays static MAC address table entries only. show mac address-table vlan Displays the MAC address table information for the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-320 78-11195-09...
  • Page 347: Show Mac Address-Table Static

    [[address mac-address [interface interface-id | vlan vlan-id]] | [interface interface-id [vlan vlan-id]] | vlan vlan-id] [ | {begin | exclude | include} expression] Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table static command replaces Note the show mac-address-table static command (with the hyphen).
  • Page 348 VLAN. show mac address-table notification Displays the MAC address notification settings for all interfaces or the specified interface. show mac address-table vlan Displays the MAC address table information for the specified VLAN. Catalyst 3550 Multilayer Switch Command Reference 2-322 78-11195-09...
  • Page 349: Show Mac Address-Table Vlan

    VLAN. show mac address-table vlan vlan-id [ | {begin | exclude | include} expression] Note Beginning with Cisco IOS Release 12.1(11)EA1, the show mac address-table vlan command replaces the show mac-address-table vlan command (with the hyphen). Syntax Description vlan-id (Optional) Display addresses for a specific VLAN.
  • Page 350 Displays the Layer 2 multicast entries for all VLANs or the specified VLAN. show mac address-table notification Displays the MAC address notification settings for all interfaces or the specified interface. show mac address-table static Displays static MAC address table entries only. Catalyst 3550 Multilayer Switch Command Reference 2-324 78-11195-09...
  • Page 351: Show Mls Qos

    This is an example of output from the show mls qos command: Switch> show mls qos Qos is enabled Related Commands Command Description mls qos Enables quality of service (QoS) for the entire switch. Catalyst 3550 Multilayer Switch Command Reference 2-325 78-11195-09...
  • Page 352: Show Mls Qos Aggregate-Policer

    88000 2000000 exceed-action drop Not used by any policy map Related Commands Command Description mls qos aggregate-policer Defines policer parameters that can be shared by multiple classes within a policy map. Catalyst 3550 Multilayer Switch Command Reference 2-326 78-11195-09...
  • Page 353: Show Mls Qos Interface

    (Optional) Display includes lines that match the specified expression. expression Expression in the output to use as a reference point. Command Modes User EXEC Command History Release Modification 12.1(4)EA1 This command was first introduced. Catalyst 3550 Multilayer Switch Command Reference 2-327 78-11195-09...
  • Page 354 This is an example of output from the show mls qos interface gigabitethernet0/1 queueing command: Switch> show mls qos interface gigabitethernet0/1 queueing GigabitEthernet0/1 Ingress expedite queue: dis Egress expedite queue: ena wrr bandwidth weights: Catalyst 3550 Multilayer Switch Command Reference 2-328 78-11195-09...
  • Page 355 2 : 0 3 : 0 45: 0 23: 0 Others: 155983 WRED drop counts: thresh1 thresh2 FreeQ 1 : 0 1024 2 : 0 1024 3 : 0 1024 4 : 0 1024 Catalyst 3550 Multilayer Switch Command Reference 2-329 78-11195-09...
  • Page 356 FreeQ Amount of free queue space available per queue. Related Commands Command Description mls qos monitor Defines up to 16 DSCP values for which byte or packet statistics are gathered by hardware. Catalyst 3550 Multilayer Switch Command Reference 2-330 78-11195-09...
  • Page 357: Show Mls Qos Maps

    This command was first introduced. Usage Guidelines Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-331 78-11195-09...
  • Page 358 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 Catalyst 3550 Multilayer Switch Command Reference 2-332 78-11195-09...
  • Page 359 DSCP-to-CoS map, an internal DSCP value of 43 corresponds to a CoS value of 5. Related Commands Command Description mls qos map Defines the CoS-to-DSCP map, DSCP-to-CoS map, DSCP-to-DSCP-mutation map, IP-precedence-to-DSCP map, and the policed-DSCP map. Catalyst 3550 Multilayer Switch Command Reference 2-333 78-11195-09...
  • Page 360: Show Monitor

    The range keyword was added. Usage Guidelines Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-334 78-11195-09...
  • Page 361 Starts a new SPAN or RSPAN session, adds or deletes interfaces or VLANs to or from an existing SPAN or RSPAN session, and filters SPAN source traffic to specific source VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-335 78-11195-09...
  • Page 362: Show Mvr

    (for inter-operability with Catalyst 2900 XL and Catalyst 3500 XL switches) or dynamic (where operation is consistent with IGMP snooping operation and dynamic MVR membership on source ports is supported). Catalyst 3550 Multilayer Switch Command Reference 2-336 78-11195-09...
  • Page 363 Displays all ports that are members of an MVR multicast group or, if there are no members, means the group is inactive. Catalyst 3550 Multilayer Switch Command Reference 2-337 78-11195-09...
  • Page 364: Show Mvr Interface

    This is an example of output from the show mvr interface command: Switch# show mvr interface Port Type Status Immediate Leave ---- ---- ------- --------------- Gi0/1 SOURCE ACTIVE/UP DISABLED Gi0/2 RECEIVER ACTIVE/DOWN DISABLED Gi0/5 RECEIVER ACTIVE/UP ENABLED Catalyst 3550 Multilayer Switch Command Reference 2-338 78-11195-09...
  • Page 365 (interface configuration) Configures MVR ports. show mvr Displays the global MVR configuration on the switch. show mvr members Displays all receiver ports that are members of an MVR multicast group. Catalyst 3550 Multilayer Switch Command Reference 2-339 78-11195-09...
  • Page 366: Show Mvr Members

    239.255.0.3 INACTIVE None 239.255.0.4 INACTIVE None 239.255.0.5 INACTIVE None 239.255.0.6 INACTIVE None 239.255.0.7 INACTIVE None 239.255.0.8 INACTIVE None 239.255.0.9 INACTIVE None 239.255.0.10 INACTIVE None <output truncated> 239.255.0.255 INACTIVE None 239.255.1.0 INACTIVE None Catalyst 3550 Multilayer Switch Command Reference 2-340 78-11195-09...
  • Page 367 Displays the global MVR configuration on the switch. show mvr interface Displays the configured MVR interfaces, status of the specified interface, or all multicast groups to which the interface belongs when the members keyword is appended to the command. Catalyst 3550 Multilayer Switch Command Reference 2-341 78-11195-09...
  • Page 368: Show Pagp

    Examples This is an example of output from the show pagp 1 counters command: Switch> show pagp 1 counters Information Flush Port Sent Recv Sent Recv -------------------------------------- Channel group: 1 Gi0/1 Gi0/2 Catalyst 3550 Multilayer Switch Command Reference 2-342 78-11195-09...
  • Page 369 Partner Group Port Name Device ID Port Flags Cap. Gi0/1 vegas-p2 0002.4b29.4600 Gi0/1 9s SC 10001 Gi0/2 vegas-p2 0002.4b29.4600 Gi0/2 24s SC 10001 Related Commands Command Description clear pagp Clears PAgP channel-group information. Catalyst 3550 Multilayer Switch Command Reference 2-343 78-11195-09...
  • Page 370: Show Parser Macro

    # Allow port channels to be automatically formed channel-protocol pagp -------------------------------------------------------------- Macro name : testm Macro type : customizable macro description this is test macro speed 100 -------------------------------------------------------------- Catalyst 3550 Multilayer Switch Command Reference 2-344 78-11195-09...
  • Page 371 Apply a macro on an interface, or apply and trace a macro on an interface. macro description Add a description about the macros that are applied to an interface. macro name Create a macro. Catalyst 3550 Multilayer Switch Command Reference 2-345 78-11195-09...
  • Page 372: Show Policy-Map

    The class keyword was added. Usage Guidelines Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-346 78-11195-09...
  • Page 373 Defines the class of service (CoS) value of a port in a policy map. policy-map Creates or modifies a policy map that can be attached to multiple interfaces to specify a service policy. Catalyst 3550 Multilayer Switch Command Reference 2-347 78-11195-09...
  • Page 374: Show Port-Security

    Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-348 78-11195-09...
  • Page 375 Max Addresses limit in System :6176 This is an example of output from the show port-security interface fastethernet0/2 vlan command: Switch# show port-security interface fastethernet0/2 vlan Default maximum: not set, using 6176 VLAN Maximum Current default Catalyst 3550 Multilayer Switch Command Reference 2-349 78-11195-09...
  • Page 376 ------------------------------------------------------------------- Total Addresses:3 Related Commands Command Description switchport port-security Enables port security on a port, restricts the use of the port to a user-defined group of stations, and configures secure MAC addresses. Catalyst 3550 Multilayer Switch Command Reference 2-350 78-11195-09...
  • Page 377: Show Power Inline

    Use the show power inline user EXEC command to display the inline power state for a specific Fast Ethernet interface or for all Fast Ethernet interfaces on the Catalyst 3550-24PWR switch. show power inline [interface-id] | {begin | exclude | include} expression] Note This command is available only on the Catalyst 3550-24PWR switches.
  • Page 378 Description Interface Type of interface. Admin Administrative mode. Oper Operating mode. Power Cisco devices show reported power; IEEE devices show 15 W. Device The type of device detected. Class Class type of IEEE Power Device. Related Commands Command Description power inline Sets the inline-power state for inline-power-capable interfaces.
  • Page 379: Show Running-Config Vlan

    Examples This is an example of output from the show running-config vlan command: Switch# show running-config vlan 900-2005 Building configuration... Current configuration: vlan 907 vlan 920 vlan 1025 vlan 2000 vlan 2001 Catalyst 3550 Multilayer Switch Command Reference 2-353 78-11195-09...
  • Page 380 Displays the running configuration on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. vlan (global Enters config-vlan mode for creating and editing VLANs. When VLAN...
  • Page 381: Show Sdm Prefer

    MAC addresses might be less than 6000. Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-355 78-11195-09...
  • Page 382 Sets the SDM template to maximize feature resource utilization for QoS classification and security ACEs, routing, or VLANs, or to the default template, or to reformat memory space to support 144-bit Layer 3 TCAM. Catalyst 3550 Multilayer Switch Command Reference 2-356 78-11195-09...
  • Page 383: Show Setup Express

