G0673 440V
Conversion
The Model G0673 can be converted for 440V
operation. This conversion job consists of dis-
connecting the machine from the power source,
changing the connections on the magnetic switch
and rewiring the motor for 440V operation.
The Model G0673 440V Conversion Kit (Part
#P0673036) for this procedure can be purchased
by calling Grizzly Customer Service at (800) 523-
4777.
All wiring changes must be performed by an elec-
trician or qualified service personnel before the
machine is connected to the power source. If, at
any time during this procedure you need help, call
Grizzly Tech Support at (570) 546-9663.
To rewire the Model G0673 for 440V operation:
1.
DISCONNECT MACHINE FROM POWER!
2.
Remove the magnetic switch cover, then
disconnect and remove the 220V magnetic
switch (see Figure 2).
Figure 2. 220V magnetic switch.
-18-
3.
Install the 440V magnetic switch and wire it
according to the G0673 Wiring Diagram on
Page 45.
4.
Remove the motor junction box cover, rewire
the motor as shown on the diagram located
inside the junction box, then re-install the
cover.
Note: The reference motor wiring diagram on
Page 45 was current at the time of printing,
but always use the wiring diagram provided
inside the motor junction box, as it will reflect
any changes to the motor shipped with your
machine.
Model G0671/G0672/G0673 (Mfd. Since 6/17)