Service Specifications - Craftsman 390.30479 Owner's Manual

Submersible sump pump
Table of Contents

Advertisement

SERVICE / SPECIFICATIONS
General
[AWARNING]RJsk of electric
shock.
When
servicing
pump
always
disconnect
power
to electrical
outlet
and remove
pump
electric
cord fi'om outlet.
1. if'pump does not operate:
a. Check for loose plug at electric outlet.
b. Check for blown fuses or tripped circuit breakers
at
fuse box/(trcult
breaker box.
c. Be sure nothing
interferes
with action of automatic
float switch.
d. If a, b, and c above check
OK, plug in a Eght that you
know
works.
If it lights, take your pump
to Sears for
service.
If it doesn't
light, the electrical
circuit
is faulty;
consult
a licensed
electrician.
2. Pump
starts, but blows
fuses/trips
circuit
breakers:
After disconnecting
power
to pump,
remove
the screen
and shield from
the bottom
of the pump
and make sure
that the impeUer
turns
freely.
Remove
any debris
ob-
structing
impeller.
If pump
still does not operate
cor-
rectly, return
it to your nearest
Sears Service Department
for repairs.
3. Pump
runs, but does not empty
sump:
a. Clean pump
intake
screen.
b. Water
may be entering
sump faster than the pump
can
discharge
it.
c. Be sure vertical
distance
from
pump
discharge
outlet
to discharge
pipe
outlet
does not exceed
maximum
vertical
pumping
distance
shown
in "Specifications,"
below.
d. Be sure discharge pipe is not plugged or frozen.
TEATHERED
SWITCH
REPLACEMENT
NOTICE:
Teathered
float must be able to swing through
its
complete
arc without
interference
from
sidewall
of sump,
plumbing
or any other
object.
1. Remove
pump
power
cord from switch
plug.
2. Remove
tether
clamp
screw
and slide cord from clamp.
3. Insert new
cord
in tether
clamp.
Put the clamp
at the
same distance
from the float that it was on the old switch.
4. Tighten
tether
clamp
screw.
5. Check
sump pump
operation
by fiUing sump with water
and observing
operation
through
one complete
cycle.
_
Failure
to check
installation
with
water
in sump
can lead to improper
operation,
premature
pump
failure
and flooding.
Stock
Maximum
Number
HP
Amps
3050
1/2
7.6
30479
1/3
9.8
3O579
1/2
12.0
SPECIFICATIONS
Dimensions in inches (mm)
Length
Width
Height
9" (229)
6-1/2" (165)
11-1/2" (292)
9,-3/4"(248) 7-5/16" (186) 11-1/2" (292)
9-3/4" (248) 7-5/16" (186) 11-1/2" (292)
GPM (L/rain.) at Vertical Pumping Distance in Feet (M)
5' (1.6)
10' (3)
15' (4.6)
20' (6.1)
25' (7,6)
61(231)
56(212)
50(189)
46(174)
43(163)
48(182)
39(148)
29(110)
16(61)
62(235)
53(200)
46(174)
38(144)
26(98)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

390.305001390.30579390.304790390.305790

Table of Contents