    Switch# show setup express express setup mode is active Related Commands Command Description clear setup express Exits Express Setup mode without saving the configuration. setup express Enables Express Setup mode on the switch. Catalyst 3550 Multilayer Switch Command Reference 2-357 78-11195-09...
  • Page 384: Show Spanning-Tree

    | portfast | supported. Valid interfaces include physical ports, VLANs, and port priority | rootcost | state] channels. The valid VLAN range is 1 to 4094. The valid port-channel range is 1 to 64. Catalyst 3550 Multilayer Switch Command Reference 2-358 78-11195-09...
  • Page 385 User EXEC; indicated keywords available only in privileged EXEC mode Command History Release Modification 12.1(4)EA1 This command was first introduced. 12.1(9)EA1 The mst keyword and options were added. The brief keyword was removed, and the detail keyword was added. Catalyst 3550 Multilayer Switch Command Reference 2-359 78-11195-09...
  • Page 386 Designated port id is 128.26, designated path cost 19 Timers: message age 3, forward delay 0, hold 0 Number of transitions to forwarding state: 1 Link type is point-to-point by default BPDU: sent 0, received 947349 <output truncated> Catalyst 3550 Multilayer Switch Command Reference 2-360 78-11195-09...
  • Page 387 :disable (default) Bpdus sent 84122, received 83933 Instance Role Sts Cost Prio.Nbr Vlans mapped -------- ---- --- --------- -------- ------------------------------- Desg FWD 200000 128.1 101-4094 Root FWD 200000 128.1 1-100 Catalyst 3550 Multilayer Switch Command Reference 2-361 78-11195-09...
  • Page 388 Sets the number of hops in an MST region before the BPDU is discarded and the information held for a port is aged. spanning-tree mst port-priority Configures an interface priority. spanning-tree mst priority Configures the switch priority for the specified spanning-tree instance. Catalyst 3550 Multilayer Switch Command Reference 2-362 78-11195-09...
  • Page 389 Accelerates the choice of a new root port when a link or switch fails or when the spanning tree reconfigures itself. spanning-tree vlan Configures spanning tree on a per-VLAN basis. Catalyst 3550 Multilayer Switch Command Reference 2-363 78-11195-09...
  • Page 390: Show Storm-Control

    Current --------- ------------- ------- ------- Fa0/1 inactive 100.00% Fa0/2 inactive 100.00% Fa0/3 inactive 100.00% Fa0/4 inactive 100.00% Fa0/5 inactive 100.00% Fa0/6 inactive 100.00% Fa0/7 Forwarding 50.00% 0.00% Fa0/8 inactive 100.00% <output truncated> Catalyst 3550 Multilayer Switch Command Reference 2-364 78-11195-09...
  • Page 391 (broadcast, multicast, or unicast) as a percentage of total available bandwidth. This field is only valid when storm control is enabled. Related Commands Command Description storm-control Sets the broadcast, multicast, or unicast storm control levels for the switch. Catalyst 3550 Multilayer Switch Command Reference 2-365 78-11195-09...
  • Page 392: Show System Mtu

    This is an example of output from the show system mtu command: Switch# show system mtu System MTU size is 1500 bytes Related Commands Command Description system mtu Sets the maximum transmission unit (MTU) size for the switch. Catalyst 3550 Multilayer Switch Command Reference 2-366 78-11195-09...
  • Page 393: Show Tcam

    (see the show fm command). Port labels are used for port ACLs. This display output is a raw hex dump of information, intended for a Cisco technical support representative. The label ID range is 0 to 127. size Display the total size of the regions of TCAM in which the ACLs are entered.
  • Page 394 Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. These displays provide information that might be useful for Cisco technical support representatives troubleshooting the switch.
  • Page 395 Displays feature-manager information for a specified label to list features associated with the label that were not able to fit into hardware. Catalyst 3550 Multilayer Switch Command Reference 2-369 78-11195-09...
  • Page 396: Show Tcam Pbr

    PBR. vlan-labels [label-id] Display entries and associated information for a PBR VLAN label. This display output is a raw hex dump of information intended for a Cisco technical support representative. The label ID range is 0 to 255. masks [mask-id] Display mask information.
  • Page 397 You can use the show fm interface interface-id command to display the policy label for the interface on which PBR is enabled. These displays provide information that might be useful for Cisco technical support representatives troubleshooting the switch.
  • Page 398 F1 FF FF FF 00 FF FF FF 00 80 FF 00 00 00 00 00 00 00 Entry Index : 1 Timestamp: 4 C0 0A 01 02 00 0A 04 05 00 80 09 00 00 00 00 00 00 00 As Data(hex) : 00048000 Catalyst 3550 Multilayer Switch Command Reference 2-372 78-11195-09...
  • Page 399: Show Tcam Qos

    The entry ID range is 0 to 65535. port-labels [label-id] Display entries and associated information for a QoS port label. This display output is a raw hex dump of information intended for a Cisco technical support representative. The label ID range is 0 to 255. vlan-labels [label-id] Display entries and associated information for a QoS VLAN label.
  • Page 400 QoS information. You also can use the show tcam qos tcam-id port-labels [label-id] vlan-labels [label-id] command to display per-port per-VLAN TCAM entries with both the port label and the VLAN label. These displays provide information that might be useful for Cisco technical support representatives troubleshooting the switch. Examples This is an example of output from the show tcam qos masks command for TCAM 2: Switch>...
  • Page 401: Show Udld

    Expiration time: 146 Device ID: 1 Current neighbor state: Bidirectional Device name: 0050e2826000 Port ID: Gi0/12 Neighbor echo 1 device: SAD03160954 Neighbor echo 1 port: Gi0/11 Message interval: 5 CDP Device name: 066527791 Catalyst 3550 Multilayer Switch Command Reference 2-375 78-11195-09...
  • Page 402 The port number ID of the neighbor from which the echo originated. Message interval The rate, in seconds, at which the neighbor is sending advertisement messages. CDP device name CDP name of the device. Catalyst 3550 Multilayer Switch Command Reference 2-376 78-11195-09...
  • Page 403 Enables UDLD on an individual interface or prevents a fiber-optic interface from being enabled by the udld global configuration command. udld reset Resets all interfaces shutdown by UDLD and permits traffic to begin passing through them again. Catalyst 3550 Multilayer Switch Command Reference 2-377 78-11195-09...
  • Page 404: Show Version

    This is an example of output from the show version command: Switch> show version Cisco Internetwork Operating System Software IOS (tm) C3550 Software (C3550-I5Q3L2-M), Version 12.1(0.0.413)EA1, CISCO DEVELOPMENT TEST VERSION Copyright (c) 1986-2002 by cisco Systems, Inc. Compiled Tue 28-May-02 07:06 by antonino...
  • Page 405 Ethernet-controller 12 has 1 Gigabit Ethernet/IEEE 802.3 interface 12 Gigabit Ethernet/IEEE 802.3 interface(s) The password-recovery mechanism is enabled. 384K bytes of flash-simulated non-volatile configuration memory. Base ethernet MAC Address: 00:02:4B:29:2B:00 Configuration register is 0x10F Catalyst 3550 Multilayer Switch Command Reference 2-379 78-11195-09...
  • Page 406: Show Vlan

    The value for id vlan-id was changed. Usage Guidelines Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear. Catalyst 3550 Multilayer Switch Command Reference 2-380 78-11195-09...
  • Page 407 Media type of the VLAN. SAID Security association ID value for the VLAN. Maximum transmission unit size for the VLAN. Parent Parent VLAN, if one exists. RingNo Ring number for the VLAN, if applicable. Catalyst 3550 Multilayer Switch Command Reference 2-381 78-11195-09...
  • Page 408 ---- ----- ---------- ----- ------ ------ -------- ---- -------- ------ ------ 2005 enet 102005 1500 This is an example of output from the show vlan dot1q tag native command: Switch> show vlan dot1q tag native dot1q native vlan tagging is disabled Catalyst 3550 Multilayer Switch Command Reference 2-382 78-11195-09...
  • Page 409 Enables config-vlan mode where you can configure VLANs 1 to 4094. configuration) vlan (VLAN Configures VLAN characteristics in the VLAN database. Only available for configuration) normal-range VLANs (VLAN IDs 1 to 1005). Catalyst 3550 Multilayer Switch Command Reference 2-383 78-11195-09...
  • Page 410: Show Vlan Access-Map

    Displays information about all VLAN filters or about a particular VLAN or VLAN access map. vlan access-map Creates a VLAN map entry for VLAN packet filtering. vlan filter Applies a VLAN map to one or more VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-384 78-11195-09...
  • Page 411: Show Vlan Filter

    Displays information about a particular VLAN access map or all VLAN access maps. vlan access-map Creates a VLAN map entry for VLAN packet filtering. vlan filter Applies a VLAN map to one or more VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-385 78-11195-09...
  • Page 412: Show Vmps

    This is an example of output from the show vmps statistics command. Table 2-26 describes each field in the display. Switch> show vmps statistics VMPS Client Statistics ---------------------- Queries: Responses: VMPS Changes: Shutdowns: Denied: Wrong Domain: Catalyst 3550 Multilayer Switch Command Reference 2-386 78-11195-09...
  • Page 413 Sends VQP queries to reconfirm all dynamic VLAN assignments with the (privileged EXEC) VMPS. vmps retry Configures the per-server retry count for the VQP client. vmps server Configures the primary VMPS and up to three secondary servers. Catalyst 3550 Multilayer Switch Command Reference 2-387 78-11195-09...
  • Page 414: Show Vtp

    Number of config revision errors Number of config digest errors Number of V1 summary errors VTP pruning statistics: Trunk Join Transmitted Join Received Summary advts received from non-pruning-capable device ---------------- ---------------- ---------------- --------------------------- Fa0/9 Fa0/10 Fa0/11 Catalyst 3550 Multilayer Switch Command Reference 2-388 78-11195-09...
  • Page 415 To solve this problem, make sure the VTP password on all switches is the same. These errors mean that the switch is filtering incoming advertisements, which causes the VTP database to become unsynchronized across the network. Catalyst 3550 Multilayer Switch Command Reference 2-389 78-11195-09...
  • Page 416 1 but can be set to version 2. Configuration Revision Current configuration revision number on this switch. Maximum VLANs Maximum number of VLANs supported locally. Supported Locally Number of Existing Number of existing VLANs. VLANs Catalyst 3550 Multilayer Switch Command Reference 2-390 78-11195-09...
  • Page 417 Configures the VTP filename, interface name, domain name, and mode. vtp (privileged EXEC) Configures the VTP password, pruning, and version. vtp (VLAN configuration) Configures the VTP domain name, password, pruning, and mode. Catalyst 3550 Multilayer Switch Command Reference 2-391 78-11195-09...
  • Page 418: Shutdown

    You can verify your settings by entering the show interfaces privileged EXEC command. Related Commands Command Description show interfaces Displays the statistical information specific to all interfaces or to a specific interface. Catalyst 3550 Multilayer Switch Command Reference 2-392 78-11195-09...
  • Page 419: Shutdown Vlan

    Related Commands Command Description shutdown Shuts down local traffic on the VLAN when in config-VLAN mode (accessed by the (config-vlan mode) vlan vlan-id global configuration command). vlan database Enters VLAN configuration mode. Catalyst 3550 Multilayer Switch Command Reference 2-393 78-11195-09...
  • Page 420: Snmp-Server Enable Traps

