Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the cabinet front (See page 4-16).
2.
Remove the pump (See page 4-48).
3.
Remove the shipping screws, if present,
that secure the motor brackets to the front
of the motor. (These shipping screws do
not need to be replaced and may not be
present if this washer has been serviced
before).
reMOve THe MOTOr
Shipping screws
4-50
4.
Remove the wire harness connector from
the motor by lifting the locking tab and pull
the harness out of the centrifugal switch.
5.
The wire harness wires must be secured
with tape in the position shown here. A wire
tie clipped closely may also be used in lieu
of electrical tape.
6.
Remove the two wire connectors from the
capacitor on the side of the motor.
Wire harness
Tape as indicated
Capacitor
Wire connectors