Product Selection Guide; Electrical Specifications - GE 429CT Installation Instructions And Use

Esl 429/449 series self-diagnostic photoelectric smoke detectors

Advertisement

Product Selection Guide

Model Designator
Series
Features
Designator
449CSRT
Wire Type
Power Designator
Features
Designator
Feature
E
End-of-Line Power
Supervisory and
Sensitivity Status
Relay
H
Isolated Fixed Temp.
and Rate-of-Rise
Heat Detector
R
Auxiliary Relay
S
Built-in Sounder
T
Integrated Fixed Temp.
and Rate-of-Rise
Heat Detector

Electrical Specifications

Model
2-Wire 4-Wire Min.Volt. Max.Volt. Max. Ripple
429AT
*
429C
*
429CT
*
429CRT
*
429CST
*
449C
449CT
449CRT
449AT
449CST
449CSRT
449CSRH **
449CSTE
449CTE
Power Supervision Units
Model
204-6V (UL Listed)
204-12/24V (UL Listed)
Accessories
SM-200
Smoke! in a can
SM-EXT1
Smoke! in a can
211
Replacement optical blocks (set of 10)
241
Terminal block for 4-wire smoke detectors 449CTE, 449CSTE, 449AT, 449C, 449CT,449CST
* 429 models draw up to a maximum of 60mA current if not limited by panel.
** 449CSRH model is a smoke alarm with isolated heat detector.
Certain items in the installation instructions are protected under one or more of the following patents: 5,546,074; 5,798,701; 5,821,666;
6,756,906
Specifications
Operating temperature ................... ...32°F to 100°F (0°C to 38°C)
Operating humidity range ....................... 0 to 95% non-condensing
Sounder specifications ............................................ 85dB at 10 feet
Field wiring size ............................................................ 14-24 AWG
Self-diagnostic indication .................. typically 27 hours after reset
(do not connect power supply that resets every 24 hours)
Wire Type
Number
2
4
Description
Built-in end-of-line relay that also acts as a sensitivity status output. For four-wire only. Fail-safe
relay trips upon loss of power or if smoke detector is outside the approved sensitivity range for
more than one day. End-of-line resistor is easily connected to terminal with no extra wiring, or
relay contacts can be connected to a separate trouble loop.
Isolated fixed 135°F (57°C) and rate-of-rise heat detector, independently trips the LED and alarm
relay output. Smoke detector activates internal sounder (local alarm) and auxiliary relay, but does
not latch. Approved as both single station smoke alarm and system heat detector.
Used to activate other devices such as elevator recall, door holders, etc. UL Listed for releasing services.
85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed.
Integrated fixed 135°F (57°C) temp. and rate-of-rise heat detector offers double protection.
Either heat detector or smoke detector can trip and latch LED and alarm relay outputs.
(PK to PK)
(V)
6.5
20
10%
8.5
33
10%
8.5
33
10%
8.5
33
10%
8.5
33
10%
*
8.5
33
10%
*
8.5
33
10%
*
8.5
33
10%
*
5.1
27
10%
*
8.5
33
10%
*
8.5
33
10%
*
8.5
33
10%
*
8.5
33
10%
*
8.5
33
10%
Min.Volt.
Max. Volt.
Typ. Avg. Stby.Cur.(uA)
5.1
15
33mA @ 6VDC
8.5
33
14mA @ 12VDC, 28mA @ 24VDC
canned smoke for functional testing of smoke detectors
®
extension accessory
®
GE Security
12345 SW Leveton Drive
Tualatin, OR 97062
503-692-4052
Model Designator
Description
Designator
Two-wire only
9
Four-wire only
Typ.Avg.Stby. Typ. Alarm Cur. Typ.Avg. Pol. Alarm Relay Other Relay
Cur. (12-24V)
(12-24V)
(uA)
(mA)
70
*see S09A
70
*see S10A
70
*see S10A
70
*see S11A
70
*see S11A
70
15
70
15
70
31
70
15
70
40
70
51
70
51
23mA
51
23mA
31
Heat detector .................. fixed temp 135°F, 50 foot (15m) spacing
rate-of-rise 15°F/min > 105°F (8°C/min > 41°C)
Auxiliary relay contacts ........ 2A @ 28VDC or 120VAC (resistive)
Alarm contacts .................................. 500mA @ 36VDC (resistive)
Dimensions ................. 6.1" (15.5cm) diameter x 1.9" (4.7cm) deep
Weight ..................................................................... 8.8 oz. (0.25kg)
Color ....................................................................................... white
USA & Canada: 800-547-2556
Tech Support: 800-648-7424
www.ge-security.com
14153D / September 2004
Power Designator
Listing
Designator
Power
UL
A
6/12 VDC
C
12/24 VDC
Rev.Cur.
Contacts
(mA)
(A)
-
-
-
-
-
-
-
-
10
-
-
0.5
-
0.5
-
0.5
-
0.5
10
0.5
10
0.5
10
0.5
33
0.5
23
0.5
Relay Contacts (A)
0.5
0.5
Contacts
(A)
-
-
-
2
-
-
-
-
-
-
2
2
2
2