Powering On - Fujitsu ETERNUS DX60 S3 Operation Manual

Hybrid storage systems
Hide thumbs Also See for ETERNUS DX60 S3:
Table of Contents

Advertisement

2.
Basic Operation
Powering On and Off

Powering On

This section explains how to turn on the ETERNUS DX.
To turn on the ETERNUS DX, perform the following procedure.
Via the power switch
Press the Power switch to turn on the ETERNUS DX.
The following methods can be used to turn the power on by linking with the server.
Power Synchronized Unit
Use the power synchronized unit to turn on the ETERNUS DX.
Wake On LAN
Use the Wake On LAN function to turn on the power.
Before turning on the ETERNUS DX, make sure that the main line switches of the power distribution units and
the PSU switches on the power supply units of the ETERNUS DX are "ON". Do not turn the main line switches of
the power distribution units and the PSU switches on the ETERNUS DX to the OFF position.
After turning the power on, it takes approximately five minutes for the ETERNUS DX to reach the READY
state (the READY LED turns on). If an error is detected in a component during the initial power-on diagnos-
tics, it may take up to 10 minutes for the ETERNUS DX to reach the READY state. This should be taken into
consideration for scheduled operations.
Before turning the server on, check that the ETERNUS DX and the network devices that connect the ETER-
NUS DX and the server are all in READY status.
If the server is turned on while any of these devices are not in READY status, the server may not be able to
recognize the ETERNUS DX.
To turn on the ETERNUS DX by linking with the server, the server must wait until the ETERNUS DX is in the
READY state.
If the Auto Power function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is automatical-
ly turned on when power is supplied to the ETERNUS DX.
If the Power Resume function is enabled via ETERNUS Web GUI or ETERNUS CLI, the ETERNUS DX is automat-
ically turned on after the power is restored.
After power-off, wait for about one minute before turning power on again.
If the ETERNUS DX is not turned off normally due to problems such as a power failure, it takes approximate-
ly five minutes (max.) longer to reach the READY state the next time the ETERNUS DX is turned on.
This section explains how to use the Power switch to turn on the ETERNUS DX.
For other procedures, refer to the related manuals.
FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Operation Guide (Basic)