    (Optional) Enable SNMP coldstart traps. linkdown (Optional) Enable SNMP linkdown traps. linkup (Optional) Enable SNMP linkup traps. warmstart (Optional) Enable SNMP warmstart traps. stpx (Optional) Enable SNMP STPX MIB traps. syslog (Optional) Enable SNMP syslog traps. Catalyst 3550 Multilayer Switch Command Reference 2-394 78-11195-09...
  • Page 421 Use the snmp-server enable traps command to enable sending of traps or informs, when supported. Note Informs are not supported in SNMPv1. To enable more than one type of trap, you must enter a separate snmp-server enable traps command for each trap type. Catalyst 3550 Multilayer Switch Command Reference 2-395 78-11195-09...
  • Page 422 Displays the running configuration on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. snmp-server host Specifies the host that receives SNMP traps.
  • Page 423: Snmp-Server Host

    (Optional) Send cluster member status traps. config (Optional) Send SNMP configuration traps. copy-config (Optional) Send SNMP copy configuration traps. entity (Optional) Send SNMP entity traps. envmon (Optional) Send environmental monitor (EnvMon) traps. Catalyst 3550 Multilayer Switch Command Reference 2-397 78-11195-09...
  • Page 424 The mac-notification keyword was added. 12.1(9)EA1 The vlan-membership keyword was added. 12.1(11)EA1 The version 3 option was added, with the auth, noauth, and priv keywords. The bgp keyword was added. 12.1(12c)EA1 The envmon keyword was added. Catalyst 3550 Multilayer Switch Command Reference 2-398 78-11195-09...
  • Page 425 Switch(config)# snmp-server community comaccess ro 10 Switch(config)# snmp-server host 172.20.2.160 comaccess Switch(config)# access-list 10 deny any This example shows how to enable the switch to send EnvMon traps to the host myhost.cisco.com using the community string public: Switch(config)# snmp-server host myhost.cisco.com version 2c public envmon This example shows how to send the SNMP traps to the host specified by the name myhost.cisco.com.
  • Page 426 Chapter 2 Cisco IOS Commands snmp-server host This example shows how to enable the switch to send all traps to the host myhost.cisco.com by using the community string public: Switch(config)# snmp-server enable traps Switch(config)# snmp-server host myhost.cisco.com public You can verify your settings by entering the show running-config privileged EXEC command.
  • Page 427: Snmp-Server Ip

    Switch(config)# snmp-server ip precedence 5 This example shows how to set the DSCP marking to 40: Switch(config)# snmp-server ip dscp 40 You can verify your setting by entering the show running-config privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-401 78-11195-09...
  • Page 428 Displays the running configuration on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. snmp-server host Specifies the host that receives SNMP traps.
  • Page 429: Snmp Trap Mac-Notification

    This example shows how to enable the MAC notification trap when a MAC address is added to Fast Ethernet interface 0/4: Switch(config)# interface fastethernet0/4 Switch(config-if)# snmp trap mac-notification added You can verify your settings by entering the show mac address-table notification interface privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-403 78-11195-09...
  • Page 430 Displays the MAC address notification settings for all interfaces or on the specified interface when the interface keyword is appended. snmp-server enable traps Sends the SNMP MAC notification traps when the mac-notification keyword is appended. Catalyst 3550 Multilayer Switch Command Reference 2-404 78-11195-09...
  • Page 431: Spanning-Tree Backbonefast

    Switch(config)# spanning-tree backbonefast You can verify your setting by entering the show spanning-tree summary privileged EXEC command. Related Commands Command Description show spanning-tree summary Displays a summary of the spanning-tree port states. Catalyst 3550 Multilayer Switch Command Reference 2-405 78-11195-09...
  • Page 432: Spanning-Tree Bpdufilter

    You can use the spanning-tree bpdufilter interface configuration command to override the setting of the spanning-tree portfast bpdufilter default global configuration command. When you configure Layer 2 protocol filtering, the spanning-tree BPDU filtering feature is automatically enabled on the port. Catalyst 3550 Multilayer Switch Command Reference 2-406 78-11195-09...
  • Page 433 Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. spanning-tree portfast (global Globally enables the BPDU filtering or the BPDU guard feature...
  • Page 434: Spanning-Tree Bpduguard

    This example shows how to enable the BPDU guard feature on a port: Switch(config)# interface fastethernet0/1 Switch(config-if)# spanning-tree bpduguard enable You can verify your setting by entering the show running-config privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-408 78-11195-09...
  • Page 435 Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. spanning-tree portfast (global Globally enables the BPDU filtering or the BPDU guard feature...
  • Page 436: Spanning-Tree Cost

    This example shows how to set a path cost of 250 on an interface: Switch(config)# interface fastethernet0/4 Switch(config-if)# spanning-tree cost 250 This example shows how to set a path cost of 300 for VLAN 10: Switch(config-if)# spanning-tree vlan 10 cost 300 Catalyst 3550 Multilayer Switch Command Reference 2-410 78-11195-09...
  • Page 437 Related Commands Command Description show spanning-tree interface Displays spanning-tree information for the specified interface. interface-id spanning-tree port-priority Configures an interface priority. spanning-tree vlan priority Sets the switch priority for the specified spanning-tree instance. Catalyst 3550 Multilayer Switch Command Reference 2-411 78-11195-09...
  • Page 438: Spanning-Tree Etherchannel Guard Misconfig

    Examples This example shows how to enable the EtherChannel guard feature: Switch(config)# spanning-tree etherchannel guard misconfig You can verify your settings by entering the show spanning-tree summary privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-412 78-11195-09...
  • Page 439 Displays EtherChannel information for a channel as a one-line summary for each channel group. show interfaces status Displays the interfaces in the error-disabled state. err-disabled Catalyst 3550 Multilayer Switch Command Reference 2-413 78-11195-09...
  • Page 440: Spanning-Tree Extend System-Id

    This command was first introduced. Usage Guidelines In Cisco IOS Release 12.1(8)EA1 and later, Catalyst 3550 switches support the 802.1T spanning-tree extensions, and some of the bits previously used for the switch priority are now used for the extended system ID (VLAN identifier for the per-VLAN spanning-tree plus [PVST+] and rapid PVST+ or an instance identifier for the multiple spanning tree [MST]).
  • Page 441 Displays a summary of spanning-tree port states. spanning-tree mst root Configures the multiple spanning-tree (MST) root switch priority and timers based on the network diameter. spanning-tree vlan priority Sets the switch priority for the specified spanning-tree instance. Catalyst 3550 Multilayer Switch Command Reference 2-415 78-11195-09...
  • Page 442: Spanning-Tree Guard

    UplinkFast feature are placed in the root-inconsistent state (blocked) and prevented from reaching the forwarding state. The UplinkFast feature is not available when the switch is operating in rapid-PVST+ or MST mode. Catalyst 3550 Multilayer Switch Command Reference 2-416 78-11195-09...
  • Page 443 Description show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. spanning-tree cost Sets the path cost for spanning-tree calculations.
  • Page 444: Spanning-Tree Link-Type

    You can verify your settings by entering the show spanning-tree mst interface interface-id privileged EXEC command. Related Commands Command Description show spanning-tree mst interface Displays multiple spanning-tree (MST) information for the interface-id specified interface. Catalyst 3550 Multilayer Switch Command Reference 2-418 78-11195-09...
  • Page 445: Spanning-Tree Loopguard Default

    Examples This example shows how to globally enable loop guard: Switch(config)# spanning-tree loopguard default You can verify your settings by entering the show running-config privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-419 78-11195-09...
  • Page 446 Description show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. spanning-tree guard loop Enables the loop guard feature on all the VLANs associated with the specified interface.
  • Page 447: Spanning-Tree Mode

    This example shows to enable MST on the switch: Switch(config)# spanning-tree mode mst This example shows to enable rapid PVST+ on the switch: Switch(config)# spanning-tree mode rapid-pvst You can verify your setting by entering the show running-config privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-421 78-11195-09...
  • Page 448 Command Description show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-422 78-11195-09...
  • Page 449: Spanning-Tree Mst Configuration

    [current | pending]: displays the current or pending MST region configuration. In MST mode, the switch supports up to 16 MST instances. The number of VLANs that can be mapped to a particular MST instance is unlimited. Catalyst 3550 Multilayer Switch Command Reference 2-423 78-11195-09...
  • Page 450 Switch(config-mst)# instance 10 vlan 10 Switch(config-mst)# no instance 2 You can verify your settings by entering the show pending MST configuration command. Related Commands Command Description show spanning-tree mst configuration Displays the MST region configuration. Catalyst 3550 Multilayer Switch Command Reference 2-424 78-11195-09...
  • Page 451: Spanning-Tree Mst Cost

    This example shows how to set a path cost of 250 on an interface associated with instances 2 and 4: Switch(config)# interface fastethernet0/4 Switch(config-if)# spanning-tree mst 2,4 cost 250 You can verify your settings by entering the show spanning-tree mst interface interface-id privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-425 78-11195-09...
  • Page 452 Command Description show spanning-tree Displays MST information for the specified interface. interface interface-id spanning-tree mst Configures an interface priority. port-priority spanning-tree mst priority Configures the switch priority for the specified spanning-tree instance. Catalyst 3550 Multilayer Switch Command Reference 2-426 78-11195-09...
  • Page 453: Spanning-Tree Mst Forward-Time

    Sets the interval between messages that the spanning tree receives from the root switch. spanning-tree mst max-hops Sets the number of hops in a region before the BPDU is discarded. Catalyst 3550 Multilayer Switch Command Reference 2-427 78-11195-09...
  • Page 454: Spanning-Tree Mst Hello-Time

    Sets the interval between messages that the spanning tree receives from the root switch. spanning-tree mst max-hops Sets the number of hops in a region before the BPDU is discarded. Catalyst 3550 Multilayer Switch Command Reference 2-428 78-11195-09...
  • Page 455: Spanning-Tree Mst Max-Age

    Sets the forward-delay time for all MST instances. spanning-tree mst hello-time Sets the interval between hello BPDUs sent by root switch configuration messages. spanning-tree mst max-hops Sets the number of hops in a region before the BPDU is discarded. Catalyst 3550 Multilayer Switch Command Reference 2-429 78-11195-09...
  • Page 456: Spanning-Tree Mst Max-Hops

    Sets the interval between hello BPDUs sent by root switch configuration messages. spanning-tree mst max-age Sets the interval between messages that the spanning tree receives from the root switch. Catalyst 3550 Multilayer Switch Command Reference 2-430 78-11195-09...
  • Page 457: Spanning-Tree Mst Port-Priority

