Bosch XDL120 User Manual page 13

Data logger/ data streamer for xdk110
Table of Contents

Advertisement

XDL120 | User Manual
<rep_xy>
Repetitions on
X and Y axes
<rep_z>
Repetitions on
the Z axis
Sensor
Tag in XML
parameter
file
Bandwidth
<accel_bw>
<accel_range> 2G
Range
Sensor
Tag in XML file
parameter
Output Data
<odr>
Rate
<power_mode>
Power Mode
<standby_dur>
Standby
Duration
<filter_coeff>
Filter
Coefficient
Data subj ect to change without notice
08 Hz
0x03
15 Hz
0x04
20 Hz
0x05
25 Hz
0x06
30 Hz
0x07
rep_xy
repetitions X and Y
nXY = 1 + 2 * repXY
Repetitions Z
nZ = 1 + repZ
Table 5: Sensor parameters for BMA280
Possible
XML hex
setting
value
7.81 Hz
0x00
15.63 Hz
0x01
31.25 Hz
0x02
62.50 Hz
0x03
125 Hz
0x04
250 Hz
0x05
500 Hz
0x06
0x00
4G
0x01
8G
0x02
16G
0x03
Table 6: Sensor parameters for BME280
Possible setting
0.1 Hz,
0.2 Hz,
....,
25 Hz
SLEEP_MODE
FORCED_MODE
NORMAL_MODE
1MS
63MS
125MS
250MS
500MS
1000MS
2000MS
4000MS
COEFF_OFF
COEFF_2
COEFF_4
COEFF_8
COEFF_16
Repetitions are the number of measured
points to generate one sample, the more
repetitions the higher the measurement
accuracy.
Related to Z-Axis
Notes
Bandwidth parameter is used to set the output data
rate of the acceleration sensor.
XML
Notes
hex
value
0x00,
Output data rate setting resolution
0x01,
of 0.1 Hz.
....
0xf9
0x00
The environmental sensor can
0x01
operate in three different modes:
sleep, forced and normal.
0x03
0x00
The standby duration is the amount
0x01
of time the sensor is in idle state.
0x02
The possible standby times range
0x03
from 1ms to 4 s.
0x04
Note: The measurement rate
0x05
in normal mode depends on
0x06
the measurement time and
0x07
the standby time
0x00
Controls the time constant of the
0x01
filter.
0x02
0x03
The response time depends on the
0x04
filter coefficient selected.
Note: The number of samples will
increase if the
13 | 25
Bosch Connected Devi ces and Sol utions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents