Specifications
Detection range
Life
Alarm Setpoints
Sensor Type
Waterproof
Shop for Gas products online at:
H
S
0 to 100.0 ppm with 1/0.1 increments
2
CO
0 to 1000 ppm with 1 increments
O
0 to 25.0% Vol with 0.1 increments
2
Combustible gases 0 to 100% LEL (or 0 to 5.0% Vol) with 1 increments
Shelf Life
Six (6) months before activation
Maximum operating life 2 years after activation, assuming 2 minutes of alarm time per day.
Event Logging
Maximum 70 Events
Use Fleet Manager II via an IntelliDoX station to adjust alarm setpoints.
For more information, refer to the operator manuals for Fleet Manager II
software or more and the IntelliDoX automatic test and calibration sta-
tion.
Audible alarm ≈ 95 dB at 30 cm (1 ft.)
Visual alarm
Flashing, wide-angled alarm lens with red LEDs plus alarm LCD readout
Display
Alphanumeric liquid crystal display (LCD)
H
S and CO
Single plug-in electrochemical cell
2
O
Lead oxide
2
Combustibles (LEL) LED Infrared
Battery
Lithium, non-replaceable
Identification code for protection
CanarySense
www.
IP68
.com
26