    20 is placed into the forwarding state if a loop occurs: Switch(config)# interface fastethernet0/2 Switch(config-if)# spanning-tree mst 20 port-priority 0 You can verify your settings by entering the show spanning-tree mst interface interface-id privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-431 78-11195-09...
  • Page 458 Displays MST information for the specified interface. interface-id spanning-tree mst cost Sets the path cost for MST calculations. spanning-tree mst priority Sets the switch priority for the specified spanning-tree instance. Catalyst 3550 Multilayer Switch Command Reference 2-432 78-11195-09...
  • Page 459: Spanning-Tree Mst Priority

    Related Commands Command Description show spanning-tree mst instance-id Displays MST information for the specified interface. spanning-tree mst cost Sets the path cost for MST calculations. spanning-tree mst port-priority Configures an interface priority. Catalyst 3550 Multilayer Switch Command Reference 2-433 78-11195-09...
  • Page 460: Spanning-Tree Mst Root

    24576, the switch sets its own priority to 4096 less than the lowest switch priority. (4096 is the value of the least-significant bit of a 4-bit switch priority value.) Catalyst 3550 Multilayer Switch Command Reference 2-434...
  • Page 461: Spanning-Tree Mst Max-Hops

    Sets the interval between messages that the spanning tree receives from the root switch. spanning-tree mst max-hops Sets the number of hops in a region before the BPDU is discarded. Catalyst 3550 Multilayer Switch Command Reference 2-435 78-11195-09...
  • Page 462: Spanning-Tree Port-Priority

    This example shows how to increase the likelihood that the Fast Ethernet interface 0/2 will be put in the forwarding state if a loop occurs: Switch(config)# interface fastethernet0/2 Switch(config-if)# spanning-tree vlan 20 port-priority 0 You can verify your settings by entering the show spanning-tree interface interface-id privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-436 78-11195-09...
  • Page 463 Displays spanning-tree information for the specified interface. interface-id spanning-tree cost Sets the path cost for spanning-tree calculations. spanning-tree vlan priority Sets the switch priority for the specified spanning-tree instance. Catalyst 3550 Multilayer Switch Command Reference 2-437 78-11195-09...
  • Page 464: Spanning-Tree Portfast (Global Configuration)

    BPDUs. If a BPDU is received on a Port Fast-enabled port, the port loses its Port Fast-operational status and BPDU filtering is disabled. You can override the spanning-tree portfast bpdufilter default global configuration command by using the spanning-tree bdpufilter interface configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-438 78-11195-09...
  • Page 465: Spanning-Tree Portfast (Global Configuration)

    Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. spanning-tree bpdufilter Prevents a port from sending or receiving BPDUs.
  • Page 466: Spanning-Tree Portfast (Interface Configuration)

    Port Fast on a port that is not a trunk port by using the no spanning-tree portfast interface configuration command. The no spanning-tree portfast interface configuration command is the same as the spanning-tree portfast disable interface configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-440 78-11195-09...
  • Page 467: Spanning-Tree Portfast (Interface Configuration)

    Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. spanning-tree bpdufilter Prevents a port from sending or receiving bridge protocol data units (BPDUs).
  • Page 468: Spanning-Tree Stack-Port

    You must disable CSUF on the first interface before enabling it on a new interface. Examples This example shows how to enable CSUF on the GBIC interface: Switch(config)# interface gigabitethernet0/1 Switch(config-if)# spanning-tree stack-port You can verify your settings by entering the show running-config privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-442 78-11195-09...
  • Page 469 Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. spanning-tree uplinkfast Accelerates the choice of a new root port when a link or switch fails or when spanning tree reconfigures itself.
  • Page 470: Spanning-Tree Uplinkfast

    When spanning tree detects that the root port has failed, UplinkFast immediately switches over to an alternate root port, changing the new root port directly to FORWARDING state. During this time, a topology change notification is sent. Catalyst 3550 Multilayer Switch Command Reference 2-444 78-11195-09...
  • Page 471 Forces this switch to be the root switch. Catalyst 3550 Multilayer Switch Command Reference 2-445 78-11195-09...
  • Page 472: Spanning-Tree Vlan

    The forward-delay time is 15 seconds. The hello time is 2 seconds. The max-age is 20 seconds. The primary root switch priority is 24576. The secondary root switch priority is 28672. Command Modes Global configuration Catalyst 3550 Multilayer Switch Command Reference 2-446 78-11195-09...
  • Page 473 This example shows how to disable the STP on VLAN 5: Switch(config)# no spanning-tree vlan 5 You can verify your setting by entering the show spanning-tree privileged EXEC command. In this instance, VLAN 5 does not appear in the list. Catalyst 3550 Multilayer Switch Command Reference 2-447 78-11195-09...
  • Page 474 Enables the Port Fast feature on an interface in all its associated (interface configuration) VLANs. spanning-tree uplinkfast Enables the UplinkFast feature, which accelerates the choice of a new root port. Catalyst 3550 Multilayer Switch Command Reference 2-448 78-11195-09...
  • Page 475: Speed

    If the speed is set to auto, the switch negotiates with the device at the other end of the link for the speed setting and then forces the speed setting to the negotiated value. The duplex setting remains as configured on each end of the link, which could result in a duplex setting mismatch. Catalyst 3550 Multilayer Switch Command Reference 2-449 78-11195-09...
  • Page 476 Related Commands Command Description duplex Specifies the duplex mode of operation for Fast Ethernet and Gigabit Ethernet ports. show interfaces Displays the statistical information specific to all interfaces or to a specific interface Catalyst 3550 Multilayer Switch Command Reference 2-450 78-11195-09...
  • Page 477: Storm-Control

    Note For more information about storm control suppression levels, refer to the software configuration guide for this release. Catalyst 3550 Multilayer Switch Command Reference 2-451 78-11195-09...
  • Page 478 You can verify your settings by entering the show storm-control privileged EXEC command. Related Commands Command Description show storm-control Displays broadcast, multicast, or unicast storm control settings on all interfaces or on a specified interface. Catalyst 3550 Multilayer Switch Command Reference 2-452 78-11195-09...
  • Page 479: Switchcore

    This example shows how to enable QoS and enable the wirespeed-store: Switch(config)# mls qos Switch(config)# switchcore wirespeed-store You can verify your settings by entering the show controllers switch {resource-allocation priority | wirespeed-store} privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-453 78-11195-09...
  • Page 480 Chapter 2 Cisco IOS Commands switchcore Related Commands Command Description show controllers switch Displays the setting of the resource-allocation priority feature or resource-allocation priority the wirespeed-store. show controllers switch wirespeed-store Catalyst 3550 Multilayer Switch Command Reference 2-454 78-11195-09...
  • Page 481: Switchport

    This example shows how to cause an interface to cease operating as a Layer 2 port and become a Cisco-routed port. Switch(config-if)# no switchport This example shows how to cause the port interface to cease operating as a Cisco-routed port and convert to a Layer 2-switched interface: Switch(config-if)# switchport...
  • Page 482 (nonrouting) port, including port blocking and port protection settings. show running-config Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. Catalyst 3550 Multilayer Switch Command Reference 2-456...
  • Page 483: Switchport Access

    The port must be in access mode before the switchport access vlan command can take effect. An access port can be assigned to only one VLAN. The VMPS server (such as a Catalyst 6000 series switch) must be configured before a port is configured as dynamic. Catalyst 3550 Multilayer Switch Command Reference 2-457 78-11195-09...
  • Page 484 The software implements the VLAN Query Protocol (VQP) client, which can query a VMPS such as a Catalyst 6000 series switch. The Catalyst 3550 switches are not VMPS servers. The VMPS server must be configured before a port is configured as dynamic.
  • Page 485: Switchport Block

    You can verify your setting by entering the show interfaces interface-id switchport privileged EXEC command. Related Commands Command Description show interfaces switchport Displays the administrative and operational status of a switching (nonrouting) port, including port blocking and port protection settings. Catalyst 3550 Multilayer Switch Command Reference 2-459 78-11195-09...
  • Page 486: Switchport Broadcast

    Sets broadcast, multicast, or unicast storm control on an interface with the specified threshold level. switchport multicast Obsolete command. Replaced by the storm-control multicast interface configuration command. switchport unicast Obsolete command. Replaced by the storm-control unicast interface configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-460 78-11195-09...
  • Page 487: Switchport Mode

    When you enter dynamic auto mode, the interface converts the link to a trunk link if the neighboring interface is set to trunk or desirable mode. Catalyst 3550 Multilayer Switch Command Reference 2-461 78-11195-09...
  • Page 488 Examples This example shows how to configure a port for access mode: Switch(config-if)# switchport mode access This example shows how set the interface to dynamic desirable mode: Switch(config-if)# switchport mode dynamic desirable Catalyst 3550 Multilayer Switch Command Reference 2-462 78-11195-09...
  • Page 489 (nonrouting) port, including port blocking and port protection settings. switchport access Configures a port as a static-access or dynamic-access port. switchport trunk Configures the trunk characteristics when an interface is in trunking mode. Catalyst 3550 Multilayer Switch Command Reference 2-463 78-11195-09...
  • Page 490: Switchport Multicast

    Sets broadcast, multicast, or unicast storm control on an interface with the specified threshold level. switchport broadcast Obsolete command. Replaced by the storm-control broadcast interface configuration command. switchport unicast Obsolete command. Replaced by the storm-control unicast interface configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-464 78-11195-09...
  • Page 491: Switchport Nonegotiate

    If trunking is required on a GigaStack GBIC where both ports are in use, use the switchport mode trunk and switchport nonegotiate interface configuration commands on both GBIC interfaces to cause the interfaces to become trunks. Catalyst 3550 Multilayer Switch Command Reference 2-465 78-11195-09...
  • Page 492 Description show interfaces switchport Displays the administrative and operational status of a switching (nonrouting) port, including port blocking and port protection settings. switchport mode Configures the VLAN membership mode of a port. Catalyst 3550 Multilayer Switch Command Reference 2-466 78-11195-09...
  • Page 493: Switchport Port-Security

    If no per-VLAN maximum value is entered, the default value is used. violation (Optional) Set the security violation mode or the action to be taken if port security is violated. The default is shutdown. Catalyst 3550 Multilayer Switch Command Reference 2-467 78-11195-09...
  • Page 494 The maximum number of available MAC addresses on a secure port or VLAN is determined by the active Switch Database Management (SDM) template. Refer to the software configuration guide for more information about configuring an SDM template. Catalyst 3550 Multilayer Switch Command Reference 2-468 78-11195-09...
  • Page 495 VLAN are learned as dynamic secure addresses while all addresses seen on the access VLAN (to which the port belongs) are learned as sticky secure addresses. The switch does not support port security aging of sticky secure MAC addresses. • Catalyst 3550 Multilayer Switch Command Reference 2-469 78-11195-09...
  • Page 496 You can verify the settings for all secure ports or the specified port by using the show port-security privileged EXEC command. Related Commands Command Description clear port-security Deletes from the MAC address table a specific secure address or all the secure addresses on an interface. Catalyst 3550 Multilayer Switch Command Reference 2-470 78-11195-09...
  • Page 497: Switchport Port-Security Aging

