Honeywell T6 Pro Installation Instructions Manual page 9

Table of Contents

Advertisement

Advanced setup options (ISU)
# ISU
ISU Name
221
Heat Stages / Backup Heat Stages
230
Fan Control in Heat
253
Aux/E terminal control (Fixed to
"0" setting on all models except
TH6320U)
255
Backup Heat Source
(Heat Pump Only)
(TH6320U / TH6220U only)
256
Emergency Heat Source (TH6320U
only)
260
External Fossil Fuel Kit
(TH6320U / TH6220U only)
300
System Changeover
303
Auto Changeover Differential
340
Backup Heat Droop
350
Upstage Timer for Backup Heat
355
Compressor Lockout / Balance Point
356
Outdoor Lockout Backup Heat
365
Compressor Cycle Rate (Stage 1)
366
Compressor Cycle Rate (Stage 1)
370
Heating Cycle Rate (Stage 1)
371
Heating Cycle Rate (Stage 2)
375
Heating Cycle Rate Auxiliary Heat
378
Heating Cycle Rate Emergency Heat
(TH6320U only)
ISU Options (factory default in bold)
Heat Stages: 1, 2
Backup Heat Stages: 0, 1
1 = Equipment Controls Fan
2 = Thermostat Controls Fan
0 = Drive both Aux & E together
1 = Aux and E independent
1 = Electric Forced Air
2 = Gas/Oil Forced Air (or Fossil Forced Air)
1 = Electric Forced Air
2 = Gas/Oil Forced Air (or Fossil Forced Air)
0 = Thermostat Controls Backup Heat
1 = External Fossil Fuel Kit Controls Backup Heat
0 = Manual
1 = Automatic
0 °F to 5 °F
0.0 °C to 2.5 °C
Note: Differential is NOT deadband. Honeywell uses an advanced algorithm that
fixes deadband at 0 °F. The differential setting is the minimum number of degrees
from set-point needed to switch from the last mode running (heat or cool) to the
opposite mode when the thermostat is in auto-changeover. This is more advanced
than previous thermostats.
0 = Comfort
2 = 2 °F
3 = 3 °F
4 = 4 °F
5 = 5 °F
6 = 6 °F
7 = 7 °F
8 = 8 °F
Note: 0 (comfort) setting only available if backup heat (ISU 255) is set to electric.
0 = Off
1 = 30 minutes
2 = 45 minutes
3 = 60 minutes
4 = 75 minutes
5 = 90 minutes
6 = 2 hours
7 = 3 hours
-- = Off
5 °F to 60 °F (in 5 °F increments)
-15.0 °C to 15.5 °C (in 2.5 °C or 3.0 °C increments)
Note: Use a wired sensor to set compressor lockout / balance point on TH6320U
/ TH6220U.
-- = Off
5 °F to 65 °F (in 5 °F increments)
-15.0 °C to 18.5 °C (in 2.5 °C or 3.0 °C increments)
1 - 6
1 - 6
1 - 12
1 - 12
1 - 12
1 - 12
9
9 = 9 °F
10 = 10 °F
11 = 11 °F
12 = 12 °F
13 = 13 °F
14 = 14 °F
15 = 15 °F
8 = 4 hours
9 = 5 hours
10 = 6 hours
11 = 8 hours
12 = 10 hours
13 = 12 hours
14 = 14 hours
16 = 16 hours

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents