Epson RC180 Manual page 95

Robot controller
Hide thumbs Also See for RC180:
Table of Contents

Advertisement

LED Description of DeviceNet
LED status represents the status of the fieldbus board.
GRN
RED
Board Installation of DeviceNet
Set the baud rates between the MAC address of the device and the master by setting the
DeviceNet board configure switch.
(1) Set the MAC address for DeviceNet board by setting the configure switch. Make
(2) Set the DeviceNet baud rate. Check the master configuration and set the same baud
RC180 Rev.17
LED status
Communication power supply OFF
OFF
Disconnected
Link OK
ON
Online connected
Blinking
Online disconnected
ON
Link error
Blinking
Communication time out
sure that the MAC address is different from the other devices in the network. Refer
to the following table for the configuration.
MAC address
0
1
2
3
. .
.
62
63
(at shipment)
rate. Refer to the following table for configuration settings.
Baud Rate
125 K
250 K
500 K
Configuration prohibited
Setup & Operation 12. Option Units
NS
sw3
sw4
sw5
(MSB)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
Switch
sw1
sw2
OFF
OFF
OFF
ON
ON
OFF
ON
ON
MS
Device power supply OFF
Device operating
Data size error
Critical error
Error
Switch
sw6
sw7
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
sw8
(LSB)
OFF
ON
OFF
ON
OFF
OFF
ON