    To allow continuous access to a limited number of secure addresses, set the aging type as inactivity. This removes the secure address when it become inactive, and other addresses can become secure. Catalyst 3550 Multilayer Switch Command Reference 2-471 78-11195-09...
  • Page 498 Displays the port security settings defined for the port. switchport port-security Enables port security on a port, restricts the use of the port to a user-defined group of stations, and configures secure MAC addresses. Catalyst 3550 Multilayer Switch Command Reference 2-472 78-11195-09...
  • Page 499: Switchport Priority Extend

    The none keyword was removed and was replaced by the trust keyword. Usage Guidelines In Cisco IOS Release 12.1(13)EA1 or later, the trust keyword replaces the none keyword. To instruct the IP Phone to not trust the priority, you can use the no switchport priority extend or the switchport priority extend cos 0 interface configuration command.
  • Page 500 Chapter 2 Cisco IOS Commands switchport priority extend Related Commands Command Description show interfaces Displays the administrative and operational status of a switching (nonrouting) port. switchport voice vlan Configures the voice VLAN on the port. Catalyst 3550 Multilayer Switch Command Reference 2-474 78-11195-09...
  • Page 501: Switchport Protected

    Displays the administrative and operational status of a switching (nonrouting) switchport port, including port blocking and port protection settings. switchport block Prevents unknown multicast or unicast traffic on the interface. Catalyst 3550 Multilayer Switch Command Reference 2-475 78-11195-09...
  • Page 502: Switchport Trunk

    You can add extended-range VLANs to the allowed VLAN list, but not to the pruning-eligible VLAN list. Separate nonconsecutive VLAN IDs with a comma; use a hyphen to designate a range of IDs. Catalyst 3550 Multilayer Switch Command Reference 2-476 78-11195-09...
  • Page 503 ISL is the selected format. The no form of the command resets the trunk encapsulation format to the default. The no form of the encapsulation command resets the encapsulation format to the default. • Catalyst 3550 Multilayer Switch Command Reference 2-477 78-11195-09...
  • Page 504 VLAN trunk port by removing VLAN 1 from the allowed list. This is known as VLAN 1 minimization. VLAN 1 minimization disables VLAN 1 (the default VLAN on all Cisco switch trunk ports) on an individual VLAN trunk link. As a result, no user traffic, including spanning-tree advertisements, is sent or received on VLAN 1.
  • Page 505 Description show interfaces switchport Displays the administrative and operational status of a switching (nonrouting) port, including port blocking and port protection settings. switchport mode Configures the VLAN membership mode of a port. Catalyst 3550 Multilayer Switch Command Reference 2-479 78-11195-09...
  • Page 506: Switchport Unicast

    Sets broadcast, multicast, or unicast storm control on an interface with the specified threshold level. switchport broadcast Obsolete command. Replaced by the storm-control broadcast interface configuration command. switchport multicast Obsolete command. Replaced by the storm-control multicast interface configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-480 78-11195-09...
  • Page 507: Switchport Voice Vlan

    The telephone uses priority tagging and uses VLAN 0 (the native VLAN). By default, the Cisco IP phone forwards the voice traffic with an 802.1P priority of 5. none The telephone is not instructed through the CLI about the voice VLAN. The telephone uses the configuration from the telephone key pad.
  • Page 508 Displays the administrative and operational status of a switching (nonrouting) port. switchport priority extend Determines how the device connected to the specified port handles priority traffic received on its incoming port. Catalyst 3550 Multilayer Switch Command Reference 2-482 78-11195-09...
  • Page 509: System Mtu

    This example shows the response when you try to set a Fast Ethernet switch to an out-of-range number: Switch(config)# system mtu 1580 % Invalid input detected at '^' marker. You can verify your settings by entering the show system mtu privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-483 78-11195-09...
  • Page 510 Chapter 2 Cisco IOS Commands system mtu Related Commands Command Description show system mtu Displays the maximum packet size set for the switch. Catalyst 3550 Multilayer Switch Command Reference 2-484 78-11195-09...
  • Page 511: Traceroute Mac

    This command was first introduced. Usage Guidelines For Layer 2 traceroute to functional properly, Cisco Discovery Protocol (CDP) must be enabled on all the switches in the network. Do not disable CDP. When the switch detects a device in the Layer 2 path that does not support Layer 2 traceroute, the switch continues to send Layer 2 trace queries and lets them time out.
  • Page 512 This example shows the Layer 2 path when the switch cannot find the destination port for the source MAC address: Switch# traceroute mac 0000.0011.1111 0000.0201.0201 Error:Source Mac address not found. Layer2 trace aborted. Catalyst 3550 Multilayer Switch Command Reference 2-486 78-11195-09...
  • Page 513 Related Commands Command Description traceroute mac ip Displays the Layer 2 path taken by the packets from the specified source IP address or hostname to the specified destination IP address or hostname. Catalyst 3550 Multilayer Switch Command Reference 2-487 78-11195-09...
  • Page 514: Traceroute Mac Ip

    This command was first introduced. Usage Guidelines For Layer 2 traceroute to functional properly, Cisco Discovery Protocol (CDP) must be enabled on all the switches in the network. Do not disable CDP. When the switch detects an device in the Layer 2 path that does not support Layer 2 traceroute, the switch continues to send Layer 2 trace queries and lets them time out.
  • Page 515 Arp failed for destination 2.2.77.77. Layer2 trace aborted. Related Commands Command Description traceroute mac Displays the Layer 2 path taken by the packets from the specified source MAC address to the specified destination MAC address. Catalyst 3550 Multilayer Switch Command Reference 2-489 78-11195-09...
  • Page 516: Trust

    Instead, you can use the police policy-map class configuration command to mark down (reduce) the DSCP value at the egress interface. • Access control list (ACL) classification. Per-port per-VLAN classification. • Catalyst 3550 Multilayer Switch Command Reference 2-490 78-11195-09...
  • Page 517 Defines a policer for classified traffic. policy-map Creates or modifies a policy map that can be attached to multiple interfaces to specify a service policy. show policy-map Displays QoS policy maps. Catalyst 3550 Multilayer Switch Command Reference 2-491 78-11195-09...
  • Page 518: Udld

    • The shutdown and no shutdown interface configuration commands • The no udld enable global configuration command followed by the udld {aggressive | enable} • global configuration command to re-enable UDLD globally Catalyst 3550 Multilayer Switch Command Reference 2-492 78-11195-09...
  • Page 519 Enables UDLD on an individual interface or prevents a fiber-optic interface from being enabled by the udld global configuration command. udld reset Resets all interfaces shut down by UDLD and permits traffic to again pass through. Catalyst 3550 Multilayer Switch Command Reference 2-493 78-11195-09...
  • Page 520: Udld Port

    Use the no form on fiber-optic ports to remove this setting and to return control of UDLD enabling to the udld global configuration command or to disable UDLD on nonfiber-optic ports. Catalyst 3550 Multilayer Switch Command Reference 2-494 78-11195-09...
  • Page 521 Displays the running configuration on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. show udld Displays UDLD administrative and operational status for all ports or the specified port.
  • Page 522: Udld Reset

    Displays the running configuration on the switch. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for Release 12.1 > Cisco IOS File Management Commands > Configuration File Commands. show udld Displays UDLD administrative and operational status for all ports or the specified port.
  • Page 523: Vlan (Global Configuration)

    VTP mode and the VLAN configuration for the first 1005 VLANs use the VLAN database information. • If the image on the switch or the configuration file is earlier than Cisco IOS Release 12.1(9)EA1, the switch reboots with information in the VLAN database. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 524: Vlan (Global Configuration)

    TrBRF media type if the VTP v2 mode is enabled. mtu mtu-size: specifies the maximum transmission unit (MTU) (packet size in bytes). Valid values • are from 1500 to 18190. The default is 1500 bytes. Catalyst 3550 Multilayer Switch Command Reference 2-498 78-11195-09...
  • Page 525 VLAN is translationally bridged. Translational VLANs translate FDDI or Token Ring to Ethernet, for example. Valid values are from 0 to 1005. If no value is specified, 0 (no transitional bridging) is assumed. Catalyst 3550 Multilayer Switch Command Reference 2-499 78-11195-09...
  • Page 526 VLAN ID. Only one backup concentrator relay function (CRF) can be enabled. VTP v2 mode is enabled, and you Do not specify a backup CRF. are configuring VLANs other than TrCRF media type. Catalyst 3550 Multilayer Switch Command Reference 2-500 78-11195-09...
  • Page 527 VLAN in the switch startup configuration file: Switch(config)# vtp mode transparent Switch(config)# vlan 2000 Switch(config-vlan)# end Switch# copy running-config startup config You can verify your setting by entering the show vlan privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-501 78-11195-09...
  • Page 528 Displays the parameters for all configured VLANs or one VLAN (if the VLAN ID or name is specified) in the administrative domain. vlan (VLAN Configures normal-range VLANs in the VLAN database. configuration) Catalyst 3550 Multilayer Switch Command Reference 2-502 78-11195-09...
  • Page 529: Vlan (Vlan Configuration)

    VLAN in FDDI-NET, Token Ring-NET, and TrBRF VLANs. Valid bridge numbers are from 0 to 15. The type keyword applies only to TrCRF VLANs and is one of these: srb (source-route bridging) • • srt (source-route transparent) bridging VLAN Catalyst 3550 Multilayer Switch Command Reference 2-503 78-11195-09...
  • Page 530: Vlan (Vlan Configuration)

    Ring to Ethernet, for example. Valid values are from 0 to 1005. Zero is assumed if no value is specified. Table 2-31 shows the valid syntax options for different media types. Catalyst 3550 Multilayer Switch Command Reference 2-504 78-11195-09...
  • Page 531 VLAN ID. Only one backup concentrator relay function (CRF) can be enabled. VTP v2 mode is enabled, and you Do not specify a backup CRF. are configuring VLANs other than TrCRF media type. Catalyst 3550 Multilayer Switch Command Reference 2-505 78-11195-09...
  • Page 532 The STP type is ieee for FDDI-NET and ibm for Token Ring-NET VLANs. For FDDI and Token Ring VLANs, the default is no type specified. The tb-vlan1-id and tb-vlan2-id variables are zero (no translational bridging). Command Modes VLAN configuration Catalyst 3550 Multilayer Switch Command Reference 2-506 78-11195-09...
  • Page 533 VTP mode and the VLAN configuration for the first 1005 VLANs use VLAN database information. If the image on the switch or the configuration file is earlier than Cisco IOS Release 12.1(9)EA1, • the switch reboots with information in the VLAN database.
  • Page 534 Displays the parameters for all configured VLANs or one VLAN (if the VLAN ID or name is specified) in the administrative domain. vlan (global Enters config-vlan mode for configuring normal-range and extended-range configuration) VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-508 78-11195-09...
  • Page 535: Vlan Access-Map

