7-2. Room Temperature Sensor Setting

The room temperature sensors are built into the indoor
unit and the wireless remote controller. Either of these
room temperature sensors can operate.
The system is shipped from the factory set to the
indoor unit sensor. To switch to the remote controller
sensor, press the sensor switching button located
inside the remote controller cover and check that A/C
SENSOR on the LCD display panel goes out.
NOTE
If the sensor switch is set to the remote controller side,
but no room temperature data is sent to the main unit
for 10 minutes, the sensor is automatically switched to
the indoor unit side. As much as possible, install the
remote controller facing the unit.

7-3. Address Switches

If you are installing more than 1 indoor unit (up to 6) in
the same room, it is necessary for you to assign each
unit its own address so they each can be operated by
their remote controller.
Up to 6 indoor units can be controlled separately
through the address switches. The operating control
has the reception address switch and the remote
controller has the transmission address switch. This
function is utilized by matching the transmission and
reception address switches.
Remote controller
address display
Address switch
positions

7-4. Setting the Model Code

Flap display selector switch
1
Make the slide switch settings in the battery compartment box of the remote controller depending on the type
of indoor unit in which the wireless receiving unit is used.
2
Operation mode switch
In this Split System Air Conditioner set the switch to "A".
* The switch is factory set to "S" / "A".
* Always press the reset button after switching the setting.
S
K
N
A
H
Fig. 7-4
Page 69
ADR
ADR
* Any address
1 2 3
switch position
4 5 6
available
C
2
Operation
1
mode switch
1
Flap display
2
selector switch
SET
CL
ADR
1 2 3
4 5 6
S
K
N
S
X, T type
K type
A
H
C
A
Heat pump with
Heat pump without
Auto mode (CH type)
Auto mode
69
ADR
ACL
SENSOR
Sensor button
Fig. 7-3
ADR
1 2 3
4 5 6
K
N
S
K
N
U type
H
C
A
H
C
Cooling only
RC
(WL)