Pedestal sump pump

Advertisement

4
This
punlp
is reconlnl(-nded
|])r
use
in
permanent
instal-
lations
Ol__ly. Do
not
it_istal[
or1 clay,
earth,
or sand
surfaces
J_.CAUTION i Punq) must bc level (column
most be verti-
cal) when
operating.
If motor
is tilted,
internal
start/run
switch
lilly
overheat
and
daluage
i11otor.
ADDITIONAL
INSTALLATION
MATERIALS
Sump/Utility Puml_ Hose Kit, SEARS Stock No. 27909, con-
taioing 24' of 1-1/4" flexible plastic pipe, a 1-1/4" plastic
adapter and a stainless steel clamp.
Cbeck Valve, SEARS Stock No. 2789 or 2792.
THE
SUMP
Tbe sump
should
be located
at tile lowest
place
in tim base-
ment or area to be drained.
Floor drains
from other
areas in
the basement
may bc tiled into tile sump.
Drain tile around
a house
foundation
can also be tiled into the sump,
effec-
tively removing
water
and relieving
pressure
from this area.
A suitable
sump
can be a 2(1" or 24" sewer
tile. Sump must
be at least 12" in diameter.
A sump cover is desirable to exclude refuse from the sump.
Consult local code for sump cover specifications.
SPECIFICATIONS
Power
supply
required
....................................
115V, 60 HZ.
Horsepower
(390.303302)
.............................................
1/3
Horsepower
(390.303491)
.............................................
1/2
Motor duty .........................................................
Intermittent
Liquid Temp.
Range ........................
32 ° F to 70 ° F (0°-21°C)
Individual
Branch
Circuit
Requirement
GFCI Class A ......................................
15 Amps
Motor full load (maximum
- 390.3(13302)
............. 3.5 Amps
Motor
full load (maximum
- 390.303491)
............
7.3 Amps
Discharge
(390.303302)
......................................
1-1/4" NPT
_iscbarge
(390.303491)
......................................
1-1/2" NPT
PUMP
INSTALLATION
Check your local Electrical and Plumbing ('odes before in-
stalling pump. You
nlust
comply
with their rules.
Set tile pump
on
the bottom of the
stlnlp,
luakiug
sure
that
it sits solidly
and
is level.
Be sure
there
is cnotlgh
space
arottlld
the
punlp
to allow
tile s\vitc]l
I'ree MOVelncnt
as
tile stlnlp
veater
level
cllallgCS
I)o not Jllstall
un
clay,
earth,
or salld
_" CAUTION
Risk of flooding.
If a flexible
discharge
hose
is used,
pump
may move
around
in sump
when
motor
starts.
If it moves
far enough
so that the
switcb
bits the side of the sump,
the switch
may stick and
prevent
pump
fi'om starting.
Make sure that pump
is se-
cured
so tbat it cannot
"walk around"
in sump.
NOTE: To avoid backflow
into tile sump when the pump
shuts off, install a Check Valve, SEARSStock No. 2789, in the
threaded discharge port of pump (390.303302) or l-1/2"xl-
1/4" reducer bushing (390.303491 ). Reducer bushing is in-
cluded with Model 390.303491.
Be sure arrow on check
valve body points away from the pump. This Check Valve is
equipped
with an air bleed hole to prevent airlocking the
pump. If using any other check valve, drill 1/8" (3.2 ram)
hole in discharge
pipe just above pump body but below
check valve to prevent air locks.
Use 1-1/4" plastic pipe from Hose Kit No. 27909 for the dis-
charge pipe. Run the discharge
pipe to the nearest sewer
outlet or other point of disposal. Use the most direct route
with the fewest turns and elbows possible.
Use Teflon tape to seal threads in plastic pipe. Hand tighten
only.
SumpCover
1/4"
!
_
Sewer Tile
/
12' Min
'
' '
';;
Concrete
BasementFloor
Figure
I