TS86A POWERPILE
®
3. Turn the dial to a low setting so that the thermostat
loses the heat it has gained from your hands. Wait
at least five minutes.
4. Slowly turn the dial until the pointers read the same.
5. Firmly hold the dial from turning and carefully turn
the hex nut counterclockwise
just slips to the heating contact end of tube but
no farther.
6. Recheck calibration, select the desired temperature,
and replace the cover.
Automation and Control Solutions
Honeywell Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
69-0153—3
69-0153—3 J.H. Rev. 9-95
THERMOSTAT
until the mercury
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
After the installation is complete, the homeowner can paint
the TS86 cover to match the room decor. Remove
thermostat cover ring to paint. Be careful not to damage or
splash paint on working parts.