 Start the datalogger server on the UDP port configured using the datalogger.exe using the command prompt on
Windows. Alternatively, the Python script datalogger.py can be used to start the server (please refer to section 3.4 for
the python installation). The arguments of the server call are as follows:
datalogger.exe server [-h] [-i SERVER_IP] [-p SERVER_PORT] [-t TIMEOUT] [-f
{pandas,csv,hdf,xlsx,json,msgpack,parquet}] [-o OUTPUT] [-c OFFSET]
or
python datalogger.py server [-h] [-i SERVER_IP] [-p SERVER_PORT] [-t TIMEOUT] [-f
{pandas,csv,hdf,xlsx,json,msgpack,parquet}] [-o OUTPUT] [-c OFFSET]
Optional arguments:
-h, --help
-i SERVER_IP , --ip SERVER_IP
-p SERVER_PORT, --port SERVER_PORT
-t TIMEOUT, --timeout TIMEOUT
-f {pandas,csv,hdf,xlsx,json,msgpack,parquet}, --format
{pandas,csv,hdf,xlsx,json,msgpack,parquet}
-o OUTPUT, --output OUTPUT
--overwrite
-c OFFSET,--temperature_correction OFFSET
 Press button 1 on XDK within the configured timeout interval to start logging.
 Data will now be saved as .bin file on computer.
 Press button 1 again to stop logging. When stopped, the server will convert the .bin file to defined format: .csv (default),
pandas, hdf xlsx, json, msgpack, or parquet.
For explanation on the file content, see Table 9.
The XDL120 also supports to stream data via Enterprise WPA2 WLAN network for increased security. To enable WPA2
Enterprise connection and communication, make sure that in the wlan.txt file WLAN_ENTERPRISE and
WLAN_SERVICEPACK_UPDATE are set to true apart from providing the right credentials for WLAN_SSID,
WLAN_USERNAME and WLAN_PASSWORD. Please be aware that making the WLAN_SERVICEPACK_UPDATE as true is a
pre-requisite for any bare-metal XDK to support Enterprise WPA2 connection and leaving this as true will update the
WiFi chip every single time it boots. Therefore, it is advised that the user should set WLAN_SERVICEPACK_UPDATE to
false after the first time (for example, while re-using the data logger application or after ~one minute since the first device
boot-up). After this, follow the same steps that were mentioned before.
Data subj ect to change without notice
show this help message and exit
The IP address of the interface connected to the
network the XDK is on. IPv4 only. Default is 0.0.0.0
(listen on all interfaces).
The port the datalogger should listen on. Defaults
to 6666.
Timeout in seconds to wait for a connection.
Default is 120s.
List of available format to convert the bin file.
Default is csv.
Target file name. Default is 'WLAN_Data_Log'
Overwrite bin file and all files produced conversion
if they exist. Default is to prompt if bin file exist.
Will not check if files exist before conversion.
Temperature correction factor. Default is -2.1K.
See section 3.8 for details.