Table Of Error Codes - Brother BAS-326G Service Manual

Direct drive programmable electronuc pattern sewer
Hide thumbs Also See for BAS-326G:
Table of Contents

Advertisement

9. TABLE OF ERROR CODES

Wait at least 5 minutes after turning off the power switch and disconnecting the power cord from the wall outlet
before opening the cover of the control box. Touching areas where high voltages are present can result in severe
injury.
If a malfunction should occur with the sewing machine, a buzzer will sound and an error code will appear in the display
window. Follow the remedy procedure to eliminate the cause of the problem.
Switch-related errors
Code
Stop switch was pressed. Press the RESET key to clear the error.
E010
Stop switch was pressed. Press the RESET key to clear the error.
E011
Press the
The stop switch was still being pressed, or there is a problem with the stop switch connection.
E015
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
Problem with the stop switch connection.
E016
Turn off the power, and then check that connector P13 on the main P.C. board is properly connected.
Foot switch is depressed to the 2nd step. (If using a two-pedal foot switch, the power was turned on while the
start switch was still depressed, or the start switch was pressed without the work clamp being lowered.)
E025
Turn off the power and check the foot switch.
Foot switch is depressed to the 1st step. (Work clamp switch if using a two-pedal foot switch)
E035
Turn off the power and check the foot switch.
Work clamp motions are not set correctly.
E036
Set memory switch No. 050 or 003 correctly in accordance with the type of foot switch being used.
Machine head tilting was detected after the power was turned on.
Turn off the power, and then return the machine head to its original position.
E050
Check that connector P9 on the main P.C. board is properly connected.
Machine head tilting was detected while the sewing machine was operating.
E051
Turn off the power, and then check that connector P9 on the main P.C. board is properly connected.
Machine head tilting was detected when the power was turned on.
Turn off the power, and then return the machine head to its original position.
E055
Check that connector P9 on the main P.C. board is properly connected.
An operation panel key was still being pressed when the power was turned on, or key is faulty.
E065
Turn off the power and check the operation panel.
key to move the feed mechanism so that you can continue sewing.
DANGER
Cause and remedy
BAS-311G, BAS-326G
9. TABLE OF ERROR CODES