REPLACEMENT LEVERS
To order replacement levers, order the part
number which is metal stamped on either the lever
or the hub. Only nonsparking levers can be used
to retain the explosion-proof properties.
MOUNTING ADAPTER —15PA148-CX
Available for adapting CX to existing 2 hole
mount.
22,9
12,2
0.9
0.48
21,8
0.85
ANALOG POSITION-SENSING UNITS
1. Resistive Output
Specifications:
500 ohms ±10% in center (free position)
975 ohms max. at 105° rotation clockwise (CW)
25 ohms min. at 105° rotation CCW
2 watts power at 70°C/150°F at full scale

Wiring Diagram

ROTARY ACTUATION
Catalog Listing Prefix
11CX, 21CX, 61CX,
(*listing indicates
71CX, 81CX, 281CX,
replacement parts)
91CX*
Pretravel, max.
15°
Differential Travel,
max.
Overtravel, min.
90°
Circuitry
Single-Pole Double-
Throw
Electrical Ratings
UL/CSA Rating: L96
15 A, 120, 240, or 480
Vac.
⅛ Hp, 120 Vac; ¼ Hp,
240 Vac
0.5 A, 125 Vdc, 0.25 A,
250 Vdc.
PLUNGER ACTUATION
Catalog Listing Prefix
31CX, , 41CX,
(*listing indicates
101CX*
replacement parts)
Circuitry
Single-Pole Double-
Throw
Electrical Ratings
UL/CSA Rating: L96
15 A, 120, 240, or 480
Vac.
⅛ Hp, 120 Vac; ¼ Hp,
240 Vac
0.5 A, 125 Vdc, 0.25 A,
250 Vdc.
Pretravel, max.
Differential Travel,
max.
Overtravel, min.
Centerline of CX
104,4
Shaft
4.11
80
3.15
5/16 -18 UNC (4)
8,4
(2)
0.33
80
3.15
12CX, 22CX, 62CX,
72CX, 82CX, 282CX,
92CX*
15°
10°
90°
Single-Pole Double-
Throw
UL/CSA Rating: L23
20 A, 120, 240, or 480
Vac.
1 Hp, 120 Vac; 2 Hp, 240
Vac
0.5 A, 125 Vdc, 0.25 A,
250 Vdc.
32CX, 42CX, 102CX*
Single-Pole Double-
Throw
UL/CSA Rating: L23
20 A, 120, 240, or 480
Vac.
1 Hp, 120 Vac; 2 Hp, 240
Vac
0.5 A, 125 Vdc, 0.25 A,
250 Vdc.
2. Current Output (4 to 20 mA)
The signal from the position-sensing unit is
converted to a two-wire 4 to 20 mA current
output.
Specifications:
Voltage compliance range: 12.5 to 40 VDC
Maximum load resistance:
=
R
max
L
Current signal output: 4-20mA
Span: Adjustable from 15° to 90° of angular
rotation
Null: 4 mA position may be set at any angular
position
Typical Wiring Connections:
14CX, 24CX, 64CX,
16CX, 26CX, 66CX,
74CX, 84CX, 284CX,
76CX, 86CX, 286CX,
94CX*
96CX*
30°
30°
25°
20°
75°
75°
Double-Pole Double-
Single-Pole Double-
Throw
Throw
UL/CSA Rating: L59
UL/CSA Rating: L22
10 A, 120 or 240 Vac.
1 A, 125 Vac.
0.3 A, 125 Vdc, 0.15 A,
250 Vdc.
36CX, 46CX, 106CX*
Single-Pole Double-
Throw
UL/CSA Rating: L22
1 A, 125 Vac.
2,5 mm [0.10 in]
1 mm [0.04 in]
2 mm [0.08 in]
4,75 mm [0.19 in]
Honeywell • Sensing and Control 3
PK 88136
ISSUE 4
V
Supply
12.5
20
mA
1172CX, 2172CX,
9172CX*
15°
90°
(Gold Contact) Single-
Pole Double-Throw
UL/CSA Rating: L22
1 A, 125 Vac
3172CX
(Gold Contact) Single-
Pole Double-Throw
UL/CSA Rating: L22
1 A, 125 Vac
1 mm [0.04 in]

Advertisement

loading

This manual is also suitable for:

11cx81cx281cx21cx61cx71cx ... Show all