    You can use the no vlan access-map name [number] command with a sequence number to delete a single entry. In global configuration mode, use the vlan filter interface configuration command to apply the map to one or more VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-509 78-11195-09...
  • Page 536 Sets the VLAN map to match packets against one or more access configuration)) lists. show vlan access-map Displays information about a particular VLAN access map or all VLAN access maps. vlan filter Applies the VLAN access map to one or more VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-510 78-11195-09...
  • Page 537: Vlan Database

    VLAN. For more information, see the vlan (VLAN configuration) command. • vtp: accesses subcommands to perform VTP administrative functions. For more information, see the vtp (VLAN configuration) command. Catalyst 3550 Multilayer Switch Command Reference 2-511 78-11195-09...
  • Page 538 VLAN 802.10 Id: 100001 State: Operational MTU: 1500 Translational Bridged VLAN: 1002 Translational Bridged VLAN: 1003 VLAN ISL Id: 2 Name: VLAN0002 Media Type: Ethernet VLAN 802.10 Id: 100002 State: Operational MTU: 1500 Catalyst 3550 Multilayer Switch Command Reference 2-512 78-11195-09...
  • Page 539 This is an example of output from the show current 20 command. It displays only VLAN 20 of the current database. Switch(vlan)# show current 20 VLAN ISL Id: 20 Name: VLAN0020 Media Type: Ethernet VLAN 802.10 Id: 100020 State: Operational MTU: 1500 Catalyst 3550 Multilayer Switch Command Reference 2-513 78-11195-09...
  • Page 540 Displays the parameters for all configured VLANs in the administrative domain. shutdown vlan Shuts down (suspends) local traffic on the specified VLAN. vlan (global Enters config-vlan mode for configuring normal-range and extended-range configuration) VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-514 78-11195-09...
  • Page 541: Vlan Dot1Q Tag Native

    Switch (config)# vlan dot1q tag native Switch (config)# end Switch# show vlan dot1q tag native dot1q native vlan tagging is enabled Related Commands Command Description show vlan dot1q tag native Displays 802.1Q native VLAN tagging status. Catalyst 3550 Multilayer Switch Command Reference 2-515 78-11195-09...
  • Page 542: Vlan Filter

    This example shows how to delete VLAN map entry mac1 from VLAN 20: Switch(config)# no vlan filter map1 vlan-list 20 You can verify your settings by entering the show vlan filter privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-516 78-11195-09...
  • Page 543 Displays information about a particular VLAN access map or all VLAN access maps. show vlan filter Displays information about all VLAN filters or about a particular VLAN or VLAN access map. vlan access-map Creates a VLAN map entry for VLAN packet filtering. Catalyst 3550 Multilayer Switch Command Reference 2-517 78-11195-09...
  • Page 544: Vmps Reconfirm (Privileged Exec)

    Related Commands Command Description show vmps Displays VQP and VMPS information. vmps reconfirm (global Changes the reconfirmation interval for the VLAN Query Protocol (VQP) configuration) client. Catalyst 3550 Multilayer Switch Command Reference 2-518 78-11195-09...
  • Page 545: Vmps Reconfirm (Global Configuration)

    Reconfirm Interval row. Related Commands Command Description show vmps Displays VQP and VMPS information. vmps reconfirm (privileged EXEC) Sends VQP queries to reconfirm all dynamic VLAN assignments with the VMPS. Catalyst 3550 Multilayer Switch Command Reference 2-519 78-11195-09...
  • Page 546: Vmps Retry

    You can verify your setting by entering the show vmps privileged EXEC command and examining information in the Server Retry Count row. Related Commands Command Description show vmps Displays VQP and VMPS information. Catalyst 3550 Multilayer Switch Command Reference 2-520 78-11195-09...
  • Page 547: Vmps Server

    This example shows how to configure the server with IP address 191.10.49.20 as the primary VMPS server. The servers with IP addresses 191.10.49.21 and 191.10.49.22 are configured as secondary servers: Switch(config)# vmps server 191.10.49.20 primary Switch(config)# vmps server 191.10.49.21 Switch(config)# vmps server 191.10.49.22 Catalyst 3550 Multilayer Switch Command Reference 2-521 78-11195-09...
  • Page 548 You can verify your setting by entering the show vmps privileged EXEC command and examining information in the VMPS Domain Server row. Related Commands Command Description show vmps Displays VQP and VMPS information. Catalyst 3550 Multilayer Switch Command Reference 2-522 78-11195-09...
  • Page 549: Vtp (Global Configuration)

    VTP administrative domain for the switch. The domain name is case sensitive. file filename Specify the Cisco IOS file system file where the VTP VLAN configuration is stored. interface name Specify the name of the interface providing the VTP ID updated for this device.
  • Page 550: Vtp (Global Configuration)

    • If the image on the switch or the configuration file is earlier than Cisco IOS Release 12.1(9)EA1, the switch reboots using the information in the VLAN database. The vtp file filename cannot be used to load a new database; it renames only the file in which the existing database is stored.
  • Page 551 If you are configuring a Token Ring bridge relay function (TrBRF) or Token Ring concentrator relay function (TrCRF) VLAN media type, you must use version 2. • If you are configuring a Token Ring or Token Ring-NET VLAN media type, you must use version 1. Catalyst 3550 Multilayer Switch Command Reference 2-525 78-11195-09...
  • Page 552 Command Description show vtp status Displays the VTP statistics for the switch and general information about the VTP management domain status. vtp (VLAN Configures VTP domain-name, password, pruning, version, and mode. configuration) Catalyst 3550 Multilayer Switch Command Reference 2-526 78-11195-09...
  • Page 553: Vtp (Privileged Exec)

    Only VLANs in the pruning-eligible list can be pruned. Pruning is supported with VTP version 1 and version 2. Toggling the version 2 (v2) mode state modifies parameters of certain default VLANs. Catalyst 3550 Multilayer Switch Command Reference 2-527 78-11195-09...
  • Page 554: Vtp (Privileged Exec)

    Configures the VTP filename, interface, domain-name, and mode, which can configuration) be saved in the switch configuration file. vtp (VLAN Configures all VTP characteristics but cannot be saved to the switch configuration) configuration file. Catalyst 3550 Multilayer Switch Command Reference 2-528 78-11195-09...
  • Page 555: Vtp (Vlan Configuration)

    Defaults The default mode is server mode. No domain name is defined. No password is configured. Catalyst 3550 Multilayer Switch Command Reference 2-529 78-11195-09...
  • Page 556: Vtp (Vlan Configuration)

    After the switch leaves the no-management-domain state, it can never be configured to reenter it until you clear the nonvolatile RAM (NVRAM) and reload the software. Catalyst 3550 Multilayer Switch Command Reference 2-530 78-11195-09...
  • Page 557 Setting device to VTP TRANSPARENT mode. This example shows how to set the administrative domain for the switch: Switch(vlan)# vtp domain OurDomainName Changing VTP domain name from cisco to OurDomainName This example shows how to configure the VTP domain password: Switch(vlan)# vtp password private Setting device VLAN database password to private.
  • Page 558 Displays the VTP statistics for the switch and general information about the VTP management domain status. switchport trunk Configures the VLAN pruning-eligible list for ports in trunking mode. pruning vtp (global Configures the VTP filename, interface, domain-name, and mode. configuration) Catalyst 3550 Multilayer Switch Command Reference 2-532 78-11195-09...
  • Page 559: Wrr-Queue Bandwidth

    1/(1+2+3+4), 2/(1+2+3+4), 3/(1+2+3+4), and 4/(1+2+3+4), which is 1/10, 1/5, 3/10, and 2/5 for queues 1, 2, 3, and 4. Switch(config)# interface gigabitethernet0/1 Switch(config-if)# wrr-queue bandwidth 1 2 3 4 Catalyst 3550 Multilayer Switch Command Reference 2-533 78-11195-09...
  • Page 560 Displays quality of service (QoS) information. wrr-queue cos-map Maps assigned class of service (CoS) values to select one of the egress queues. wrr-queue queue-limit Configures the sizes of the egress queues on Gigabit-capable Ethernet ports. Catalyst 3550 Multilayer Switch Command Reference 2-534 78-11195-09...
  • Page 561: Wrr-Queue Cos-Map

    You can use this command to distribute traffic into different queues, where each queue is configured with different weighted round robin (WRR) and Weighted Random Early Detection (WRED) parameters. You enable the expedite queue by using the priority-queue out interface configuration command. Catalyst 3550 Multilayer Switch Command Reference 2-535 78-11195-09...
  • Page 562 Displays the queueing strategy (WRR, priority queueing), the weights corresponding to the queues, and the CoS-to-egress-queue map. wrr-queue dscp-map Maps DSCP values to the tail-drop or WRED thresholds of the egress queues. Catalyst 3550 Multilayer Switch Command Reference 2-536 78-11195-09...
  • Page 563: Wrr-Queue Dscp-Map

    Switch(config-if)# wrr-queue dscp-map 1 8 9 Switch(config-if)# wrr-queue dscp-map 2 10 11 12 13 14 You can verify your settings by entering the show running-config or the show mls qos interface interface-id privileged EXEC command. Catalyst 3550 Multilayer Switch Command Reference 2-537 78-11195-09...
  • Page 564 Enables WRED and assigns two WRED threshold values to an egress max-threshold queue of a Gigabit-capable Ethernet port. wrr-queue threshold Assigns tail-drop threshold percentages to an egress queue of a Gigabit-capable Ethernet port. Catalyst 3550 Multilayer Switch Command Reference 2-538 78-11195-09...
  • Page 565: Wrr-Queue Min-Reserve

    You can verify your settings by entering the show mls qos interface buffers privileged EXEC command. Related Commands Command Description mls qos min-reserve Configures the minimum-reserve levels on 10/100 Ethernet ports. show mls qos interface Displays quality of service (QoS) information. Catalyst 3550 Multilayer Switch Command Reference 2-539 78-11195-09...
  • Page 566: Wrr-Queue Queue-Limit

    Displays QoS information. wrr-queue bandwidth Assigns weighted round robin (WRR) weights to the egress queues. wrr-queue min-reserve Configures the sizes of the minimum-reserve threshold values of the queues on 10/100 Ethernet ports. Catalyst 3550 Multilayer Switch Command Reference 2-540 78-11195-09...
  • Page 567: Wrr-Queue Random-Detect Max-Threshold

