Pair, Group Name Differences In Cci And Navigator 2 - Hitachi AMS2100 User Manual

Ams 2000 family copy-on-write snapshot
Hide thumbs Also See for AMS2100:
Table of Contents

Advertisement

C:\HORCM\etc>pairdisplay -g VG01
group
PairVOL(L/R) (Port#,TID,LU-M) ,Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# M
VG01
oradb1(L)
VG01
oradb1(R)
VG01
oradb2(L)
VG01
oradb2(R)
VG01
oradb3(L)
VG01
oradb3(R)
C:\HORCM\etc>pairsplit -S -g VG01 -d oradb1
C:\HORCM\etc>pairdisplay -g VG01
group
PairVOL(L/R) (Port#,TID,LU-M) ,Seq#,LDEV#.P/S,Status, Seq#,P-LDEV# M
VG01
oradb1(L)
VG01
oradb1(R)
VG01
oradb2(L)
VG01
oradb2(R)
VG01
oradb3(L)
VG01
oradb3(R)

Pair, group name differences in CCI and Navigator 2

C-14
Hitachi AMS 2000 Family Copy-on-Write SnapShot User Guide
In the examples below, the group name in the configuration
definition file is VG01.
1. Execute the pairdisplay command to verify that the status of
the SnapShot pair is PSUS or PSUE. For example:
(CL1-A , 1,
2-0 )8100012385000123
(CL1-A , 1,
3-0 )8100012385000123
(CL1-A , 1,
2-1 )8100012385000123
(CL1-A , 1,
4-0 )8100012385000123
(CL1-A , 1,
2-2 )8100012385000123
(CL1-A , 1,
5-0 )8100012385000123
2. Execute the pairsplit -S command to release the SnapShot
pair. For example:
3. Execute the pairdisplay command to verify that the pair status
changed to SMPL. For example:
(CL1-A , 1,
2-0 )8100012385000123
(CL1-A , 1,
3-0 )8100012385000123
(CL1-A , 1,
2-1 )8100012385000123
(CL1-A , 1,
4-0 )8100012385000123
(CL1-A , 1,
2-2 )8100012385000123
(CL1-A , 1,
5-0 )8100012385000123
Pairs and groups that were created using CCI will be displayed
differently when status is confirmed in Navigator 2.
Pairs created with CCI and defined in the configuration definition
file display unnamed in Navigator 2.
Groups defined in the configuration definition file are also
different tin Navigator 2.
Pairs defined in a group on the configuration definition file using
CCI are displayed in Navigator 2 as ungrouped.
For information about how to manage a group defined on the
configuration definition file as a CTG, see the Hitachi Adaptable
Modular Storage Command Control Interface (CCI) Reference Guide.
Operations using CCI
2.P-VOL PSUS,-----
---- -
3.S-VOL SSUS,-----
---- -
2.SMPL ----,-----
---- -
4.SMPL ----,-----
---- -
2.SMPL ----,-----
---- -
5.SMPL ----,-----
---- -
2.SMPL ----,-----
3.SMPL ----,-----
2.SMPL ----,-----
4.SMPL ----,-----
2.SMPL ----,-----
5.SMPL ----,-----
---- -
---- -
---- -
---- -
---- -
---- -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ams2300Ams 2500

Table of Contents