    WRED or tail-drop thresholds can be configured. When you enter the no wrr-queue random-detect max-threshold queue-id command, tail drop is enabled with the maximum threshold values set to 100 percent. Catalyst 3550 Multilayer Switch Command Reference 2-541 78-11195-09...
  • Page 568 Displays QoS information. wrr-queue dscp-map Maps DSCP values to the tail-drop or WRED thresholds of the egress queues. wrr-queue queue-limit Configures the sizes of the egress queues on Gigabit-capable Ethernet ports. Catalyst 3550 Multilayer Switch Command Reference 2-542 78-11195-09...
  • Page 569: Wrr-Queue Threshold

    You configure the DSCP-to-threshold map by using the wrr-queue dscp-map interface configuration command on the ingress interface. The wrr-queue threshold and the wrr-queue random-detect threshold commands are mutually exclusive, and only tail-drop or Weighted Random Early Detection (WRED) thresholds can be configured. Catalyst 3550 Multilayer Switch Command Reference 2-543 78-11195-09...
  • Page 570 Displays QoS information. wrr-queue dscp-map Maps DSCP values to the tail-drop or WRED thresholds of the egress queues. wrr-queue queue-limit Configures the sizes of the egress queues on Gigabit-capable Ethernet ports. Catalyst 3550 Multilayer Switch Command Reference 2-544 78-11195-09...
  • Page 571: Appendix

    You gain access to the boot loader command line if the switch is set to manually boot, if an error occurs during power-on self test (POST) DRAM testing, or if an error occurs while loading the operating system (a corrupted Cisco IOS image). You can also access the boot loader if you have lost or forgotten the switch password.
  • Page 572: Boot

    After entering this command, you are prompted to start the setup program. Related Commands Command Description Sets the BOOT environment variable to boot a specific image when the BOOT keyword is appended to the command. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 573: Cat

    3049472 total_image_file_size: 4551168 image_feature: LAYER_3|MIN_DRAM_MEG=64 image_family: C3550 info_end: BAUD=57600 MANUAL_BOOT=no Related Commands Command Description more Displays the contents of one or more files. type Displays the contents of one or more files. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 574: Copy

    File "flash:test1.text" successfully copied to "flash:test4.text" You can verify that the file was copied by entering the dir filesystem: boot loader command. Related Commands Command Description delete Deletes one or more files from the specified file system. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 575 File "flash:test2.text" deleted You can verify that the files were deleted by entering the dir flash: boot loader command. Related Commands Command Description copy Copies a file from a source to a destination. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 576: Dir

    Mar 01 1993 23:11:42 html -rwx 1037 Mar 01 1993 00:01:11 config.text -rwx 1099 Mar 01 1993 01:14:05 homepage.htm -rwx Mar 01 1993 00:01:39 system_env_vars drwx 1993 23:22:03 c3550-i5q3l2-mz.121-0.64.EA1 15998976 bytes total (6397440 bytes free) Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 577 • w—writable • x—executable • 1644045 Size of the file. <date> Last modification date. env_vars Filename. Related Commands Command Description mkdir Creates one or more directories. rmdir Removes one or more directories. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 578: Flash_Init

    During the normal boot process, the Flash file system is automatically initialized. Use this command to manually initialize the Flash file system. For example, you use this command during the recovery procedure for a lost or forgotten password. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 579: Format

    Boot loader Command History Release Modification 12.1(4)EA1 This command was first introduced. Usage Guidelines Caution Use this command with care; it destroys all data on the file system and renders your system unusable. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 580: Fsck

    To stop an in-progress file system consistency check, disconnect the switch power and then reconnect the power. Examples This example shows how to perform an extensive file system check on Flash memory: switch: fsck -test flash: Catalyst 3550 Multilayer Switch Command Reference A-10 78-11195-09...
  • Page 581: Help

    Command Modes Boot loader Command History Release Modification 12.1(4)EA1 This command was first introduced. Usage Guidelines You can also use the question mark (?) to display a list of available boot loader commands. Catalyst 3550 Multilayer Switch Command Reference A-11 78-11195-09...
  • Page 582: Load_Helper

    Release Modification 12.1(4)EA1 This command was first introduced. Usage Guidelines The load_helper command searches for loadable files only if the HELPER environment variable is set. Filenames and directory names are case sensitive. Catalyst 3550 Multilayer Switch Command Reference A-12 78-11195-09...
  • Page 583: Memory

    Text entry. Data Beginning and ending address of the data segment storage area. Beginning and ending address of the block started by symbol (Bss) storage area. It is initialized to zero. Catalyst 3550 Multilayer Switch Command Reference A-13 78-11195-09...
  • Page 584 Beginning and ending address of the area in memory allocated to the software to store automatic variables, return addresses, and so forth. Heap Beginning and ending address of the area in memory that memory is dynamically allocated to and freed from. Catalyst 3550 Multilayer Switch Command Reference A-14 78-11195-09...
  • Page 585: Mkdir

    You can verify that the directory was created by entering the dir filesystem: boot loader command. Related Commands Command Description Displays a list of files and directories on the specified file system. rmdir Removes one or more directories from the specified file system. Catalyst 3550 Multilayer Switch Command Reference A-15 78-11195-09...
  • Page 586: More

    3049472 total_image_file_size: 4551168 image_feature: LAYER_3|MIN_DRAM_MEG=64 image_family: C3550 info_end: BAUD=57600 MANUAL_BOOT=no Related Commands Command Description Displays the contents of one or more files. type Displays the contents of one or more files. Catalyst 3550 Multilayer Switch Command Reference A-16 78-11195-09...
  • Page 587: Rename

    You can verify that the file was renamed by entering the dir filesystem: boot loader command. Related Commands Command Description copy Copies a file from a source to a destination. Catalyst 3550 Multilayer Switch Command Reference A-17 78-11195-09...
  • Page 588: Reset

    This example shows how to reset the system: switch: reset Are you sure you want to reset the system (y/n)?y System resetting... Related Commands Command Description boot Loads and boots an executable image and enters the command-line interface. Catalyst 3550 Multilayer Switch Command Reference A-18 78-11195-09...
  • Page 589: Rmdir

    You can verify that the directory was deleted by entering the dir filesystem: boot loader command. Related Commands Command Description Displays a list of files and directories on the specified file system. mkdir Creates one or more new directories on the specified file system. Catalyst 3550 Multilayer Switch Command Reference A-19 78-11195-09...
  • Page 590: Set

    The range is from 4096 to 524288 bytes. BAUD rate—The rate in bits per second (bps) used for the console. The Cisco IOS software inherits the baud rate setting from the boot loader and continues to use this value unless the configuration file specifies another setting.
  • Page 591 This variable is used only for internal development and testing. HELPER_CONFIG_FILE filesystem:/file-url—The name of the configuration file to be used by the Cisco IOS helper image. If this is not set, the file specified by the CONFIG_FILE environment variable is used by all versions of Cisco IOS that are loaded, including the helper image.
  • Page 592 PS1 loader: loader: You can verify your setting by using the set boot loader command. Related Commands Command Description unset Resets one or more environment variables to its previous setting. Catalyst 3550 Multilayer Switch Command Reference A-22 78-11195-09...
  • Page 593: Type

    3049472 total_image_file_size: 4551168 image_feature: LAYER_3|MIN_DRAM_MEG=64 image_family: C3550 info_end: BAUD=57600 MANUAL_BOOT=no Related Commands Command Description Displays the contents of one or more files. more Displays the contents of one or more files. Catalyst 3550 Multilayer Switch Command Reference A-23 78-11195-09...
  • Page 594: Unset

    HELPER_CONFIG_FILE—Resets the name of the configuration file to be used by the Cisco IOS helper image. If this is not set, the file specified by the CONFIG_FILE environment variable is used by all versions of Cisco IOS that are loaded, including the helper image. This variable is used only for internal development and testing.
  • Page 595 The HELPER_CONFIG_FILE environment variable can also be reset by using the no boot helper-config-file global configuration command. Examples This example shows how to reset the prompt string to its previous setting: switch: unset PS1 switch: Related Commands Command Description Sets or displays environment variables. Catalyst 3550 Multilayer Switch Command Reference A-25 78-11195-09...
  • Page 596: Version

    12.1(4)EA1 This command was first introduced. Examples This example shows how to display the boot loader version: switch: version C3550 Boot Loader (C3550-HBOOT-M) Version 12.1(4)EA1 Compiled Wed 21-Feb-01 14:58 by devgoyal switch: Catalyst 3550 Multilayer Switch Command Reference A-26 78-11195-09...
  • Page 597: Appendix

    For this reason, use the debug commands only to troubleshoot specific problems or during troubleshooting sessions with Cisco technical support staff. It is best to use the debug commands during periods of lower network traffic and fewer users. Debugging during these periods decreases the likelihood that increased debug command processing overhead will affect system use.
  • Page 598: Debug Acltcam

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 599: Debug Autoqos

    4d22h: mls qos trust cos 4d22h: wrr-queue bandwidth 20 1 80 0 4d22h: wrr-queue min-reserve 1 5 4d22h: wrr-queue min-reserve 2 6 4d22h: wrr-queue min-reserve 3 7 4d22h: wrr-queue min-reserve 4 8 4d22h: no wrr-queue cos-map Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 600 Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference For IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 601: Debug Cluster

    Defaults Debugging is disabled. Command Modes Privileged EXEC Command History Release Modification 12.1(4)EA1 This command was first introduced. Usage Guidelines The undebug cluster command is the same as the no debug cluster command. Catalyst 3550 Multilayer Switch Command Reference 78-11195-09...
  • Page 602 Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show cluster Displays the cluster status and a summary of the cluster to which the switch belongs.
  • Page 603: Debug Cpu-Interface

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 604: Debug Dot1X

    Displays information about the types of debugging that are enabled. For syntax information, refer to the Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show dot1x Displays 802.1X statistics, administrative status, and operational status for the switch or for the specified interface.
  • Page 605: Debug Etherchannel

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show etherchannel Displays EtherChannel information for the channel.
  • Page 606: Debug Ethernet-Controller Ram-Access

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 607: Debug Fallback-Bridging

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 608: Debug Gigastack

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 609: Debug Ilpower Controller

    Power Controller register reading. Use the no form of this command to disable debugging output. debug ilpower controller no debug ilpower controller This command is available only on the Catalyst 3550-24PWR switch. Syntax Description This command has no keywords or arguments.
  • Page 610: Debug Ilpower Event

    Use the no form of this command to disable debugging output. debug ilpower event no debug ilpower event This command is available only on the Catalyst 3550-24PWR switch. Syntax Description This command has no keywords or arguments.
  • Page 611: Debug Ip Dhcp Snooping

    The undebug ip dhcp snooping command is the same as the no ip debug dhcp snooping command. Related Commands Command Description show ip dhcp snooping Displays the DHCP snooping configuration. show ip dhcp snooping Displays the DHCP snooping binding information. binding Catalyst 3550 Multilayer Switch Command Reference B-15 78-11195-09...
  • Page 612: Debug Ip Igmp Filter

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 613: Debug Ip Igmp Max-Groups

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 614: Debug L3Multicast

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 615: Debug L3Tcam

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 616: Debug L3Unicast

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 617: Debug Mac-Manager

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 618: Debug Mac-Notification

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show mac Displays the MAC address notification information for all interfaces or the address-table specified interface.
  • Page 619: Debug Met

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 620: Debug Mvrdbg

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show mvr Displays the current MVR configuration.
  • Page 621: Debug Pagp

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show pagp Displays PAgP channel-group information.
  • Page 622: Debug Pbr

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 623: Debug Pm

    Debugging is disabled. Command Modes Privileged EXEC Command History Release Modification 12.1(4)EA1 This command was first introduced. Usage Guidelines The undebug pm command is the same as the no debug pm command. Catalyst 3550 Multilayer Switch Command Reference B-27 78-11195-09...
  • Page 624 Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. Catalyst 3550 Multilayer Switch Command Reference...
  • Page 625: Debug Port-Security

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show port-security Displays port-security settings for an interface or for the switch.
  • Page 626: Debug Span-Session

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show monitor Displays SPAN session information.
  • Page 627: Debug Spanning-Tree

    Command History Release Modification 12.1(4)EA1 This command was first introduced. 12.1(9)EA1 The mstp and csuf keywords were added. Usage Guidelines The undebug spanning-tree command is the same as the no debug spanning-tree command. Catalyst 3550 Multilayer Switch Command Reference B-31 78-11195-09...
  • Page 628 Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show spanning-tree Displays spanning-tree state information.
  • Page 629: Debug Spanning-Tree Backbonefast

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show spanning-tree Displays spanning-tree state information.
  • Page 630: Debug Spanning-Tree Bpdu

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show spanning-tree Displays spanning-tree state information.
  • Page 631: Debug Spanning-Tree Bpdu-Opt

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show spanning-tree Displays spanning-tree state information.
  • Page 632: Debug Spanning-Tree Mstp

    Debug topology change notification events. timers Debug the MSTP timers for start, stop, and expire events. Defaults Debugging is disabled. Command Modes Privileged EXEC Command History Release Modification 12.1(9)EA1 This command was first introduced. Catalyst 3550 Multilayer Switch Command Reference B-36 78-11195-09...
  • Page 633 Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show spanning-tree Displays spanning-tree state information.
  • Page 634: Debug Spanning-Tree Switch

    The helper keyword was added. Usage Guidelines This command can be entered only from the switch console. The undebug spanning-tree switch command is the same as the no debug spanning-tree switch command. Catalyst 3550 Multilayer Switch Command Reference B-38 78-11195-09...
  • Page 635 Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show spanning-tree Displays spanning-tree state information.
  • Page 636: Debug Spanning-Tree Uplinkfast

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show spanning-tree Displays spanning-tree state information.
  • Page 637: Debug Sw-Vlan

    Debug messages generated when the CLI is in config-vlan mode. events Debug VLAN manager events. Debug VLAN manager Cisco IOS file system (IFS) error tests. management Debug VLAN manager management of internal VLANs. notification Debug VLAN manager notifications.
  • Page 638 Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show vlan Displays the parameters for all configured VLANs or one VLAN (if the VLAN name or ID is specified) in the administrative domain.
  • Page 639: Debug Sw-Vlan Ifs

    Use the debug sw-vlan ifs privileged EXEC command to enable VLAN manager Cisco IOS file system (IFS) error tests. Use the no form of this command to disable debugging output. debug sw-vlan ifs {open {read | write} | read {1 | 2 | 3 | 4} | write}...
  • Page 640: Debug Sw-Vlan Notification

    Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show vlan Displays the parameters for all configured VLANs or one VLAN (if the VLAN name or ID is specified) in the administrative domain.
  • Page 641: Debug Sw-Vlan Vtp

    (Optional) Display the contents of all outgoing VTP packets that the VTP code requests the Cisco IOS VTP platform-dependent layer to send. xmit Display the contents of all outgoing VTP packets that the VTP code requests the Cisco IOS VTP platform-dependent layer to send, except for pruning packets. Defaults Debugging is disabled.
  • Page 642 Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show vtp Displays general information about VTP management domain, status, and counters.
  • Page 643: Debug Udld

    Indications of the contents of the various pieces of packets received (such as type length versions • [TLVs]) as they are examined by the packet reception code • Packet transmission attempts and the outcome Catalyst 3550 Multilayer Switch Command Reference B-47 78-11195-09...
  • Page 644 Displays information about the types of debugging that are enabled. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference for IOS Release 12.1 > Cisco IOS System Management Commands > Troubleshooting Commands. show udld Displays UDLD administrative and operational status for all ports or the specified port.
  • Page 645: I N D E X

    Layer 2 interfaces 2-98, 2-137 booting access map configuration mode 2-153 Cisco IOS image 2-26 access mode 2-461 displaying environment variables 2-231 access ports 2-461 interrupting 2-21 ACEs 2-66, 2-195 manually 2-24 Catalyst 3550 Multilayer Switch Command Reference IN-1 78-11195-09...
  • Page 646 2-54 BPDU filtering, for spanning tree 2-406, 2-438 binding to HSRP group 2-58 BPDU guard, for spanning tree 2-408, 2-438 building manually 2-54 broadcast storm control 2-451 broadcast traffic counters 2-284 Catalyst 3550 Multilayer Switch Command Reference IN-2 78-11195-09...
  • Page 647 B-27 assigning default value to incoming packets 2-165 debug port-security command B-29 assigning to Layer 2 protocol packets 2-132 debug spanning-tree backbonefast command B-33 debug spanning-tree bpdu command B-34 Catalyst 3550 Multilayer Switch Command Reference IN-3 78-11195-09...
  • Page 648 2-74 EtherChannel dot1x re-authenticate command 2-76 assigning Ethernet interface to channel group 2-27 dot1x re-authentication command 2-77 creating port-channel logical interface 2-92 dot1x reauthentication command 2-78 debug messages, display B-9, B-25 Catalyst 3550 Multilayer Switch Command Reference IN-4 78-11195-09...
  • Page 649 2-58 configuring 2-497 extended system ID for STP 2-414 IDS, using with SPAN and RSPAN 2-181 IGMP filters fallback bridging, debugging B-11 applying 2-110 fan information, displaying 2-255 debug messages, display B-16 Catalyst 3550 Multilayer Switch Command Reference IN-5 78-11195-09...
  • Page 650 2-243, 2-249 LACP Intrusion Detection System See EtherChannel See IDS lacp port-priority command 2-133 invalid GBIC lacp system-priority command 2-134 error detection for 2-85 Layer 2 mode, enabling 2-455 error recovery timer 2-87 Catalyst 3550 Multilayer Switch Command Reference IN-6 78-11195-09...
  • Page 651 B-11 macros, interface range 2-61, 2-94 debug learning on VLANs B-21 manual displaying audience aging time 2-309 purpose of 2-307 dynamic 2-313 Layer 2 multicast entries 2-317 Catalyst 3550 Multilayer Switch Command Reference IN-7 78-11195-09...
  • Page 652 2-359 2-358 interoperability 2-45 link type 2-418 configuring size 2-483 MST region displaying global setting 2-366 aborting changes mulit-VRF CE 2-423 2-125, 2-127 applying changes 2-423 multicast expansion table (MET), debugging B-23 Catalyst 3550 Multilayer Switch Command Reference IN-8 78-11195-09...
  • Page 653 2-200 nonegotiate displaying 2-346 DTP messaging policers 2-465 speed displaying 2-449 2-326, 2-327 non-IP protocols for a single class 2-196 denying for multiple classes 2-64 2-163, 2-198 forwarding policed-DSCP map 2-193 2-171 Catalyst 3550 Multilayer Switch Command Reference IN-9 78-11195-09...
  • Page 654 2-326, 2-327 port types, MVR 2-186 displaying policy maps 2-346 power information, displaying 2-255 policed-DSCP map 2-171 power inline command 2-204 setting DSCP or IP precedence values 2-219 priority-queue command 2-206 Catalyst 3550 Multilayer Switch Command Reference IN-10 78-11195-09...
  • Page 655 2-179 See STP start new 2-179 rapid PVST+ See STP rcommand command 2-207 re-authenticating 802.1X-enabled ports 2-76 sdm prefer command 2-211 secure ports, limitations 2-469 Catalyst 3550 Multilayer Switch Command Reference IN-11 78-11195-09...
  • Page 656 2-290 show tcam qos command 2-373 show ip igmp snooping command show trust command 2-291 2-490 show l2protocol-tunnel command show udld command 2-294 2-375 show l2tcam command 2-297 show version command 2-378 Catalyst 3550 Multilayer Switch Command Reference IN-12 78-11195-09...
  • Page 657 B-30 storm-control command 2-451 displaying 2-334 filter SPAN traffic 2-179 BackboneFast 2-405 sessions debug message display add interfaces to 2-179 BackboneFast events B-33 start new 2-179 MSTP B-36 spanning-tree backbonefast command 2-405 Catalyst 3550 Multilayer Switch Command Reference IN-13 78-11195-09...
  • Page 658 2-87 forward-delay time 2-446 length of listening and learning states 2-446 tail-drop shutting down Port Fast-enabled ports 2-438 assigning threshold percentages 2-543 mapping DSCPs to thresholds 2-537 Catalyst 3550 Multilayer Switch Command Reference IN-14 78-11195-09...
  • Page 659 2-509 type (boot loader) command A-23 VLAN access maps actions displaying 2-384 VLAN configuration UDLD rules 2-500, 2-505 aggressive mode 2-492, 2-494 saving 2-497, 2-507 debug messages, display B-47 enable globally 2-492 Catalyst 3550 Multilayer Switch Command Reference IN-15 78-11195-09...
  • Page 660 2-500, 2-505 2-523, 2-529 normal-range 2-497, 2-503 password 2-523, 2-527, 2-529 restarting 2-393 counters display fields 2-389 saving the configuration displaying information 2-497 2-388 shutting down 2-393 SNMP traps for VTP 2-395, 2-398 Catalyst 3550 Multilayer Switch Command Reference IN-16 78-11195-09...
  • Page 661 WRR, assigning weights to egress queues 2-533 wrr-queue bandwidth command 2-533 wrr-queue cos-map command 2-535 wrr-queue dscp-map command 2-537 wrr-queue min-reserve command 2-539 wrr-queue queue-limit command 2-540 wrr-queue random-detect max-threshold command 2-541 wrr-queue threshold command 2-543 Catalyst 3550 Multilayer Switch Command Reference IN-17 78-11195-09...
  • Page 662 Index Catalyst 3550 Multilayer Switch Command Reference IN-18 78-11195-09...

Table of Contents